These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 8547886)

  • 1. An improved 191Os/191mIr generator using a hybrid anion exchanger.
    Packard AB; Day PJ; Treves ST
    Nucl Med Biol; 1995 Oct; 22(7):887-91. PubMed ID: 8547886
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Osmium-191/iridium-191m generator based on silica gel impregnated with tridodecylmethylammonium chloride.
    Issachar D; Abrashkin S; Weininger J; Zemach D; Lubin E; Hellman C; Trumper J
    J Nucl Med; 1989 Apr; 30(4):538-41. PubMed ID: 2544695
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of osmium(II)-nitrosyl complexes as a method to increase the yield of the 191Os-191mIr generator.
    Packard AB; Lambert C
    Int J Rad Appl Instrum B; 1992 Apr; 19(3):357-62. PubMed ID: 1629025
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An osmium-191/iridium-191m radionuclide generator using an oxalato osmate parent complex.
    Packard AB; Treves ST; O'Brien GM; Lim KS
    J Nucl Med; 1987 Oct; 28(10):1571-6. PubMed ID: 3655910
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The development of an 191Os----191mIr generator using an osmium chelate parent complex--I. Trans-dioxobismalonatoosmate(VI).
    Packard AB; O'Brien GM; Treves S
    Int J Rad Appl Instrum B; 1986; 13(5):519-22. PubMed ID: 3818315
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new osmium-191/iridium-191m radionuclide generator system using activated carbon.
    Brihaye C; Butler TA; Knapp FF; Guillaume M; Watson EE; Stabin MG
    J Nucl Med; 1986 Mar; 27(3):380-7. PubMed ID: 3712057
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An improved 191Os-191mIr generator for radionuclide angiocardiography.
    Hnatowich DJ; Kulprathipanja S; Treves S
    Radiology; 1977 Apr; 123(1):189-94. PubMed ID: 403568
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Angiocardiography with iridium-191m: an ultrashort-lived radionuclide (T1/2 4.9 sec).
    Treves S; Kulprathipanja S; Hnatowich DJ
    Circulation; 1976 Aug; 54(2):275-9. PubMed ID: 820485
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 191Os/191mIr-generator for studying arterial blood flow in experimental animal models.
    Kairemo KJ; Kestilä MS; Savolainen S; Korhola OA; Hiltunen JV; Svahn RI; Korppi-Tommola ET; Knapp FF; Brihaye C
    J Nucl Biol Med (1991); 1994 Dec; 38(4 Suppl 1):86-8. PubMed ID: 7632774
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of pH adjustment agents on the biologic behavior of osmium-191 impurity in iridium-191m generator eluates.
    Weininger J; Issachar D; Lubin E; Zabari M; Trumper J
    J Nucl Med; 1990 Apr; 31(4):523-5. PubMed ID: 2109051
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical usefulness of ultrashort-lived iridium-191m from a carbon-based generator system for the evaluation of the left ventricular function.
    Franken PR; Dobbeleir AA; Ham HR; Brihaye C; Guillaume M; Knapp FF; Vandevivere J
    J Nucl Med; 1989 Jun; 30(6):1025-31. PubMed ID: 2738684
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Rapid renal single-photon emission tomography by continuous infusion of iridium-191m.
    Treves ST; Fung L; Packard AB
    Eur J Nucl Med; 1999 May; 26(5):489-93. PubMed ID: 10382092
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new osmium-191 leads to iridium-191m generator.
    Cheng C; Treves S; Samuel A; Davis MA
    J Nucl Med; 1980 Dec; 21(12):1169-76. PubMed ID: 7441355
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [191mIr: distribution and retention in animal experiments].
    Kairemo KJ; Kestilä MS; Svahn RI; Hiltunen JV
    Nuklearmedizin; 1995 Jun; 34(3):115-7. PubMed ID: 7630744
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of ventricular function with first-pass iridium-191m radionuclide angiocardiography.
    Hellman C; Zafrir N; Shimoni A; Issachar D; Trumper J; Abrashkin S; Lubin E
    J Nucl Med; 1989 Apr; 30(4):450-7. PubMed ID: 2738675
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Study of the 192Os(d,2n) reaction for production of the therapeutic radionuclide 192Ir in no-carrier added form.
    Tárkányi F; Hermanne A; Takács S; Hilgers K; Kovalev SF; Ignatyuk AV; Qaim SM
    Appl Radiat Isot; 2007 Nov; 65(11):1215-20. PubMed ID: 17681800
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The use of iridium-191m for pulmonary blood flow imaging.
    Bocher M; Issachar D; Zabari M; Karger H; Chisin R
    Eur J Nucl Med; 1994 May; 21(5):427-31. PubMed ID: 8062848
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Iridium- 191 angiocardiography for the detection and quantitation of left-to-right shunting.
    Treves S; Cheng C; Samuel A; Lambrecht R; Babchyck B; Zimmerman R; Norwood W
    J Nucl Med; 1980 Dec; 21(12):1151-7. PubMed ID: 7192313
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of ultrashort-lived iridium-191m with technetium-99m for first pass radionuclide angiocardiographic evaluation of right and left ventricular function in adults.
    Heller GV; Treves ST; Parker JA; Duke LA; O'Brien GM; Davis RT; Fitzgibbon C; Packard AB
    J Am Coll Cardiol; 1986 Jun; 7(6):1295-302. PubMed ID: 3711486
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optimization of a Labeling and Kit Preparation Method for Ga-68 Labeled DOTATATE, Using Cation Exchange Resin Purified Ga-68 Eluates Obtained from a Tin Dioxide
    Prince D; Rossouw D; Rubow S
    Mol Imaging Biol; 2018 Dec; 20(6):1008-1014. PubMed ID: 29687322
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.