These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 8448863)

  • 1. Clinical measurement of serum amiodarone and desethylamiodarone by using solid-phase extraction followed by HPLC with a high-carbon reversed-phase column.
    Jandreski MA; Vanderslice WE
    Clin Chem; 1993 Mar; 39(3):496-500. PubMed ID: 8448863
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simplified liquid-chromatographic assay of amiodarone and desethylamiodarone after solid-phase extraction.
    Pollak PT; Carruthers SG; Freeman DJ
    Clin Chem; 1986 May; 32(5):890-3. PubMed ID: 3698284
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of amiodarone and its metabolite desethylamiodarone in human plasma and serum.
    Paczkowski D; Popławska W; Filipek M; Podleśny J
    Pol J Pharmacol Pharm; 1989; 41(4):359-67. PubMed ID: 2634829
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Liquid-chromatographic determination of amiodarone and N-desethylamiodarone in serum.
    Ou CN; Rognerud CL; Duong LT; Frawley VL
    Clin Chem; 1990 Mar; 36(3):532-4. PubMed ID: 2311227
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Microassay of amiodarone and desethylamiodarone in serum by capillary electrophoresis with head-column field-amplified sample stacking.
    Zhang CX; Aebi Y; Thormann W
    Clin Chem; 1996 Nov; 42(11):1805-11. PubMed ID: 8906080
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement of serum amiodarone and desethylamiodarone by HPLC: its usefulness in the follow-up of arrhythmic patients treated with amiodarone.
    Manfredi C; Clerico A; Iervasi G; Turchi S; Cazzuola F; Berti S; Sabatino L; Biagini A
    Int J Clin Pharmacol Res; 1995; 15(2):87-93. PubMed ID: 8593976
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of amiodarone and desethylamiodarone in human plasma by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry with an ion trap detector.
    Kollroser M; Schober C
    J Chromatogr B Analyt Technol Biomed Life Sci; 2002 Jan; 766(2):219-26. PubMed ID: 11824809
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Application of the Empore solid-phase extraction membrane to the isolation of drugs from blood. I. Amiodarone and desethylamiodarone.
    Lensmeyer GL; Wiebe DA; Doran T
    Ther Drug Monit; 1991 May; 13(3):244-50. PubMed ID: 1926279
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of amiodarone and desethylamiodarone in horse plasma and urine by high-performance liquid chromatography combined with UV detection and electrospray ionization mass spectrometry.
    Maes A; Baert K; Croubels S; De Clercq D; van Loon G; Deprez P; De Backer P
    J Chromatogr B Analyt Technol Biomed Life Sci; 2006 May; 836(1-2):47-56. PubMed ID: 16616880
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A rapid procedure for the monitoring of amiodarone and N-desethylamiodarone by HPLC-UV detection.
    Juenke JM; Brown PI; McMillin GA; Urry FM
    J Anal Toxicol; 2004; 28(1):63-6. PubMed ID: 14987427
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Simultaneous measurement of amiodarone and desethylamiodarone in human plasma and serum by stable isotope dilution liquid chromatography-tandem mass spectrometry assay.
    Kuhn J; Götting C; Kleesiek K
    J Pharm Biomed Anal; 2010 Jan; 51(1):210-6. PubMed ID: 19720490
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Simultaneous determination of amiodarone and its metabolite desethylamiodarone by high-performance liquid chromatography with chemiluminescent detection.
    Pérez-Ruiz T; Martínez-Lozano C; García-Martínez MD
    Anal Chim Acta; 2008 Aug; 623(1):89-95. PubMed ID: 18611462
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A rapid HPLC method for the simultaneous determination of amiodarone and its major metabolite in rat plasma and tissues: a useful tool for pharmacokinetic studies.
    Rodrigues M; Alves G; Ferreira A; Queiroz J; Falcão A
    J Chromatogr Sci; 2013 Apr; 51(4):361-70. PubMed ID: 22977121
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simultaneous determination of amiodarone and desethylamiodarone in human plasma by high performance liquid chromatography.
    Mamolo MG; Vio L; Furlan G
    Farmaco; 1992; 47(7-8):1067-80. PubMed ID: 1445614
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simultaneous determination of amiodarone and its major metabolite desethylamiodarone in plasma, urine and tissues by high-performance liquid chromatography.
    Plomp TA; Engels M; Robles de Medina EO; Maes RA
    J Chromatogr; 1983 Apr; 273(2):379-92. PubMed ID: 6863450
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Determination of plasma concentration of amiodarone and desethylamiodarone with high pressure liquid chromatography. Preliminary experience].
    Saavedra I; Ortiz M; Gaete L; Asenjo R; Biagini L
    Rev Med Chil; 1992 Jun; 120(6):661-5. PubMed ID: 1341797
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Preparation and determination of desethylamiodarone in dog lung by HPLC-MS.
    Hong LX; Ying YC; Lei Z; Chen GR
    Pharmazie; 2011 Nov; 66(11):822-5. PubMed ID: 22204125
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High performance liquid chromatographic method for routine monitoring of amiodarone and desethylamiodarone plasma levels.
    Rochas MA; Caillard C; Coulais Y; Sqalli A; Houin G
    Ann Biol Clin (Paris); 1989; 47(3):135-7. PubMed ID: 2712399
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of the class III antiarrhythmic drugs dronedarone and amiodarone, and their principal metabolites in plasma and myocardium by high-performance liquid chromatography and UV-detection.
    Bolderman RW; Hermans JJ; Maessen JG
    J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Jun; 877(18-19):1727-31. PubMed ID: 19427276
    [TBL] [Abstract][Full Text] [Related]  

  • 20. First liquid chromatographic method for the simultaneous determination of amiodarone and desethylamiodarone in human plasma using microextraction by packed sorbent (MEPS) as sample preparation procedure.
    Rodrigues M; Alves G; Rocha M; Queiroz J; Falcão A
    J Chromatogr B Analyt Technol Biomed Life Sci; 2013 Jan; 913-914():90-7. PubMed ID: 23286980
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.