These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 8530709)

  • 101. Evaluation of different screw fixation techniques and screw diameters in sagittal split ramus osteotomy: finite element analysis method.
    Sindel A; Demiralp S; Colok G
    J Oral Rehabil; 2014 Sep; 41(9):683-91. PubMed ID: 24889187
    [TBL] [Abstract][Full Text] [Related]  

  • 102. In vitro evaluation of conventional and locking miniplate/screw systems for the treatment of mandibular angle fractures.
    Ribeiro-Junior PD; Magro-Filho O; Shastri KA; Papageorge MB
    Int J Oral Maxillofac Surg; 2010 Nov; 39(11):1109-14. PubMed ID: 20655176
    [TBL] [Abstract][Full Text] [Related]  

  • 103. Biomechanical evaluation of a T-shaped miniplate fixation of a modified sagittal split ramus osteotomy with buccal step, a new technique for mandibular orthognathic surgery.
    Aymach Z; Nei H; Kawamura H; Bell W
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2011 Jan; 111(1):58-63. PubMed ID: 20580286
    [TBL] [Abstract][Full Text] [Related]  

  • 104. Mechanical evaluation of the use of conventional and locking miniplate/screw systems used in sagittal split ramus osteotomy.
    Vieira Santos ZTB; Goulart DR; Sigua-Rodriguez EA; Pozzer L; Olate S; Albergaria-Barbosa JR
    J Korean Assoc Oral Maxillofac Surg; 2017 Apr; 43(2):77-82. PubMed ID: 28462190
    [TBL] [Abstract][Full Text] [Related]  

  • 105. A simple method with a sterilized surgical glove for removal of stripped screw.
    Sugiyama S; Iwai T; Honda K; Mitsudo K
    J Stomatol Oral Maxillofac Surg; 2022 Jun; 123(3):e43-e44. PubMed ID: 34517156
    [TBL] [Abstract][Full Text] [Related]  

  • 106. New technique for removing bone covering miniplates and screws.
    Kelm RC; Surmanowicz P; Lung KE; Davis CM
    Br J Oral Maxillofac Surg; 2020 Nov; 58(9):e119-e121. PubMed ID: 32654799
    [TBL] [Abstract][Full Text] [Related]  

  • 107. Stability of the mandible after bilateral sagittal split osteotomy: Comparison between positioning screws and plate.
    Nooh N
    Saudi Dent J; 2009 Oct; 21(3):123-6. PubMed ID: 23960470
    [TBL] [Abstract][Full Text] [Related]  

  • 108. Experimental analysis of internal rigid fixation osteosynthesis performed with titanium bone screw and plate systems.
    Righi E; Carta M; Bruzzone AA; Lonardo PM; Marinaro E; Pastorino A
    J Craniomaxillofac Surg; 1996 Feb; 24(1):53-7. PubMed ID: 8707943
    [TBL] [Abstract][Full Text] [Related]  

  • 109. Bridging mandibular continuity defects with miniplates: an experimental study.
    Huh JY; Choi BH; Zhu SJ; Jung JH; Lee SH; You TM; Lee HJ; Li J
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2006 Sep; 102(3):307-11. PubMed ID: 16920538
    [TBL] [Abstract][Full Text] [Related]  

  • 110. Fixation of onlay bone grafts with lag screws.
    Beckers HL; Freitag V
    J Maxillofac Surg; 1980 Nov; 8(4):316-23. PubMed ID: 7007544
    [TBL] [Abstract][Full Text] [Related]  

  • 111. Complete breakage of three-dimensional miniplates: unusual complication of osteosynthesis after sagittal split osteotomy. Two case reports.
    Fujioka M; Fujii T; Hirano A
    Scand J Plast Reconstr Surg Hand Surg; 2000 Sep; 34(3):259-63. PubMed ID: 11020925
    [TBL] [Abstract][Full Text] [Related]  

  • 112. Photoelastic experiments on the implantation of a bone graft into the mandible with stable compression osteosynthesis.
    Ewers R; Schilli W
    Int J Oral Surg; 1979 Dec; 8(6):462-6. PubMed ID: 120345
    [TBL] [Abstract][Full Text] [Related]  

  • 113. Bone repair in mandibular body osteotomy after using 2.0 miniplate system--histological and histometric analysis in dogs.
    Sverzut CE; Lucas MA; Sverzut AT; Trivellato AE; Beloti MM; Rosa AL; de Oliveira PT
    Int J Exp Pathol; 2008 Apr; 89(2):91-7. PubMed ID: 18336526
    [TBL] [Abstract][Full Text] [Related]  

  • 114. Comparison of postoperative paresthesia after sagittal split osteotomy among different fixation methods: a one year follow-up study.
    Tabrizi R; Bakrani K; Bastami F
    J Korean Assoc Oral Maxillofac Surg; 2019 Aug; 45(4):215-219. PubMed ID: 31508354
    [TBL] [Abstract][Full Text] [Related]  

  • 115. FEM analysis of a new miniplate: stress distribution on the plate, screws and the bone.
    Nalbantgil D; Tozlu M; Ozdemir F; Oztoprak MO; Arun T
    Eur J Dent; 2012 Jan; 6(1):9-15. PubMed ID: 22229002
    [TBL] [Abstract][Full Text] [Related]  

  • 116. Patient-tailored plate for bone fixation and accurate 3D positioning in corrective osteotomy.
    Dobbe JG; Vroemen JC; Strackee SD; Streekstra GJ
    Med Biol Eng Comput; 2013 Feb; 51(1-2):19-27. PubMed ID: 23054377
    [TBL] [Abstract][Full Text] [Related]  

  • 117. Drilling holes for locking screws in challenging anatomy.
    Khan H; Mitchell K
    Ann R Coll Surg Engl; 2019 Jan; 101(1):69. PubMed ID: 29909674
    [No Abstract]   [Full Text] [Related]  

  • 118. Biomechanical evaluation of different fixation techniques following modified sagittal split ramus osteotomy using buccal step: An
    Warade PD; Kshirsagar R; Mishra P; Prasad P; Sardeshmukh A
    Natl J Maxillofac Surg; 2022; 13(3):443-448. PubMed ID: 36683918
    [TBL] [Abstract][Full Text] [Related]  

  • 119. Comparison of strengths of five internal fixation methods used after bilateral sagittal split ramus osteotomy: An
    Sarkarat F; Ahmady A; Farahmand F; Fateh A; Kahali R; Nourani A; Rakhshan V
    Dent Res J (Isfahan); 2020; 17(4):258-265. PubMed ID: 33282151
    [TBL] [Abstract][Full Text] [Related]  

  • 120.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.