These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

203 related articles for article (PubMed ID: 8480348)

  • 1. Lack of clinical significance of "enzyme-only" red cell alloantibodies.
    Issitt PD; Combs MR; Bredehoeft SJ; Campbell ML; Heimer M; Joyner L; Lorentsen L; Remley C; Bullock S; Bumgarner J
    Transfusion; 1993 Apr; 33(4):284-93. PubMed ID: 8480348
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Evaluation of the polyethyleneglycol antiglobulin test in the detection and identification of erythrocyte antibodies].
    Jiménez Marco MT; Hernández Maraver D; Rodríguez de la Rua A; de la Cámara Mendizábal C; Canales Albendea M; Jiménez Yuste V; Hernández Navarro F
    Sangre (Barc); 1998 Feb; 43(1):21-4. PubMed ID: 9577178
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Indirect antiglobulin test-crossmatch using low-ionic-strength saline-albumin enhancement medium and reduced incubation time: effectiveness in the detection of most clinically significant antibodies and impact on blood utilization.
    Dinardo CL; Bonifácio SL; Mendrone A
    Immunohematology; 2014; 30(1):1-5. PubMed ID: 25238242
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Value of using polyethylene glycol in the indirect antiglobulin test with erythrocytes].
    Michalewska B; Walewska I; Seyfriedowa H; Kuśnierz-Alejska G
    Acta Haematol Pol; 1991; 22(1):105-12. PubMed ID: 1823951
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The manual polybrene test: a simple and rapid procedure for detection of red cell antibodies.
    Lalezari P; Jiang AF
    Transfusion; 1980; 20(2):206-11. PubMed ID: 6768173
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of a commercial hexadimethrine bromide method and low-ionic-strength solution for antibody detection with special reference to anti-K.
    Letendre PL; Williams MA; Ferguson DJ
    Transfusion; 1987; 27(2):138-41. PubMed ID: 3103267
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of a manual hexadimethrine bromide-antiglobulin test with saline- and albumin-antiglobulin tests for pretransfusion testing.
    Mintz PD; Anderson G
    Transfusion; 1987; 27(2):134-7. PubMed ID: 3824470
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the polyethylene glycol-potentiated indirect antiglobulin test.
    Wenz B; Apuzzo J; Shah DP
    Transfusion; 1990 May; 30(4):318-21. PubMed ID: 2112277
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hemolytic transfusion reaction due to Rh antibodies detectable only by manual polybrene and polyethylene glycol technique.
    Lin CK; Wong KF; Mak KH; Yuen CM; Lee AW
    Am J Clin Pathol; 1995 Dec; 104(6):660-2. PubMed ID: 8526209
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Comparison of several methods for detecting anti-erythrocyte alloantibodies].
    Bencomo AA
    Sangre (Barc); 1990 Aug; 35(4):307-10. PubMed ID: 2125752
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of low ionic diluents for use with the Diamed antiglobulin gel test.
    Grey D; Connolly M; Erber WN
    Transfus Med; 2002 Feb; 12(1):63-9. PubMed ID: 11967139
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Automated reading of red cell antibody identification tests by a solid phase antiglobulin technique.
    Moore HH
    Transfusion; 1984; 24(3):218-21. PubMed ID: 6427989
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of the performance of microtube column systems and solid-phase systems and the tube low-ionic-strength solution additive indirect antiglobulin test in the detection of red cell alloantibodies.
    Weisbach V; Kohnhäuser T; Zimmermann R; Ringwald J; Strasser E; Zingsem J; Eckstein R
    Transfus Med; 2006 Aug; 16(4):276-84. PubMed ID: 16879156
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of the performance of four microtube column agglutination systems in the detection of red cell alloantibodies.
    Weisbach V; Ziener A; Zimmermann R; Glaser A; Zingsem J; Eckstein R
    Transfusion; 1999 Oct; 39(10):1045-50. PubMed ID: 10532596
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Red cell antibodies and low ionic strength: a study with enzyme-linked antiglobulin test.
    Leikola J; Perkins HA
    Transfusion; 1980; 20(2):224-8. PubMed ID: 6768174
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A proposal for compatibility testing incorporating the manual hexadimethrine bromide (Polybrene) test.
    Steane EA; Steane SM; Montgomery SR; Pearson JR
    Transfusion; 1985; 25(6):540-4. PubMed ID: 4071598
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detection of red cell antibodies: comparison of two low ionic strength diluents.
    Skaik YA; Overfield J
    Br J Biomed Sci; 2006; 63(1):18-20. PubMed ID: 16613136
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An antibody that recognizes a determinant common to S and s-bearing sialoglycoproteins.
    Issitt PD; Tregellas WM; Lee C; Wilkinson SL
    Transfusion; 1982; 22(3):174-9. PubMed ID: 6806948
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Immunohematologic study and transfusion approach to patients with public antibodies].
    Solves P; de la Rubia J; Arriaga F; Cervera J; Arnao M; Carpio N; Marty ML
    Sangre (Barc); 1997 Feb; 42(1):25-9. PubMed ID: 9229799
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of six procedures for compatibility testing.
    Greendyke RM; Banzhaf JC; Inglis J
    Transfusion; 1979; 19(6):782-6. PubMed ID: 524436
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.