BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 8458664)

  • 1. Effects of grip and push forces on the acute response of the hand-arm system under vibrating conditions.
    Hartung E; Dupuis H; Scheffer M
    Int Arch Occup Environ Health; 1993; 64(6):463-7. PubMed ID: 8458664
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Consideration of grip and push forces for the assessment of vibration exposure.
    Riedel S
    Cent Eur J Public Health; 1995; 3 Suppl():139-41. PubMed ID: 9150996
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The relationships between hand coupling force and vibration biodynamic responses of the hand-arm system.
    Pan D; Xu XS; Welcome DE; McDowell TW; Warren C; Wu J; Dong RG
    Ergonomics; 2018 Jun; 61(6):818-830. PubMed ID: 29086628
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Acute effects of vibration from a chipping hammer and a grinder on the hand-arm system.
    Kihlberg S; Attebrant M; Gemne G; Kjellberg A
    Occup Environ Med; 1995 Nov; 52(11):731-7. PubMed ID: 8535492
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Acute effects of shock-type vibration transmitted to the hand-arm system.
    Schäfer N; Dupuis H; Hartung E
    Int Arch Occup Environ Health; 1984; 55(1):49-59. PubMed ID: 6526500
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mechanical impedance and absorbed power of hand-arm under x(h)-axis vibration and role of hand forces and posture.
    Aldien Y; Marcotte P; Rakheja S; Boileau PE
    Ind Health; 2005 Jul; 43(3):495-508. PubMed ID: 16100926
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measurement and evaluation of coupling forces when using hand-held power tools.
    Kaulbars U
    Cent Eur J Public Health; 1996 Feb; 4(1):57-8. PubMed ID: 8996673
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Different acute effects of single-axis and multi-axis hand-arm vibration.
    Stelling J; Dupuis H
    Int Arch Occup Environ Health; 1996; 68(4):236-42. PubMed ID: 8738353
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Bone and joint pathology in workers using hand-held vibrating tools. An overview.
    Gemne G; Saraste H
    Scand J Work Environ Health; 1987 Aug; 13(4):290-300. PubMed ID: 3324310
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The influence of biodynamic factors on the mechanical impedance of the hand and arm.
    Burström L
    Int Arch Occup Environ Health; 1997; 69(6):437-46. PubMed ID: 9215931
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Temporary threshold shift of vibratory sensation induced by a vibrating handle and its gripping force.
    Nishiyama K; Taoda K; Yamashita H; Watanabe S
    Int Arch Occup Environ Health; 1996; 69(1):45-52. PubMed ID: 9017434
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Estimation of biodynamic forces distributed on the fingers and the palm exposed to vibration.
    Dong RG; Welcome DE; Wu JZ
    Ind Health; 2005 Jul; 43(3):485-94. PubMed ID: 16100925
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The influence of individual factors on the absorption of vibration energy in the hand and arm.
    Burström L
    Cent Eur J Public Health; 1996 Feb; 4(1):50-2. PubMed ID: 8996671
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reduction of the vibration of the hand-arm system by optimization of rotary hammer drills.
    Weinert K; Gillmeister F
    Cent Eur J Public Health; 1996 Feb; 4(1):36-9. PubMed ID: 8996667
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biodynamic response at the palm of the human hand subjected to a random vibration.
    Dong RG; McDowell TW; Welcome DE
    Ind Health; 2005 Jan; 43(1):241-55. PubMed ID: 15732329
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The influence of human interaction on the vibration of hand-held human-machine systems - The effect of body posture, feed force, and gripping forces on the vibration of hammer drills.
    Lindenmann A; Uhl M; Gwosch T; Matthiesen S
    Appl Ergon; 2021 Sep; 95():103430. PubMed ID: 33957304
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Vibration energy absorption (VEA) in human fingers-hand-arm system.
    Dong RG; Schopper AW; McDowell TW; Welcome DE; Wu JZ; Smutz WP; Warren C; Rakheja S
    Med Eng Phys; 2004 Jul; 26(6):483-92. PubMed ID: 15234684
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Single number index of vibratory and force load during hand-arm vibration].
    Denisov EI
    Med Tr Prom Ekol; 1999; (6):34-6. PubMed ID: 10420716
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hand vibration: non-contact measurement of local transmissibility.
    Scalise L; Rossetti F; Paone N
    Int Arch Occup Environ Health; 2007 Oct; 81(1):31-40. PubMed ID: 17410375
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hand-transmitted vibration and biodynamic response of the human hand-arm: a critical review.
    Dong RG; Rakheja S; Schopper AW; Han B; Smutz WP
    Crit Rev Biomed Eng; 2001; 29(4):393-439. PubMed ID: 11822480
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.