These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 8538428)

  • 1. Microvenous thrombosis rates following anastomosis with vein grafting and a knotted suture.
    Zhang F; Ustüner T; Walker R; Buntic R; Lineaweaver WC
    Microsurgery; 1995; 16(8):528-32. PubMed ID: 8538428
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of nylon and polypropylene sutures in a microvenous thrombosis model.
    Ustüner TE; Zhang F; Lineaweaver WC
    Microsurgery; 1995; 16(8):533-5. PubMed ID: 8538429
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Experimental microvenous thrombosis following anastomosis with a knotted suture.
    Tonken HP; Zhang F; Yim KK; Gencosmanoglu R; Sudekum AE; Campagna-Pinto D; Newlin L; Buncke HJ; Lineaweaver WC
    Microsurgery; 1995; 16(2):98-102. PubMed ID: 7783612
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prosthetic microvenous grafting in the rat femoral vein.
    Bartels HL; van der Lei B; Robinson PH
    Lab Anim; 1993 Jan; 27(1):47-54. PubMed ID: 8437435
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The use of an absorbable collagen cover (NeuraWrap) improves patency of interpositional vein grafts.
    Bekler HI; Rosenwasser MP; Akilina Y; Bulut G
    Acta Orthop Traumatol Turc; 2010; 44(2):157-61. PubMed ID: 20676019
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The protective effect of vein cuffed anastomoses is not mechanical in origin.
    Norberto JJ; Sidawy AN; Trad KS; Jones BA; Neville RF; Najjar SF; Sidawy MK; DePalma RG
    J Vasc Surg; 1995 Apr; 21(4):558-64; discussion 564-6. PubMed ID: 7707561
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Microvenous grafts to arterial defects. The use of mechanical or suture anastomoses.
    Gilbert RW; Ragnarsson R; Berggren A; Ostrup L
    Arch Otolaryngol Head Neck Surg; 1989 Aug; 115(8):970-6. PubMed ID: 2751857
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prosthetic microvenous grafting into the femoral vein of the rat; considerations concerning the anastomotic technique.
    Robinson PH; van der Lei B; Jongebloed WL; Hoppen HJ; Pennings AJ
    Br J Plast Surg; 1989 Sep; 42(5):538-43. PubMed ID: 2804519
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of torsion on microvenous anastomotic patency in a rat model and early thrombolytic phenomenon.
    Bilgin SS; Topalan M; Ip WY; Chow SP
    Microsurgery; 2003; 23(4):381-6. PubMed ID: 12942531
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Modified anastomotic technique for 1 millimeter internal diameter polytetrafluoroethylene arterial grafts in the rat.
    Golding MJ; Harris JP; May J
    Microsurgery; 1992; 13(6):304-12. PubMed ID: 1453931
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Patency and healing of polymeric microvenous prostheses implanted into the rat femoral vein by means of the sleeve anastomotic technique.
    Robinson PH; van der Lei B; Schakenraad JM; Jongebloed WJ; Hoppen HJ; Pennings AJ; Nieuwenhuis P
    J Reconstr Microsurg; 1990 Jul; 6(3):287-92. PubMed ID: 2292792
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of venous flow alterations upon patency of rat femoral vein anastomoses.
    Cooley BC; Gould JS
    Microsurgery; 1992; 13(3):138-42. PubMed ID: 1598083
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Who needs extra time? Amniotic membrane wrapped pauci-suture model for rapid anastomoses
    Ercin BS; Bicer A; Yigitturk G; Cinar C; Cavusoglu T; Uyanikgil Y; Gurler T
    J Plast Surg Hand Surg; 2019 Apr; 53(2):89-96. PubMed ID: 30654665
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Modified crush-avulsion anastomosis model on the rat femoral vein.
    Fu K; Izquierdo R; Hubbard T; Fareed J
    Microsurgery; 1995; 16(8):536-41. PubMed ID: 8538430
    [TBL] [Abstract][Full Text] [Related]  

  • 15. New method for autogenous vein grafting with the telescoping anastomotic technique.
    Saitoh S; Nakatsuchi Y; Hart WS; Burkhalter WE
    Microsurgery; 1992; 13(1):11-8. PubMed ID: 1588804
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of the telescoping anastomotic technique with the end-to-end technique utilizing vein grafts for venous defects: short- and long-term results.
    Saitoh S; Kitagawa E; Nakatsuchi Y
    Microsurgery; 1995; 16(9):631-8. PubMed ID: 8747287
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new method of applying fibrin glue at the microvascular anastomotic site: the "paintbrush" technique.
    Padubidri AN; Browne E
    Microsurgery; 1996; 17(8):428-30. PubMed ID: 9393661
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fibrin glue-assisted end-to-side anastomosis of rat femoral vessels: comparison with conventional suture method.
    Padubidri AN; Browne E; Kononov A
    Ann Plast Surg; 1996 Jul; 37(1):41-7. PubMed ID: 8826591
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microvascular vein-graft patency in the rat model.
    Zhang F; Oliva A; Kao SD; Newlin L; Buncke HJ
    J Reconstr Microsurg; 1994 Jul; 10(4):223-7. PubMed ID: 7965995
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Anastomotic tissue response associated with expanded polytetrafluoroethylene access grafts constructed by using nonpenetrating clips.
    Dal Ponte DB; Berman SS; Patula VB; Kleinert LB; Williams SK
    J Vasc Surg; 1999 Aug; 30(2):325-33. PubMed ID: 10436453
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.