  • 1. Reliability of measuring forward head posture in a clinical setting.
    Garrett TR; Youdas JW; Madson TJ
    J Orthop Sports Phys Ther; 1993 Mar; 17(3):155-60. PubMed ID: 8472080
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reliability and validity of head posture assessment by observation and a four-category scale.
    Silva AG; Punt TD; Johnson MI
    Man Ther; 2010 Oct; 15(5):490-5. PubMed ID: 20627799
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intratester and intertester reliability of the Cybex electronic digital inclinometer (EDI-320) for measurement of active neck flexion and extension in healthy subjects.
    Tousignant M; Boucher N; Bourbonnais J; Gravelle T; Quesnel M; Brosseau L
    Man Ther; 2001 Nov; 6(4):235-41. PubMed ID: 11673934
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intrarater reliability of CROM measurement of cervical spine active range of motion in persons with and without neck pain.
    Fletcher JP; Bandy WD
    J Orthop Sports Phys Ther; 2008 Oct; 38(10):640-5. PubMed ID: 18827326
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Standardized initial head position in cervical range-of-motion assessment: reliability and error analysis.
    Solinger AB; Chen J; Lantz CA
    J Manipulative Physiol Ther; 2000 Jan; 23(1):20-6. PubMed ID: 10658872
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validity and between-day reliability of the cervical range of motion (CROM) device.
    Audette I; Dumas JP; Côté JN; De Serres SJ
    J Orthop Sports Phys Ther; 2010 May; 40(5):318-23. PubMed ID: 20436238
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Measurement of cervical range of motion (CROM) by electronic CROM goniometer: a test of reliability and validity.
    Law EY; Chiu TT
    J Back Musculoskelet Rehabil; 2013; 26(2):141-8. PubMed ID: 23640315
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intratester and intertester reliability of the cervical range of motion device.
    Capuano-Pucci D; Rheault W; Aukai J; Bracke M; Day R; Pastrick M
    Arch Phys Med Rehabil; 1991 Apr; 72(5):338-40. PubMed ID: 2009054
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reliability of cervical range of motion using the OSI CA 6000 spine motion analyser on asymptomatic and symptomatic subjects.
    Petersen CM; Johnson RD; Schuit D
    Man Ther; 2000 May; 5(2):82-8. PubMed ID: 10903583
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reliability and validity of a Coda Motion 3-D Analysis system for measuring cervical range of motion in healthy subjects.
    Song H; Zhai X; Gao Z; Lu T; Tian Q; Li H; He X
    J Electromyogr Kinesiol; 2018 Feb; 38():56-66. PubMed ID: 29169054
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reproducibility and validity of digital inclinometry for measuring cervical range of motion in normal subjects.
    Prushansky T; Deryi O; Jabarreen B
    Physiother Res Int; 2010 Mar; 15(1):42-8. PubMed ID: 19554615
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validity and reliability of head posture measurement using Microsoft Kinect.
    Oh BL; Kim J; Kim J; Hwang JM; Lee J
    Br J Ophthalmol; 2014 Nov; 98(11):1560-4. PubMed ID: 25271910
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Sitting bodily configuration: a study investigating the intra-tester reliability of positioning subjects into a predetermined sitting posture.
    Korakakis V; Sideris V; Giakas G
    Man Ther; 2014 Jun; 19(3):197-202. PubMed ID: 24480626
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Quantitative measurements of forward head in college-aged students: A conformational study of intra-rater and inter-rater reliability of a novel Posture Measuring Device.
    Gray K; Dalal R; Davis Weaver J; Randolph S
    J Bodyw Mov Ther; 2021 Apr; 26():233-237. PubMed ID: 33992250
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improvement after chiropractic care in cervicocephalic kinesthetic sensibility and subjective pain intensity in patients with nontraumatic chronic neck pain.
    Palmgren PJ; Sandström PJ; Lundqvist FJ; Heikkilä H
    J Manipulative Physiol Ther; 2006 Feb; 29(2):100-6. PubMed ID: 16461168
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reliability of measurements of cervical spine range of motion--comparison of three methods.
    Youdas JW; Carey JR; Garrett TR
    Phys Ther; 1991 Feb; 71(2):98-104; discussion 105-6. PubMed ID: 1989013
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Clinical measurement of craniovertebral angle by electronic head posture instrument: a test of reliability and validity.
    Cheung Lau HM; Wing Chiu TT; Lam TH
    Man Ther; 2009 Aug; 14(4):363-8. PubMed ID: 18694655
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Increased forward head posture and restricted cervical range of motion in patients with carpal tunnel syndrome.
    De-la-Llave-Rincón AI; Fernández-de-las-Peñas C; Palacios-Ceña D; Cleland JA
    J Orthop Sports Phys Ther; 2009 Sep; 39(9):658-64. PubMed ID: 19721213
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement proprieties of the CROM instrument for assessing head posture, neck retraction and protraction.
    Elizagaray-García I; Obispo-Villamayor Á; Prats-Martínez C; Prieto-Hernández G; Carvalho GF
    Musculoskelet Sci Pract; 2024 Jun; 71():102950. PubMed ID: 38574577
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Using the cervical range of motion (CROM) device to assess head repositioning accuracy in individuals with cervical radiculopathy in comparison to neck- healthy individuals.
    Wibault J; Vaillant J; Vuillerme N; Dedering Å; Peolsson A
    Man Ther; 2013 Oct; 18(5):403-9. PubMed ID: 23473752
    [TBL] [Abstract][Full Text] [Related]  