BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 8523009)

  • 1. Factors influencing pressurization of the femoral canal during cemented total hip arthroplasty.
    Maltry JA; Noble PC; Kamaric E; Tullos HS
    J Arthroplasty; 1995 Aug; 10(4):492-7. PubMed ID: 8523009
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vitro and in vivo studies of pressurization of femoral cement in total hip arthroplasty.
    Davies JP; Harris WH
    J Arthroplasty; 1993 Dec; 8(6):585-91. PubMed ID: 8301275
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pressurization and centralization enhance the quality and reproducibility of cement mantles.
    Noble PC; Collier MB; Maltry JA; Kamaric E; Tullos HS
    Clin Orthop Relat Res; 1998 Oct; (355):77-89. PubMed ID: 9917593
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of a polyglycolide lactide cement plug restrictor in total hip arthroplasty.
    Yee AJ; Binnington AG; Hearn T; Protzner K; Fornasier VL; Davey JR
    Clin Orthop Relat Res; 1999 Jul; (364):254-66. PubMed ID: 10416416
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Femoral cement pressurization in hip arthroplasty: a comparison of 3 systems.
    Munro NA; Nicol M; Selvaraj S; Hussain SM; Finlayson DF
    J Arthroplasty; 2007 Sep; 22(6):893-901. PubMed ID: 17826282
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro performance of intramedullary cement restrictors in total hip arthroplasty.
    Heisel C; Norman T; Rupp R; Pritsch M; Ewerbeck V; Breusch SJ
    J Biomech; 2003 Jun; 36(6):835-43. PubMed ID: 12742451
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Femoral stem insertion generates high bone cement pressurization.
    Churchill DL; Incavo SJ; Uroskie JA; Beynnon BD
    Clin Orthop Relat Res; 2001 Dec; (393):335-44. PubMed ID: 11764367
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The femoral stent. Surgical technique for a new method of cementing the femoral component in the presence of a large cortical defect.
    Freiberg AA; Harris WH
    Am J Orthop (Belle Mead NJ); 1995 Jun; 24(6):501-3. PubMed ID: 7670875
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Femoral cement pressurization during total hip arthroplasty. The role of different femoral stems with reference to stem size and shape.
    Bourne RB; Oh I; Harris WH
    Clin Orthop Relat Res; 1984 Mar; (183):12-6. PubMed ID: 6697578
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Occlusion and stability of synthetic femoral canal plugs used in cemented hip arthroplasty.
    Johnson JA; Johnston D; el Hawary R; Tan SR; Wong LA; Gross M
    J Appl Biomater; 1995; 6(3):213-8. PubMed ID: 7492814
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The femoral cement compactor. An improvement in cementing technique in total hip replacement.
    Oh I; Bourne RB; Harris WH
    J Bone Joint Surg Am; 1983 Dec; 65(9):1335-8. PubMed ID: 6654945
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel technique for femoral canal occlusion during cement pressurization in proximal femoral arthroplasty.
    Holt G; Panousis K; Mohammed A; Patil S; Meek RM
    J Arthroplasty; 2012 Jan; 27(1):129-33. PubMed ID: 22152980
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A plastic intermedullary plug for total hip arthroplasty.
    Mallory TH
    Clin Orthop Relat Res; 1981; (155):37-40. PubMed ID: 7226628
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assessment of cement introduction and pressurization techniques.
    Dunne NJ; Orr JF; Beverland DE
    Proc Inst Mech Eng H; 2004; 218(1):11-25. PubMed ID: 14982342
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of fixation of the femoral component without cement and fixation with use of a bone-vacuum cementing technique for the prevention of fat embolism during total hip arthroplasty. A prospective, randomized clinical trial.
    Pitto RP; Koessler M; Kuehle JW
    J Bone Joint Surg Am; 1999 Jun; 81(6):831-43. PubMed ID: 10391548
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An investigation of the performance of Biostop G and Hardinge bone plugs.
    Prendergast PJ; Birthistle P; Waide DV; Kumar NV
    Proc Inst Mech Eng H; 1999; 213(4):361-5. PubMed ID: 10466367
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Impacted particulate allograft for femoral revision total hip arthroplasty. In vitro mechanical stability and effects of cement pressurization.
    Berzins A; Sumner DR; Wasielewski RC; Galante JO
    J Arthroplasty; 1996 Aug; 11(5):500-6. PubMed ID: 8872566
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Changes in femoral cortical porosity after reaming and intramedullary canal preparation in a canine model.
    Syed KA; Kuzyk PR; Yoo DJ; Zdero R; Richards RR; Schemitsch EH
    J Arthroplasty; 2013 Feb; 28(2):368-73. PubMed ID: 22552219
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A cement fixation system for total hip arthroplasty.
    Oh I; Harris WH
    Clin Orthop Relat Res; 1982 Apr; (164):221-9. PubMed ID: 7067290
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of femoral neck length, stem size, and body weight on strains in the proximal cement mantle.
    Harrington MA; O'Connor DO; Lozynsky AJ; Kovach I; Harris WH
    J Bone Joint Surg Am; 2002 Apr; 84(4):573-9. PubMed ID: 11940617
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.