These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 8514355)

  • 1. Determination of formaldehyde in indoor air by a solid sorbent technique.
    Georghiou PE; Winsor L; Sliwinski J; Shirtliffe CJ
    IARC Sci Publ; 1993; (109):251-5. PubMed ID: 8514355
    [No Abstract]   [Full Text] [Related]  

  • 2. Determination of formaldehyde in indoor air by a liquid sorbent technique.
    Georghiou PE; Winsor L; Sliwinski JF; Shirtliffe CJ
    IARC Sci Publ; 1993; (109):245-50. PubMed ID: 8514354
    [No Abstract]   [Full Text] [Related]  

  • 3. [Development and performance evaluation for a solid phase adsorption gas sampler of formaldehyde in indoor air].
    Yao XY; Wang W; Chen YL; Wang Y; Qi Q
    Wei Sheng Yan Jiu; 2005 Jul; 34(4):410-2. PubMed ID: 16229260
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An evaluation of the effect of source and concentration on three methods for the measurement of formaldehyde in indoor air.
    Beck SW; Stock TH
    Am Ind Hyg Assoc J; 1990 Jan; 51(1):14-21; discussion 22. PubMed ID: 2301250
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sampling strategies for indoor air analyses. COST 613 document.
    van de Wiel HJ; Mølhave L
    IARC Sci Publ; 1993; (109):96-117. PubMed ID: 8514374
    [No Abstract]   [Full Text] [Related]  

  • 6. Determination of pesticides and polychlorinated biphenyls in indoor air by gas chromatography.
    Lewis RG
    IARC Sci Publ; 1993; (109):353-76. PubMed ID: 8514368
    [No Abstract]   [Full Text] [Related]  

  • 7. Determination of organic solvent vapours in indoor air using charcoal adsorption and gas chromatography.
    Leichnitz K
    IARC Sci Publ; 1993; (109):211-20. PubMed ID: 8514350
    [No Abstract]   [Full Text] [Related]  

  • 8. Indoor air exchange and ventilation rate.
    Woods JE; Rask DR
    IARC Sci Publ; 1993; (109):377-84. PubMed ID: 8514369
    [No Abstract]   [Full Text] [Related]  

  • 9. Determination of radon and decay products in air by alpha track techniques.
    Urban M
    IARC Sci Publ; 1993; (109):163-72. PubMed ID: 8390402
    [No Abstract]   [Full Text] [Related]  

  • 10. Potential health risks from exposure to indoor formaldehyde.
    Lemus R; Abdelghani AA; Akers TG; Horner WE
    Rev Environ Health; 1998; 13(1-2):91-8. PubMed ID: 9718624
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of carbon monoxide in indoor air with a direct-reading instrument.
    Mage DT
    IARC Sci Publ; 1993; (109):342-5. PubMed ID: 8514366
    [No Abstract]   [Full Text] [Related]  

  • 12. Study of the current status and factors that influence indoor air pollution in 138 houses in the urban area in Xi'an.
    Liu J; Guo Y; Pan X
    Ann N Y Acad Sci; 2008 Oct; 1140():246-55. PubMed ID: 18991922
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Occupational exposure to formaldehyde in three pathology departments].
    Perdelli F; Spagnolo AM; Cristina ML; Sartini M; Dallera M; Ottria G; Orlando P
    Ann Ig; 2006; 18(6):481-90. PubMed ID: 17228606
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biosensing of an indoor volatile organic compound on the basis of fungal growth.
    Seo J; Kato S; Tatsuma T; Chino S; Takada K; Notsu H
    Chemosphere; 2008 Jul; 72(9):1286-91. PubMed ID: 18555511
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Formaldehyde in air of indoor and outdoor environments of urban area, relationships man's exposure].
    Fuselli S; Zanetti C
    Ann Ist Super Sanita; 2006; 42(3):365-8. PubMed ID: 17124360
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Portable formaldehyde monitoring device using porous glass sensor and its applications in indoor air quality studies.
    Maruo YY; Nakamura J
    Anal Chim Acta; 2011 Sep; 702(2):247-53. PubMed ID: 21839205
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Continuous filter method for radon daughters.
    Hagberg N; Swedjemark GA
    IARC Sci Publ; 1993; (109):180-4. PubMed ID: 8390404
    [No Abstract]   [Full Text] [Related]  

  • 18. [Formaldehyde--toxicologic aspects].
    Rosskamp E
    Schriftenr Ver Wasser Boden Lufthyg; 1995; 95():51-8. PubMed ID: 7777817
    [No Abstract]   [Full Text] [Related]  

  • 19. Effect of environmental conditions on re-emission of formaldehyde from textile materials.
    Wiglusz R; Sitko E; Jarnuszkiewicz I
    Bull Inst Marit Trop Med Gdynia; 1995; 46(1-4):53-8. PubMed ID: 8727469
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Levels and determinants of formaldehyde, acetaldehyde, and acrolein in residential indoor air in Prince Edward Island, Canada.
    Gilbert NL; Guay M; David Miller J; Judek S; Chan CC; Dales RE
    Environ Res; 2005 Sep; 99(1):11-7. PubMed ID: 16053923
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.