These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 8542232)

  • 1. Dose rates and energy spectra in the maze of a linear accelerator treatment room.
    Morgan S; Morgan HM; Lillicrap SC
    Br J Radiol; 1995 Nov; 68(815):1237-41. PubMed ID: 8542232
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Estimation of the dose at the maze entrance for x-rays from radiotherapy linear accelerators.
    Al-Affan IA
    Med Phys; 2000 Jan; 27(1):231-8. PubMed ID: 10659762
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dose reduction of scattered photons from concrete walls lined with lead: Implications for improvement in design of megavoltage radiation therapy facility mazes.
    Al-Affan IA; Hugtenburg RP; Bari DS; Al-Saleh WM; Piliero M; Evans S; Al-Hasan M; Al-Zughul B; Al-Kharouf S; Ghaith A
    Med Phys; 2015 Feb; 42(2):606-614. PubMed ID: 28102603
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dose reduction of scattered photons from concrete walls lined with lead: Implications for improvement in design of megavoltage radiation therapy facility mazes.
    Al-Affan IA; Hugtenburg RP; Bari DS; Al-Saleh WM; Piliero M; Evans S; Al-Hasan M; Al-Zughul B; Al-Kharouf S; Ghaith A
    Med Phys; 2015 Feb; 42(2):606-14. PubMed ID: 25771559
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A novel technique to optimise the length of a linear accelerator treatment room maze without compromising radiation protection.
    Al-Affan IAM; Evans SC; Qutub M; Hugtenburg RP
    J Radiol Prot; 2018 Mar; 38(1):48-60. PubMed ID: 28980530
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Neutron dose calculation at the maze entrance of medical linear accelerator rooms.
    Falcão RC; Facure A; Silva AX
    Radiat Prot Dosimetry; 2007; 123(3):283-7. PubMed ID: 17005540
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Radiation protection aspects of a new high-energy linear accelerator.
    O'Brien P; Michaels HB; Gillies B; Aldrich JE; Andrew JW
    Med Phys; 1985; 12(1):101-7. PubMed ID: 3919249
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The measurement of photoneutron dose in the vicinity of clinical linear accelerators.
    Rivera JC; Falcão RC; Dealmeida CE
    Radiat Prot Dosimetry; 2008; 130(4):403-9. PubMed ID: 18375468
    [TBL] [Abstract][Full Text] [Related]  

  • 9. New empirical formula for neutron dose level at the maze entrance of 15 MV medical accelerator facilities.
    Kim HS; Jang KW; Park YH; Kwon JW; Choi HS; Lee JK; Kim JK
    Med Phys; 2009 May; 36(5):1512-20. PubMed ID: 19544767
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ambient dose and dose rate measurements in the vicinity of Elekta Precise accelerators for radiation therapy.
    Zutz H; Hupe O
    Radiat Prot Dosimetry; 2014 Dec; 162(4):431-7. PubMed ID: 24379437
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the photoneutron field produced in a medical linear accelerator.
    Kim HS; Park YH; Koo BC; Kwon JW; Lee JS; Choi HS
    Radiat Prot Dosimetry; 2007; 123(3):323-8. PubMed ID: 17077093
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Neutron dose rate evaluation for medical linear accelerators.
    Facure A; Falcão RC; Da Silva AX; Crispim VR
    Radiat Prot Dosimetry; 2004; 111(1):101-3. PubMed ID: 15367778
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Radiation protection of linac bunkers. A user-friendly approach.
    Sørensen TH; Olsen KJ; Behrens CF
    Radiat Prot Dosimetry; 2015 Jul; 165(1-4):503-5. PubMed ID: 25836699
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of the photon spectrum of a therapeutic linear accelerator near the maze entrance: Comparison of Monte Carlo modeling and measurements using scintillation detectors corrected for pulse pile-up.
    Qutub MAZ; Hugtenburg RP; Al-Affan IAM
    Med Phys; 2020 Sep; 47(9):4522-4530. PubMed ID: 32469079
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A versatile program for the calculation of linear accelerator room shielding.
    Hassan ZE; Farag NM; Elshemey WM
    J Radiol Prot; 2018 Jun; 38(2):666-677. PubMed ID: 29565027
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monte Carlo estimation of photoneutrons contamination from high-energy X-ray medical accelerators in treatment room and maze: a simplified model.
    Zabihzadeh M; Ay MR; Allahverdi M; Mesbahi A; Mahdavi SR; Shahriari M
    Radiat Prot Dosimetry; 2009 Jul; 135(1):21-32. PubMed ID: 19483207
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement and calculation of neutron leakage from a medical electron accelerator.
    Uwamino Y; Nakamura T; Ohkubo T; Hara A
    Med Phys; 1986; 13(3):374-84. PubMed ID: 3088411
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Room scattered neutrons.
    McCall RC; McGinley PH; Huffman KE
    Med Phys; 1999 Feb; 26(2):206-7. PubMed ID: 10076975
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Contribution of activation products to occupational exposure following treatment using high-energy photons in radiotherapy.
    Petrović N; Krestić-Vesović J; Stojanović D; Ciraj-Bjelac O; Lazarević D; Kovacević M
    Radiat Prot Dosimetry; 2011 Jan; 143(1):109-12. PubMed ID: 20947589
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The need to update NCRP 151 data for 10 MV linear accelerator bunker shielding based on new measurements and Monte Carlo simulations.
    Rijken J; Towns S; Healy B
    J Radiol Prot; 2021 Nov; 41(4):. PubMed ID: 34624879
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.