BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

83 related articles for article (PubMed ID: 8486402)

  • 1. Reduction of the cost of testing for antibody to human immunodeficiency virus, without losing sensitivity, by pooling sera.
    Babu PG; Saraswathi NK; Vaidyanathan H; John TJ
    Indian J Med Res; 1993 Jan; 97():1-3. PubMed ID: 8486402
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pooling of sera for human immunodeficiency virus (HIV) testing: an economical method for use in developing countries.
    Emmanuel JC; Bassett MT; Smith HJ; Jacobs JA
    J Clin Pathol; 1988 May; 41(5):582-5. PubMed ID: 3164325
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reducing the cost of HIV antibody testing.
    Tamashiro H; Maskill W; Emmanuel J; Fauquex A; Sato P; Heymann D
    Lancet; 1993 Jul; 342(8863):87-90. PubMed ID: 8100916
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of efficacy of pooled sera in a human immunodeficiency virus antibody prevalence in population surveys.
    Pătraşcu IV
    Rev Roum Virol; 1990; 41(1):45-51. PubMed ID: 2223657
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Relevance of antibody content and test format in HIV testing of pooled sera.
    Monzon OT; Paladin FJ; Dimaandal E; Balis AM; Samson C; Mitchell S
    AIDS; 1992 Jan; 6(1):43-8. PubMed ID: 1543565
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Site-directed enzyme-linked immunosorbent assay with a synthetic simian immunodeficiency virus SIVmac peptide identifying antibodies against the HIV-2 transmembrane glycoprotein.
    Norrby E; Chiodi F; Whalley A; Parks E; Nauclér A; Costa CM; Torstensson R; Biberfeld G
    AIDS; 1989 Jan; 3(1):17-20. PubMed ID: 2469436
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of seroconversion panels to estimate delay in detection of anti-human immunodeficiency virus antibodies by enzyme-linked immunosorbent assay of pooled compared to singleton serum samples.
    Novack L; Galai N; Yaari A; Orgel M; Shinar E; Sarov B
    J Clin Microbiol; 2006 Aug; 44(8):2909-13. PubMed ID: 16891511
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Feasibility of pooled-sample testing for the detection of porcine reproductive and respiratory syndrome virus antibodies on serum samples by ELISA.
    Rovira A; Cano JP; Muñoz-Zanzi C
    Vet Microbiol; 2008 Jul; 130(1-2):60-8. PubMed ID: 18243590
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rapid HIV versus enzyme-linked immunosorbent assay screening in a low-risk Mexican American population presenting in labor: a cost-effectiveness analysis.
    Doyle NM; Levison JE; Gardner MO
    Am J Obstet Gynecol; 2005 Sep; 193(3 Pt 2):1280-5. PubMed ID: 16157152
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of human immunodeficiency virus seroprevalence in population surveys using pooled sera.
    Kline RL; Brothers TA; Brookmeyer R; Zeger S; Quinn TC
    J Clin Microbiol; 1989 Jul; 27(7):1449-52. PubMed ID: 2768435
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the indirect immunofluorescence assay with western blot for the detection of HIV antibody.
    Abraham P; Babu PG; John TJ
    Indian J Med Res; 1994 Apr; 99():143-8. PubMed ID: 7927564
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Strategies for laboratory HIV testing: an examination of alternative approaches not requiring Western blot.
    Sato PA; Maskill WJ; Tamashiro H; Heymann DL
    Bull World Health Organ; 1994; 72(1):129-34. PubMed ID: 8131248
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Sensitivity and specificity of pooled versus individual sera in a human immunodeficiency virus antibody prevalence study.
    Cahoon-Young B; Chandler A; Livermore T; Gaudino J; Benjamin R
    J Clin Microbiol; 1989 Aug; 27(8):1893-5. PubMed ID: 2504779
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Utilization of used human immunodeficiency virus ELISA microplates & surplus reagents for HIV antibody testing.
    Makhija SK; Dhanvijay AG; Pathak AA; Saoji AM
    Indian J Med Res; 1995 Oct; 102():159-61. PubMed ID: 8543359
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Feasibility of pooling sera for HIV-1 viral RNA to diagnose acute primary HIV-1 infection and estimate HIV incidence.
    Quinn TC; Brookmeyer R; Kline R; Shepherd M; Paranjape R; Mehendale S; Gadkari DA; Bollinger R
    AIDS; 2000 Dec; 14(17):2751-7. PubMed ID: 11125894
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Successful use of pooled sera to determine HIV-1 seroprevalence in Zaire with development of cost-efficiency models.
    Behets F; Bertozzi S; Kasali M; Kashamuka M; Atikala L; Brown C; Ryder RW; Quinn TC
    AIDS; 1990 Aug; 4(8):737-41. PubMed ID: 2124494
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of the World Health Organisation antibody-testing strategy for the individual patient diagnosis of HIV infection (strategy III).
    Martin DJ; Blackburn NK; O'Connell KF; Brant ET; Goetsch EA
    S Afr Med J; 1995 Sep; 85(9):877-80. PubMed ID: 8545748
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparative evaluation of 36 commercial assays for detecting antibodies to HIV.
    Van Kerckhoven I; Vercauteren G; Piot P; van der Groen G
    Bull World Health Organ; 1991; 69(6):753-60. PubMed ID: 1786625
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of HIV-1 p24 antigen by signal-amplification-boosted ELISA of heat-denatured plasma is a simple and inexpensive alternative to tests for viral RNA.
    Schüpbach J
    AIDS Rev; 2002; 4(2):83-92. PubMed ID: 12152521
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of HIV serial and parallel serologic testing algorithms in Abidjan, Côte d'Ivoire.
    Nkengasong JN; Maurice C; Koblavi S; Kalou M; Yavo D; Maran M; Bile C; N'guessan K; Kouadio J; Bony S; Wiktor SZ; Greenberg AE
    AIDS; 1999 Jan; 13(1):109-17. PubMed ID: 10207552
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.