439 related articles for article (PubMed ID: 8455493)
1. Experimental and theoretical x-ray imaging performance comparison of iodine and lanthanide contrast agents.
Cardinal HN; Holdsworth DW; Drangova M; Hobbs BB; Fenster A
Med Phys; 1993; 20(1):15-31. PubMed ID: 8455493
[TBL] [Abstract][Full Text] [Related]
2. X-ray image intensifier performance and patient doses for combinations of supplemental beam filters and vascular contrast agents.
McParland BJ; Boyd MM
Phys Med Biol; 2001 Jan; 46(1):227-44. PubMed ID: 11197674
[TBL] [Abstract][Full Text] [Related]
3. A comparison of beam-hardening artifacts in x-ray computerized tomography with gadolinium and iodine contrast agents.
Ruth C; Joseph PM
Med Phys; 1995 Dec; 22(12):1977-82. PubMed ID: 8746702
[TBL] [Abstract][Full Text] [Related]
4. Contrast-to-noise ratios of different elements in digital mammography: evaluation of their potential as new contrast agents.
Diekmann F; Sommer A; Lawaczeck R; Diekmann S; Pietsch H; Speck U; Hamm B; Bick U
Invest Radiol; 2007 May; 42(5):319-25. PubMed ID: 17414528
[TBL] [Abstract][Full Text] [Related]
5. Dual-energy cardiac imaging: an image quality and dose comparison for a flat-panel detector and x-ray image intensifier.
Ducote JL; Xu T; Molloi S
Phys Med Biol; 2007 Jan; 52(1):183-96. PubMed ID: 17183135
[TBL] [Abstract][Full Text] [Related]
6. Filter material selection for region of interest radiologic imaging.
Massoumzadeh P; Rudin S; Bednarek DR
Med Phys; 1998 Feb; 25(2):161-71. PubMed ID: 9507475
[TBL] [Abstract][Full Text] [Related]
7. Comparison of entrance exposure and signal-to-noise ratio between an SBDX prototype and a wide-beam cardiac angiographic system.
Speidel MA; Wilfley BP; Star-Lack JM; Heanue JA; Betts TD; Van Lysel MS
Med Phys; 2006 Aug; 33(8):2728-43. PubMed ID: 16964848
[TBL] [Abstract][Full Text] [Related]
8. Relative speeds of Kodak computed radiography phosphors and screen-film systems.
Huda W; Rill LN; Bruner AP
Med Phys; 1997 Oct; 24(10):1621-8. PubMed ID: 9350716
[TBL] [Abstract][Full Text] [Related]
9. Effect of radiographic techniques (kVp and mAs) on image quality and patient doses in digital subtraction angiography.
Gkanatsios NA; Huda W; Peters KR
Med Phys; 2002 Aug; 29(8):1643-50. PubMed ID: 12201409
[TBL] [Abstract][Full Text] [Related]
10. A comparison of mono- and poly-energetic x-ray beam performance for radiographic and fluoroscopic imaging.
Boone JM; Seibert JA
Med Phys; 1994 Dec; 21(12):1853-63. PubMed ID: 7700192
[TBL] [Abstract][Full Text] [Related]
11. Optimization of contrast-enhanced breast imaging: Analysis using a cascaded linear system model.
Hu YH; Scaduto DA; Zhao W
Med Phys; 2017 Jan; 44(1):43-56. PubMed ID: 28044312
[TBL] [Abstract][Full Text] [Related]
12. Effects of x-ray spectra on the DQE of a computed radiography system.
Fetterly KA; Hangiandreou NJ
Med Phys; 2001 Feb; 28(2):241-9. PubMed ID: 11243349
[TBL] [Abstract][Full Text] [Related]
13. Image quality of a digital chest radiography system based on a selenium detector.
Neitzel U; Maack I; Günther-Kohfahl S
Med Phys; 1994 Apr; 21(4):509-16. PubMed ID: 8058016
[TBL] [Abstract][Full Text] [Related]
14. Analysis of the detective quantum efficiency of a developmental detector for digital mammography.
Williams MB; Simoni PU; Smilowitz L; Stanton M; Phillips W; Stewart A
Med Phys; 1999 Nov; 26(11):2273-85. PubMed ID: 10587208
[TBL] [Abstract][Full Text] [Related]
15. Dose optimization in pediatric cardiac x-ray imaging.
Gislason AJ; Davies AG; Cowen AR
Med Phys; 2010 Oct; 37(10):5258-69. PubMed ID: 21089760
[TBL] [Abstract][Full Text] [Related]
16. Comparison of beam-hardening and K-edge filters for imaging barium and iodine during fluoroscopy.
Gagne RM; Quinn PW; Jennings RJ
Med Phys; 1994 Jan; 21(1):107-21. PubMed ID: 8164575
[TBL] [Abstract][Full Text] [Related]
17. Analysis of the kinestatic charge detection system as a high detective quantum efficiency electronic portal imaging device.
Samant SS; Gopal A
Med Phys; 2006 Sep; 33(9):3557-67. PubMed ID: 17022252
[TBL] [Abstract][Full Text] [Related]
18. Dose optimization in cardiac x-ray imaging.
Gislason-Lee AJ; McMillan C; Cowen AR; Davies AG
Med Phys; 2013 Sep; 40(9):091911. PubMed ID: 24007162
[TBL] [Abstract][Full Text] [Related]
19. An examination of automatic exposure control regimes for two digital radiography systems.
Marshall NW
Phys Med Biol; 2009 Aug; 54(15):4645-70. PubMed ID: 19590115
[TBL] [Abstract][Full Text] [Related]
20. Efficacy of fixed filtration for rapid kVp-switching dual energy x-ray systems.
Yao Y; Wang AS; Pelc NJ
Med Phys; 2014 Mar; 41(3):031914. PubMed ID: 24593732
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]