245 related articles for article (PubMed ID: 8456766)
21. Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery.
Pagel PS; Dye L; Hill GED; Vega JL; Tawil JN; De Vry DJ; Chandrashekarappa K; Iqbal Z; Boettcher BT; Freed JK
J Vis Exp; 2018 Nov; (141):. PubMed ID: 30582607
[TBL] [Abstract][Full Text] [Related]
22. Influence of sampling site and flow area on cardiac output measurements by Doppler echocardiography.
Dittmann H; Voelker W; Karsch KR; Seipel L
J Am Coll Cardiol; 1987 Oct; 10(4):818-23. PubMed ID: 3655148
[TBL] [Abstract][Full Text] [Related]
23. Noninvasive maternal stroke volume and cardiac output determinations by pulsed Doppler echocardiography.
Lee W; Rokey R; Cotton DB
Am J Obstet Gynecol; 1988 Mar; 158(3 Pt 1):505-10. PubMed ID: 3348311
[TBL] [Abstract][Full Text] [Related]
24. Automated cardiac output measurement by transesophageal color Doppler echocardiography.
Akamatsu S; Oda A; Terazawa E; Yamamoto T; Ohata H; Michino T; Dohi S
Anesth Analg; 2004 May; 98(5):1232-8, table of contents. PubMed ID: 15105193
[TBL] [Abstract][Full Text] [Related]
25. Transesophageal echocardiographic measurements of cardiac output in cardiac surgical patients.
Izzat MB; Regragui IA; Wilde P; Angelini GD; Bryan AJ
Ann Thorac Surg; 1994 Nov; 58(5):1486-9. PubMed ID: 7979680
[TBL] [Abstract][Full Text] [Related]
26. Measurement of cardiac output in standing horses by Doppler echocardiography and thermodilution.
Blissitt KJ; Young LE; Jones RS; Darke PG; Utting J
Equine Vet J; 1997 Jan; 29(1):18-25. PubMed ID: 9031859
[TBL] [Abstract][Full Text] [Related]
27. Measurement of cardiac output by transoesophageal echocardiography: a comparison of two Doppler methods with thermodilution.
Royse CF; Royse AG; Blake DW; Grigg LE
Anaesth Intensive Care; 1999 Dec; 27(6):586-90. PubMed ID: 10631411
[TBL] [Abstract][Full Text] [Related]
28. Intraoperative estimation of cardiac output by transesophageal pulsed Doppler echocardiography.
Muhiudeen IA; Kuecherer HF; Lee E; Cahalan MK; Schiller NB
Anesthesiology; 1991 Jan; 74(1):9-14. PubMed ID: 1986664
[TBL] [Abstract][Full Text] [Related]
29. Automatic cardiac output measurement (ACOM): clinical applications of a new noninvasive tool.
Trindade PT; Brown P; Puryear JV; Popylisen S; Schnittger I
Int J Card Imaging; 1998 Jun; 14(3):147-54. PubMed ID: 9813750
[TBL] [Abstract][Full Text] [Related]
30. Effects of velocity distribution, diameter measurement and velocity tracing on the accuracy of cardiac output measurement by pulsed Doppler echocardiography in the aortic annulus of pigs.
Zhou YQ; Faerestrand S; Birkeland S; Matre K; Husby P; Koller ME
Ultrasound Med Biol; 1997; 23(2):177-85. PubMed ID: 9140176
[TBL] [Abstract][Full Text] [Related]
31. Accuracy of cardiac output measurements with pulse contour analysis (PulseCO) and Doppler echocardiography during off-pump coronary artery bypass grafting.
Missant C; Rex S; Wouters PF
Eur J Anaesthesiol; 2008 Mar; 25(3):243-8. PubMed ID: 17996125
[TBL] [Abstract][Full Text] [Related]
32. Comparison of Cardiac Output of Both 2-Dimensional and 3-Dimensional Transesophageal Echocardiography With Transpulmonary Thermodilution During Cardiac Surgery.
Canty DJ; Kim M; Guha R; Pham T; Royse AG; Errey-Clarke S; Smith JA; Royse CF
J Cardiothorac Vasc Anesth; 2020 Jan; 34(1):77-86. PubMed ID: 31375406
[TBL] [Abstract][Full Text] [Related]
33. Multiplane transesophageal echocardiographic doppler imaging accurately determines cardiac output measurements in critically ill patients.
Feinberg MS; Hopkins WE; Davila-Roman VG; Barzilai B
Chest; 1995 Mar; 107(3):769-73. PubMed ID: 7874951
[TBL] [Abstract][Full Text] [Related]
34. Noninvasive versus invasive assessment of cardiac output after cardiac surgery: clinical validation.
Spahn DR; Schmid ER; Tornic M; Jenni R; von Segesser L; Turina M; Baetscher A
J Cardiothorac Anesth; 1990 Feb; 4(1):46-59. PubMed ID: 2131856
[TBL] [Abstract][Full Text] [Related]
35. [Transesophageal Doppler echocardiographic measurement of cardiac output using mitral anulus method].
Shimamoto H; Kito H; Kawazoe K; Fujita T
Kokyu To Junkan; 1991 Jul; 39(7):665-8. PubMed ID: 1896657
[TBL] [Abstract][Full Text] [Related]
36. Continuous cardiac output measurement: arterial pressure analysis versus thermodilution technique during cardiac surgery with cardiopulmonary bypass.
Lorsomradee S; Lorsomradee SR; Cromheecke S; De Hert SG
Anaesthesia; 2007 Oct; 62(10):979-83. PubMed ID: 17845647
[TBL] [Abstract][Full Text] [Related]
37. [Intraoperative determination of heart time volume with transesophageal pulsed Doppler echocardiography].
Roewer N; Bednarz F; Kochs E; Schulte am Esch J
Anaesthesist; 1988 Jun; 37(6):345-55. PubMed ID: 3407898
[TBL] [Abstract][Full Text] [Related]
38. USCOM (Ultrasonic Cardiac Output Monitors) lacks agreement with thermodilution cardiac output and transoesophageal echocardiography valve measurements.
Van den Oever HL; Murphy EJ; Christie-Taylor GA
Anaesth Intensive Care; 2007 Dec; 35(6):903-10. PubMed ID: 18084981
[TBL] [Abstract][Full Text] [Related]
39. Comparison of thermodilution bolus cardiac output and Doppler cardiac output in the early post-cardiopulmonary bypass period.
Zhao X; Mashikian JS; Panzica P; Lerner A; Park KW; Comunale ME
J Cardiothorac Vasc Anesth; 2003 Apr; 17(2):193-8. PubMed ID: 12698401
[TBL] [Abstract][Full Text] [Related]
40. Continuous noninvasive monitoring of cardiac output with esophageal Doppler ultrasound during cardiac surgery.
Mark JB; Steinbrook RA; Gugino LD; Maddi R; Hartwell B; Shemin R; DiSesa V; Rida WN
Anesth Analg; 1986 Oct; 65(10):1013-20. PubMed ID: 3530048
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]