BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

97 related articles for article (PubMed ID: 8481258)

  • 1. Early results of intravascular oxygenation.
    Kallis P; al-Saady NM; Bennett ED; Treasure T
    Eur J Cardiothorac Surg; 1993; 7(4):206-10. PubMed ID: 8481258
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo gas transfer performance of the intravascular oxygenator in acute respiratory failure.
    Conrad SA; Zwischenberger JB; Eggerstedt JM; Bidani A
    Artif Organs; 1994 Nov; 18(11):840-5. PubMed ID: 7864734
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Use of an intravascular oxygenator/carbon dioxide removal device in an ovine smoke inhalation injury model.
    Cox CS; Zwischenberger JB; Traber LD; Traber DL; Herndon DN
    ASAIO Trans; 1991; 37(3):M411-3. PubMed ID: 1751213
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intravenacaval membrane oxygenation and carbon dioxide removal in severe acute respiratory failure.
    Conrad SA; Eggerstedt JM; Grier LR; Morris VF; Romero MD
    Chest; 1995 Jun; 107(6):1689-97. PubMed ID: 7781369
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intravascular oxygenation for advanced respiratory failure.
    Jurmann MJ; Demertzis S; Schaefers HJ; Wahlers T; Haverich A
    ASAIO J; 1992; 38(2):120-4. PubMed ID: 1421605
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reduction of ventilator settings allowed by intravenous oxygenator (IVOX) in ARDS patients.
    Mira JP; Brunet F; Belghith M; Soubrane O; Termignon JL; Renaud B; Hamy I; Monchi M; Deslande E; Fierobe L
    Intensive Care Med; 1995 Jan; 21(1):11-7. PubMed ID: 7560467
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Permissive hypercapnia and intravascular oxygenator in the treatment of patients with ARDS.
    Brunet F; Mira JP; Cerf C; Belghith M; Soubrane O; Termignon JL; Renaud B; Fierobe L; Hamy I; Monchi M
    Artif Organs; 1994 Nov; 18(11):826-32. PubMed ID: 7864732
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intravascular membrane oxygenation and carbon dioxide removal with IVOX: can improved design and permissive hypercapnia achieve adequate respiratory support during severe respiratory failure?
    Zwischenberger JB; Cardenas VJ; Tao W; Niranjan SC; Clark JW; Bidani A
    Artif Organs; 1994 Nov; 18(11):833-9. PubMed ID: 7864733
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The intravascular oxygenator (IVOX): preliminary results of a new means of performing extrapulmonary gas exchange.
    Gentilello LM; Jurkovich GJ; Gubler KD; Anardi DM; Heiskell R
    J Trauma; 1993 Sep; 35(3):399-404. PubMed ID: 8371298
    [TBL] [Abstract][Full Text] [Related]  

  • 10. IVOX with gradual permissive hypercapnia: a new management technique for respiratory failure.
    Zwischenberger JB; Nguyen TT; Tao W; Bush PE; Cox CS; Traber DL; Herndon DN; Bidani A
    J Surg Res; 1994 Jul; 57(1):99-105. PubMed ID: 8041157
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The peri-operative management of surgical insertion and removal of the intravenous oxygenator device (IVOX). A report of nine cases.
    Murdoch LJ; Boyd OF; Mackay J; Bennett ED; Grounds RM
    Anaesthesia; 1993 Oct; 48(10):845-8. PubMed ID: 8238824
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Major findings from the clinical trials of the intravascular oxygenator.
    Conrad SA; Bagley A; Bagley B; Schaap RN
    Artif Organs; 1994 Nov; 18(11):846-63. PubMed ID: 7864735
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prolonged intracorporeal support of gas exchange with an intravenacaval oxygenator.
    Conrad SA; Eggerstedt JM; Morris VF; Romero MD
    Chest; 1993 Jan; 103(1):158-61. PubMed ID: 8417871
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Present status of IVOX device].
    Terada Y
    Rinsho Kyobu Geka; 1994 Dec; 14(6):461-4. PubMed ID: 9423123
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intravascular membrane oxygenator and carbon dioxide removal devices: a review of performance and improvements.
    Zwischenberger JB; Tao W; Bidani A
    ASAIO J; 1999; 45(1):41-6. PubMed ID: 9952005
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative gas transfer into and out of circulating venous blood by means of an intravenacaval oxygenator.
    Bagley B; Bagley A; Henrie J; Froerer C; Brohamer J; Burkart J; Mortensen JD
    ASAIO Trans; 1991; 37(3):M413-5. PubMed ID: 1751214
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Rate of thrombus accumulation on intravenacaval IVOX devices explanted from human clinical trial patients with acute respiratory failure.
    Imai H; Schaap RN; Mortensen JD
    Artif Organs; 1994 Nov; 18(11):818-21. PubMed ID: 7864730
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intracorporeal CO2 removal and permissive hypercapnia to reduce airway pressure in acute respiratory failure. The theoretical basis for permissive hypercapnia with IVOX.
    Cox CS; Zwischenberger JB; Graves DF; Niranjan SC; Bidani A
    ASAIO J; 1993; 39(2):97-102. PubMed ID: 8324269
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development and current status of a new intracorporeal membrane oxygenator (IVOX).
    Cox CS; Zwischenberger JB; Kurusz M
    Perfusion; 1991; 6(4):291-6. PubMed ID: 10149513
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [The experience of extracorporeal membrane oxygenation for severe acute respiratory failure in adults].
    Sun B; Wang CT; Wu J; Li XY; He HY; Zhang CY; Tong ZH; Zhan QY; Wang C
    Zhonghua Jie He He Hu Xi Za Zhi; 2012 Nov; 35(11):804-8. PubMed ID: 23290033
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.