These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 8490086)

  • 1. [Fretting in modular design implant systems].
    Willmann G
    Biomed Tech (Berl); 1993 Mar; 38(3):48-52. PubMed ID: 8490086
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Load bearing capacity of CFK hip prosthesis with ceramic femoral heads].
    Früh HJ; Kaddick C; Willmann G
    Biomed Tech (Berl); 1997 Dec; 42(12):369-73. PubMed ID: 9487749
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [20 years aluminum oxide ceramics for medical applications].
    Willmann G
    Biomed Tech (Berl); 1994 Apr; 39(4):73-8. PubMed ID: 8018814
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements.
    Hallab NJ; Messina C; Skipor A; Jacobs JJ
    J Orthop Res; 2004 Mar; 22(2):250-9. PubMed ID: 15013082
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Otto Aufranc Award: Large Heads Do Not Increase Damage at the Head-neck Taper of Metal-on-polyethylene Total Hip Arthroplasties.
    Triantafyllopoulos GK; Elpers ME; Burket JC; Esposito CI; Padgett DE; Wright TM
    Clin Orthop Relat Res; 2016 Feb; 474(2):330-8. PubMed ID: 26208607
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Modular to Monoblock: Difficulties of Detaching the M(2)a-Magnum(TM) Head Are Common in Metal-on-metal Revisions.
    Mäntymäki H; Mäkelä KT; Vahlberg T; Hirviniemi J; Niinimäki T
    Clin Orthop Relat Res; 2016 Sep; 474(9):1999-2005. PubMed ID: 26940470
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ceramic Heads Decrease Metal Release Caused by Head-taper Fretting and Corrosion.
    Kocagoz SB; Underwood RJ; MacDonald DW; Gilbert JL; Kurtz SM
    Clin Orthop Relat Res; 2016 Apr; 474(4):985-94. PubMed ID: 26847452
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fretting and Corrosion Damage in Retrieved Metal-on-Polyethylene Modular Total Hip Arthroplasty Systems: What Is the Importance of Femoral Head Size?
    Siljander MP; Baker EA; Baker KC; Salisbury MR; Thor CC; Verner JJ
    J Arthroplasty; 2018 Mar; 33(3):931-938. PubMed ID: 29113756
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Trunnionosis: Does Head Size Affect Fretting and Corrosion in Total Hip Arthroplasty?
    Del Balso C; Teeter MG; Tan SC; Howard JL; Lanting BA
    J Arthroplasty; 2016 Oct; 31(10):2332-6. PubMed ID: 27067470
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Spontaneous modular femoral head dissociation complicating total hip arthroplasty.
    Talmo CT; Sharp KG; Malinowska M; Bono JV; Ward DM; LaReau J
    Orthopedics; 2014 Jun; 37(6):e592-5. PubMed ID: 24972443
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fretting and Corrosion Damage in Taper Adapter Sleeves for Ceramic Heads: A Retrieval Study.
    MacDonald DW; Chen AF; Lee GC; Klein GR; Mont MA; Kurtz SM; ; Cates HE; Kraay MJ; Rimnac CM
    J Arthroplasty; 2017 Sep; 32(9):2887-2891. PubMed ID: 28668212
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of Seating Load Magnitude on Incremental Cyclic Fretting Corrosion in 5°40' Mixed Alloy Modular Taper Junctions.
    Pierre D; Swaminathan V; Scholl LY; TenHuisen K; Gilbert JL
    J Arthroplasty; 2018 Jun; 33(6):1953-1961. PubMed ID: 29486910
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Retrieval Analysis of Neck-Stem Coupling in Modular Hip Prostheses.
    Su SL; Koch CN; Nguyen TM; Burket JC; Wright TM; Westrich GH
    J Arthroplasty; 2017 Jul; 32(7):2301-2306. PubMed ID: 28262451
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Does the Additional Articulation in Retrieved Bipolar Hemiarthroplasty Implants Decrease Trunnionosis Compared to Total Hip Arthroplasty?
    Del Balso C; Teeter MG; Tan SC; Lanting BA; Howard JL
    J Arthroplasty; 2018 Jan; 33(1):268-272. PubMed ID: 29033155
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The use of a proximal femoral nail as a hip prosthesis: A biomechanical analysis of a newly designed implant.
    Konya MN; Korkusuz F; Maralcan G; Demir T; Aslan A
    Proc Inst Mech Eng H; 2018 Feb; 232(2):200-206. PubMed ID: 29298621
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Damage analysis illustrated by two cases of broken ceramic inserts. Recommendations for avoiding breakages caused by handling].
    Steinhauser E; Bader R; Mittelmeier W
    Orthopade; 2004 Mar; 33(3):332-7. PubMed ID: 15007557
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vitro simulation of fretting-corrosion in hip implant modular junctions: The influence of pH.
    Royhman D; Patel M; Jacobs JJ; Wimmer MA; Hallab NJ; Mathew MT
    Med Eng Phys; 2018 Feb; 52():1-9. PubMed ID: 29290499
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The onset of fretting at the head-stem connection in hip arthroplasty is affected by head material and trunnion design under simulated corrosion conditions.
    Rowan FE; Wach A; Wright TM; Padgett DE
    J Orthop Res; 2018 Jun; 36(6):1630-1636. PubMed ID: 29319895
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of impact assembly on the fretting corrosion of modular hip tapers.
    Mroczkowski ML; Hertzler JS; Humphrey SM; Johnson T; Blanchard CR
    J Orthop Res; 2006 Feb; 24(2):271-9. PubMed ID: 16435360
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Femoral stem fracture and in vivo corrosion of retrieved modular femoral hips.
    Huot Carlson JC; Van Citters DW; Currier JH; Bryant AM; Mayor MB; Collier JP
    J Arthroplasty; 2012 Aug; 27(7):1389-1396.e1. PubMed ID: 22209042
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.