These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 8464378)

  • 1. Development and characterization of an ergometer to study the bioenergetics of the human quadriceps muscle by 31P NMR spectroscopy inside a standard MR scanner.
    González de Suso JM; Bernús G; Alonso J; Alay A; Capdevila A; Gili J; Prat JA; Arús C
    Magn Reson Med; 1993 Apr; 29(4):575-81. PubMed ID: 8464378
    [TBL] [Abstract][Full Text] [Related]  

  • 2. 31P-MRS and simultaneous quantification of dynamic human quadriceps exercise in a whole body MR scanner.
    Rodenburg JB; de Boer RW; Jeneson JA; van Echteld CJ; Bär PR
    J Appl Physiol (1985); 1994 Aug; 77(2):1021-9. PubMed ID: 8002487
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Muscle activity localization with 31P spectroscopy and calculated T2-weighted 1H images.
    Weidman ER; Charles HC; Negro-Vilar R; Sullivan MJ; MacFall JR
    Invest Radiol; 1991 Apr; 26(4):309-16. PubMed ID: 2032818
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simultaneous 31P NMR spectroscopy and EMG in exercising and recovering human skeletal muscle: technical aspects.
    Vestergaard-Poulsen P; Thomsen C; Sinkjaer T; Henriksen O
    Magn Reson Med; 1994 Feb; 31(2):93-102. PubMed ID: 8133762
    [TBL] [Abstract][Full Text] [Related]  

  • 5. MR-compatible pedal ergometer for reproducible exercising of the human calf muscle.
    Tschiesche K; Rothamel M; Rzanny R; Gussew A; Hiepe P; Reichenbach JR
    Med Eng Phys; 2014 Jul; 36(7):933-7. PubMed ID: 24703504
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dynamic 31P MR spectroscopy of plantar flexion: influence of ergometer design, magnetic field strength (3 and 7 T), and RF-coil design.
    Šedivý P; Kipfelsberger MC; Dezortová M; Krššák M; Drobný M; Chmelík M; Rydlo J; Trattnig S; Hájek M; Valkovič L
    Med Phys; 2015 Apr; 42(4):1678-89. PubMed ID: 25832057
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A simple ergometer for 31P NMR spectroscopy during dynamic forearm exercise in a whole body magnetic resonance imaging system.
    Nishijima H; Nishida M; Anzai T; Yonezawa K; Fukuda H; Sato I; Yasuda H
    Jpn Heart J; 1992 Mar; 33(2):185-92. PubMed ID: 1593748
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A simple calf muscle ergometer for use in a standard whole-body MR scanner.
    Quistorff B; Nielsen S; Thomsen C; Jensen KE; Henriksen O
    Magn Reson Med; 1990 Mar; 13(3):444-9. PubMed ID: 2325544
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An MR-compatible bicycle ergometer for in-magnet whole-body human exercise testing.
    Jeneson JA; Schmitz JP; Hilbers PA; Nicolay K
    Magn Reson Med; 2010 Jan; 63(1):257-61. PubMed ID: 19918886
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Combined spiroergometry and
    Moll K; Gussew A; Hein C; Stutzig N; Reichenbach JR
    NMR Biomed; 2017 Jul; 30(7):. PubMed ID: 28340292
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characteristics of a MR-compatible ankle exercise ergometer for a 3.0 T head-only MR scanner.
    Raymer GH; Allman BL; Rice CL; Marsh GD; Thompson RT
    Med Eng Phys; 2006 Jun; 28(5):489-94. PubMed ID: 16162418
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A low-cost Mr compatible ergometer to assess post-exercise phosphocreatine recovery kinetics.
    Naimon ND; Walczyk J; Babb JS; Khegai O; Che X; Alon L; Regatte RR; Brown R; Parasoglou P
    MAGMA; 2017 Jun; 30(3):281-289. PubMed ID: 28054143
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simultaneous electromyography and 31P nuclear magnetic resonance spectroscopy--with application to muscle fatigue.
    Vestergaard-Poulsen P; Thomsen C; Sinkjaer T; Stubgaard M; Rosenfalck A; Henriksen O
    Electroencephalogr Clin Neurophysiol; 1992 Dec; 85(6):402-11. PubMed ID: 1282459
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Two-pedal ergometer for in vivo MRS studies of human calf muscles.
    Francescato MP; Cettolo V
    Magn Reson Med; 2001 Nov; 46(5):1000-5. PubMed ID: 11675653
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Dynamic knee-extensor and cycle exercise: functional MRI of muscular activity.
    Richardson RS; Frank LR; Haseler LJ
    Int J Sports Med; 1998 Apr; 19(3):182-7. PubMed ID: 9630023
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of training on the calf muscle energy metabolism. A 31P-NMR study on four elite downhill skiers challenged with a standardized exercise protocol.
    Laurent D; Bernús G; Alonso J; Lebas JF; Arús C; González de Suso JM; Rossi A
    Int J Sports Med; 1992 May; 13(4):313-8. PubMed ID: 1521945
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Magnetic resonance spectroscopy and imaging of muscle--a physiological approach.
    Edwards RH; Gibson H; Roberts N; Clague JE; Martin PA
    Int J Sports Med; 1992 Oct; 13 Suppl 1():S143-6. PubMed ID: 1483755
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Changes in magnetic resonance transverse relaxation times of two muscles following standardized exercise.
    Price TB; McCauley TR; Duleba AJ; Wilkens KL; Gore JC
    Med Sci Sports Exerc; 1995 Oct; 27(10):1421-9. PubMed ID: 8531614
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 31P-NMR spectroscopy and the metabolic properties of different muscle fibers.
    Achten E; Van Cauteren M; Willem R; Luypaert R; Malaisse WJ; Van Bosch G; Delanghe G; De Meirleir K; Osteaux M
    J Appl Physiol (1985); 1990 Feb; 68(2):644-9. PubMed ID: 2318775
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Direct relationship between proton T2 and exercise intensity in skeletal muscle MR images.
    Fisher MJ; Meyer RA; Adams GR; Foley JM; Potchen EJ
    Invest Radiol; 1990 May; 25(5):480-5. PubMed ID: 2345077
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.