BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 8464663)

  • 1. Oscillometric blood pressures in the arm, thigh, and calf in healthy children and those with aortic coarctation.
    Park MK; Lee DH; Johnson GA
    Pediatrics; 1993 Apr; 91(4):761-5. PubMed ID: 8464663
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Normative arm and calf blood pressure values in the newborn.
    Park MK; Lee DH
    Pediatrics; 1989 Feb; 83(2):240-3. PubMed ID: 2913554
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Blood pressure difference between upper arm and thigh, and aortic stiffness in healthy subjects and in patients after coarcectomy].
    Motz R; Waltner-Romen M; Geiger R; Wessel A
    Klin Padiatr; 2001; 213(5):290-4. PubMed ID: 11582529
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of upper arm and calf oscillometric blood pressure measurement in preterm infants.
    Kunk R; McCain GC
    J Perinatol; 1996; 16(2 Pt 1):89-92. PubMed ID: 8732553
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Calf blood pressure: clinical implications and correlations with arm blood pressure in infants and young children.
    Crapanzano MS; Strong WB; Newman IR; Hixon RL; Casal D; Linder CW
    Pediatrics; 1996 Feb; 97(2):220-4. PubMed ID: 8584381
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Coarctation of the aorta: Noninvasive physiological assessment in infants and children before and after operation.
    Waldman JD; Goodman AH; Tumeo AR; Lamberti JJ; Turner SW
    J Thorac Cardiovasc Surg; 1980 Aug; 80(2):187-97. PubMed ID: 7401669
    [No Abstract]   [Full Text] [Related]  

  • 7. [Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm].
    Saul F; Aristidou Y; Klaus D; Wiemeyer A; Lösse B
    Z Kardiol; 1995 Sep; 84(9):675-85. PubMed ID: 8525669
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of partial cardiopulmonary bypass for coarctation repair through a left thoracotomy in children without collaterals.
    Backer CL; Stewart RD; Kelle AM; Mavroudis C
    Ann Thorac Surg; 2006 Sep; 82(3):964-72. PubMed ID: 16928517
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validation of three oscillometric blood pressure devices against auscultatory mercury sphygmomanometer in children.
    Wong SN; Tz Sung RY; Leung LC
    Blood Press Monit; 2006 Oct; 11(5):281-91. PubMed ID: 16932037
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Noninvasive monitoring of blood pressure in the critically ill: reliability according to the cuff site (arm, thigh, or ankle).
    Lakhal K; Macq C; Ehrmann S; Boulain T; Capdevila X
    Crit Care Med; 2012 Apr; 40(4):1207-13. PubMed ID: 22425818
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Pulsed Doppler in children operated on for aortic coarctation: reliability in the evaluation of minor residual lesions].
    Marasini M; Pongiglione G; Ribaldone D; Bertolini A; Garello-Cantoni L
    G Ital Cardiol; 1986 Sep; 16(9):734-40. PubMed ID: 2948861
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Suspicion of aortic coarctation in an outpatient clinic: how should blood pressure measurements be performed?
    Rahiala E; Tikanoja T
    Clin Physiol; 2001 Jan; 21(1):100-4. PubMed ID: 11168303
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of three measures of the ankle-brachial blood pressure index in a general population.
    Pan CR; Staessen JA; Li Y; Wang JG
    Hypertens Res; 2007 Jun; 30(6):555-61. PubMed ID: 17664860
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of blood pressure measurement by the Dinamap monitor in infants and children.
    Park MK; Menard SM
    Pediatrics; 1987 Jun; 79(6):907-14. PubMed ID: 3588145
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Comparison between brachial blood pressures obtained by aneroid sphygmomanometer and central aortic pressures: factors affecting the measurements].
    Kayrak M; Ulgen MS; Yazici M; Demir K; Doğan Y; Koç F; Zengin K; Ari H
    Turk Kardiyol Dern Ars; 2008 Jun; 36(4):239-46. PubMed ID: 18765967
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Variability of four limb blood pressure in normal neonates.
    Crossland DS; Furness JC; Abu-Harb M; Sadagopan SN; Wren C
    Arch Dis Child Fetal Neonatal Ed; 2004 Jul; 89(4):F325-7. PubMed ID: 15210667
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Random zero sphygmomanometer versus automatic oscillometric blood pressure monitor; is either the instrument of choice?
    Goonasekera CD; Dillon MJ
    J Hum Hypertens; 1995 Nov; 9(11):885-9. PubMed ID: 8583467
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Development of exercise-induced arm-leg blood pressure gradient and abnormal arterial compliance in patients with repaired coarctation of the aorta.
    Markham LW; Knecht SK; Daniels SR; Mays WA; Khoury PR; Knilans TK
    Am J Cardiol; 2004 Nov; 94(9):1200-2. PubMed ID: 15518624
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of Dinamap PRO-100 and mercury sphygmomanometer blood pressure measurements in a population-based study.
    Ni H; Wu C; Prineas R; Shea S; Liu K; Kronmal R; Bild D
    Am J Hypertens; 2006 Apr; 19(4):353-60. PubMed ID: 16580569
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Continuous-wave Doppler velocimeters and blood pressure difference in aortic coarctation. A simultaneous comparative study of 52 children].
    Barth H; Hassberg D; Schmaltz AA; Steil E; Apitz J
    Herz; 1987 Jun; 12(3):217-25. PubMed ID: 2957295
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.