These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 8455492)

  • 1. Photon beam characteristics on the MM50 racetrack microtron and a new approach for beam quality determination.
    Karlsson M; Nyström H; Svensson H
    Med Phys; 1993; 20(1):143-9. PubMed ID: 8455492
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Daily dosimetric quality control of the MM50 Racetrack Microtron using an electronic portal imaging device.
    Dirkx ML; Kroonwijk M; de Boer JC; Heijmen BJ
    Radiother Oncol; 1995 Oct; 37(1):55-60. PubMed ID: 8539457
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electron beam characteristics of the 50-MeV racetrack microtron.
    Karlsson M; Nyström H; Svensson H
    Med Phys; 1992; 19(2):307-15. PubMed ID: 1584123
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Analysis of the photon beam treatment planning data for a scanning beam machine.
    Lovelock DM; Chui CS; Kutcher GJ; Mohan R
    Med Phys; 1994 Dec; 21(12):1969-77. PubMed ID: 7700205
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dosimetric properties of a scanned beam microtron at low monitor unit settings: importance for conformal therapy.
    Humm JL; Larsson A; Lief EP
    Med Phys; 1996 Mar; 23(3):329-35. PubMed ID: 8815374
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Depth dose characteristics of electron beams released from a scanning type Racetrack Microtron treatment machine].
    Sato T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2002 Jan; 58(1):115-23. PubMed ID: 12527882
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Testing of the stability of intensity modulated beams generated with dynamic multileaf collimation, applied to the MM50 racetrack microtron.
    Dirkx ML; Heijmen BJ
    Med Phys; 2000 Dec; 27(12):2701-7. PubMed ID: 11190953
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characteristics of scattered electron beams shaped with a multileaf collimator.
    Moran JM; Martel MK; Bruinvis IA; Fraass BA
    Med Phys; 1997 Sep; 24(9):1491-8. PubMed ID: 9304578
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design of a fast multileaf collimator for radiobiological optimized IMRT with scanned beams of photons, electrons, and light ions.
    Svensson R; Larsson S; Gudowska I; Holmberg R; Brahme A
    Med Phys; 2007 Mar; 34(3):877-88. PubMed ID: 17441233
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Beam characteristics and clinical possibilities of a new compact treatment unit design combining narrow pencil beam scanning and segmental multileaf collimation.
    Svensson R; Lind B; Brahme A
    Med Phys; 1998 Dec; 25(12):2358-69. PubMed ID: 9874828
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mixing intensity modulated electron and photon beams: combining a steep dose fall-off at depth with sharp and depth-independent penumbras and flat beam profiles.
    Korevaar EW; Heijmen BJ; Woudstra E; Huizenga H; Brahme A
    Phys Med Biol; 1999 Sep; 44(9):2171-81. PubMed ID: 10495112
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Depth dose characteristics of photon beams released from a scanning-type racetrack microtron].
    Sato T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2002 Jun; 58(6):809-16. PubMed ID: 12518102
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Determination of head scatter factors released from a scanning-type therapeutic accelerator].
    Sato T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2003 Jul; 59(7):848-56. PubMed ID: 12937406
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Matching of electron and photon beams with a multi-leaf collimator.
    Karlsson M; Zackrisson B
    Radiother Oncol; 1993 Dec; 29(3):317-26. PubMed ID: 8127982
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Shaping of photon beams from electron linear accelerators in radiation therapy.
    Izewska J
    Med Phys; 1993; 20(1):171-7. PubMed ID: 8455496
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dosimetric considerations for a multileaf collimator system.
    Palta JR; Yeung DK; Frouhar V
    Med Phys; 1996 Jul; 23(7):1219-24. PubMed ID: 8839416
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characteristics of electron beams from a medical microtron.
    George RE; Frost SV; Hartson-Eaton M
    Med Phys; 1986; 13(4):533-8. PubMed ID: 3090411
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Monte Carlo study on internal wedges using BEAM.
    van der Zee W; Welleweerd J
    Med Phys; 2002 May; 29(5):876-85. PubMed ID: 12033584
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy.
    LoSasso T; Chui CS; Ling CC
    Med Phys; 1998 Oct; 25(10):1919-27. PubMed ID: 9800699
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electron dose profile shaping by modulation of a scanning elementary beam.
    Lief EP; Larsson A; Humm JL
    Med Phys; 1996 Jan; 23(1):33-44. PubMed ID: 8700031
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.