These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

190 related articles for article (PubMed ID: 8504539)

  • 1. Analytical evaluation of i-STAT Portable Clinical Analyzer and use by nonlaboratory health-care professionals.
    Jacobs E; Vadasdi E; Sarkozi L; Colman N
    Clin Chem; 1993 Jun; 39(6):1069-74. PubMed ID: 8504539
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the i-STAT system: a portable chemistry analyzer for the measurement of sodium, potassium, chloride, urea, glucose, and hematocrit.
    Mock T; Morrison D; Yatscoff R
    Clin Biochem; 1995 Apr; 28(2):187-92. PubMed ID: 7628079
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Laboratory evaluation of the Beckman Synchron CX3 clinical chemistry analyzer.
    Peake MJ; Pejakovic M; White GH
    Clin Chem; 1988 Feb; 34(2):404-7. PubMed ID: 3124982
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance of Gem Premier blood gas/electrolyte analyzer evaluated.
    Jacobs E; Nowakowski M; Colman N
    Clin Chem; 1993 Sep; 39(9):1890-3. PubMed ID: 8375066
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of i-STAT portable clinical analyzer in a hemodialysis unit.
    Gault MH; Harding CE
    Clin Biochem; 1996 Apr; 29(2):117-24. PubMed ID: 8601319
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A clinical chemistry analyzer evaluated by NCCLS guidelines for use in a military field laboratory unit.
    Sullinger J; Garrett PE
    Clin Chem; 1989 Nov; 35(11):2223-6. PubMed ID: 2582620
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of i-STAT portable clinical analyzer in a neonatal and pediatric intensive care unit.
    Murthy JN; Hicks JM; Soldin SJ
    Clin Biochem; 1997 Jul; 30(5):385-9. PubMed ID: 9253514
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Axon clinical chemistry analyzer evaluated according to ECCLS protocol.
    Brenna S; Prencipe L
    Clin Chem; 1992 Oct; 38(10):2096-100. PubMed ID: 1394998
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of the i-STAT Portable Clinical Analyzer for point-of-care blood testing in the intensive care units of a university children's hospital.
    Papadea C; Foster J; Grant S; Ballard SA; Cate JC; Southgate WM; Purohit DM
    Ann Clin Lab Sci; 2002; 32(3):231-43. PubMed ID: 12175085
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of a novel point-of-care system, the i-STAT portable clinical analyzer.
    Erickson KA; Wilding P
    Clin Chem; 1993 Feb; 39(2):283-7. PubMed ID: 8432019
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the i-STAT portable clinical analyzer for use in a helicopter.
    Burritt MF; Santrach PJ; Hankins DG; Herr D; Newton NC
    Scand J Clin Lab Invest Suppl; 1996; 224():121-8. PubMed ID: 8865426
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Blood values of juvenile northern elephant seals (Mirounga angustirostris) obtained using a portable clinical analyzer.
    Larsen RS; Haulena M; Grindem CB; Gulland FM
    Vet Clin Pathol; 2002; 31(3):106-10. PubMed ID: 12189595
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the Beckman Synchron CX4 clinical chemistry analyzer in a hospital laboratory.
    Ambus T; Korogyi N; DeCampos F; Groom B; Innanen VT
    J Clin Lab Anal; 1990; 4(2):120-5. PubMed ID: 2313469
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multicenter study of whole-blood creatinine, total carbon dioxide content, and chemistry profiling for laboratory and point-of-care testing in critical care in the United States.
    Kost GJ; Vu HT; Inn M; DuPlantier R; Fleisher M; Kroll MH; Spinosa JC
    Crit Care Med; 2000 Jul; 28(7):2379-89. PubMed ID: 10921568
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [The i-STAT analyzer. A new, hand-held device for the bedside determination of hematocrit, blood gases, and electrolytes].
    Schneider J; Dudziak R; Westphal K; Vettermann J
    Anaesthesist; 1997 Aug; 46(8):704-14. PubMed ID: 9382209
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Point-of-care glucose testing in the neonatal intensive care unit is facilitated by the use of the Ames Glucometer Elite electrochemical glucose meter.
    Innanen VT; DeLand ME; deCampos FM; Dunn MS
    J Pediatr; 1997 Jan; 130(1):151-5. PubMed ID: 9003866
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Portable blood gas and electrolyte analyzer evaluated in a multiinstitutional study.
    Lindemans J; Hoefkens P; van Kessel AL; Bonnay M; Külpmann WR; van Suijlen JD
    Clin Chem; 1999 Jan; 45(1):111-7. PubMed ID: 9895346
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparability of point-of-care whole-blood electrolyte and substrate testing using a Stat Profile Critical Care Xpress analyzer and standard laboratory methods.
    Flegar-Mestrić Z; Perkov S
    Clin Chem Lab Med; 2006; 44(7):898-903. PubMed ID: 16776641
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Extended clinical trial and evaluation of urea nitrogen determination with the Ektachem GLU/BUN analyzer.
    Bandi ZL; Fuller JB; Bee DE; James GP
    Clin Chem; 1981 Mar; 27(3):480-5. PubMed ID: 7008969
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Airborne and rescue point-of-care testing.
    Herr DM; Newton NC; Santrach PJ; Hankins DG; Burritt MF
    Am J Clin Pathol; 1995 Oct; 104(4 Suppl 1):S54-8. PubMed ID: 7484950
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.