These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
87 related articles for article (PubMed ID: 8551997)
41. Low-level exposure to cadmium during the lifetime increases the risk of osteoporosis and fractures of the lumbar spine in the elderly: studies on a rat model of human environmental exposure. Brzóska MM; Moniuszko-Jakoniuk J Toxicol Sci; 2004 Dec; 82(2):468-77. PubMed ID: 15375291 [TBL] [Abstract][Full Text] [Related]
42. Motion characteristic of the normal lumbar spine in young adults: instantaneous axis of rotation and vertebral center motion analyses. Yoshioka T; Tsuji H; Hirano N; Sainoh S J Spinal Disord; 1990 Jun; 3(2):103-13. PubMed ID: 2134418 [TBL] [Abstract][Full Text] [Related]
43. Relevant Anatomic and Morphological Measurements of the Rat Spine: Considerations for Rodent Models of Human Spine Trauma. Jaumard NV; Leung J; Gokhale AJ; Guarino BB; Welch WC; Winkelstein BA Spine (Phila Pa 1976); 2015 Oct; 40(20):E1084-92. PubMed ID: 26731709 [TBL] [Abstract][Full Text] [Related]
44. A biomechanical investigation of vertebroplasty in osteoporotic compression fractures and in prophylactic vertebral reinforcement. Furtado N; Oakland RJ; Wilcox RK; Hall RM Spine (Phila Pa 1976); 2007 Aug; 32(17):E480-7. PubMed ID: 17762281 [TBL] [Abstract][Full Text] [Related]
45. [Biostatics in pathologically changed vertebral bodies]. Seyss R Med Klin; 1969 Aug; 64(32):1428-31. PubMed ID: 5801042 [No Abstract] [Full Text] [Related]
46. Biomechanical analysis of a new anterior spine implant for post-corpectomy instability. MacMillan M; Glowczewskie F J Spinal Disord; 1995 Feb; 8(1):56-61. PubMed ID: 7711370 [TBL] [Abstract][Full Text] [Related]
47. Prevalence of Poor Bone Quality in Women Undergoing Spinal Fusion Using Biomechanical-CT Analysis. Burch S; Feldstein M; Hoffmann PF; Keaveny TM Spine (Phila Pa 1976); 2016 Feb; 41(3):246-52. PubMed ID: 26352741 [TBL] [Abstract][Full Text] [Related]
48. Biomechanical changes after the augmentation of experimental osteoporotic vertebral compression fractures in the cadaveric thoracic spine. Kayanja MM; Togawa D; Lieberman IH Spine J; 2005; 5(1):55-63. PubMed ID: 15653085 [TBL] [Abstract][Full Text] [Related]
49. Effect of physiological loads on cortical and traditional pedicle screw fixation. Baluch DA; Patel AA; Lullo B; Havey RM; Voronov LI; Nguyen NL; Carandang G; Ghanayem AJ; Patwardhan AG Spine (Phila Pa 1976); 2014 Oct; 39(22):E1297-302. PubMed ID: 25099320 [TBL] [Abstract][Full Text] [Related]
50. Bone mineral density assessment using the EOS low-dose X-ray device: a feasibility study. Sapin E; Briot K; Kolta S; Gravel P; Skalli W; Roux C; Mitton D Proc Inst Mech Eng H; 2008 Nov; 222(8):1263-71. PubMed ID: 19143419 [TBL] [Abstract][Full Text] [Related]
51. Experimental determination of cervical spine mechanical properties. Gzik M; Wolanski W; Tejszerska D Acta Bioeng Biomech; 2008; 10(4):49-54. PubMed ID: 19385512 [TBL] [Abstract][Full Text] [Related]
52. Biomechanics of the spine. Aulisa L; Pitta L; Padua R; Ceccarelli E; Aulisa A; Leone A Rays; 2000; 25(1):11-8. PubMed ID: 10967631 [TBL] [Abstract][Full Text] [Related]
53. Determinants and heterogeneity of mechanical competence throughout the thoracolumbar spine of elderly women and men. Eckstein F; Fischbeck M; Kuhn V; Link TM; Priemel M; Lochmüller EM Bone; 2004 Aug; 35(2):364-74. PubMed ID: 15268885 [TBL] [Abstract][Full Text] [Related]
54. Abnormal response to physical activity in femurs after heterozygous inactivation of one allele of the Col2a1 gene for type II collagen in mice. Nieminen J; Sahlman J; Hirvonen T; Jämsä T; Tuukkanen J; Kovanen V; Kröger H; Jurvelin J; Arita M; Li SW; Prockop DJ; Hyttinen MM; Helminen HJ; Lapveteläinen T; Puustjärvi K Calcif Tissue Int; 2005 Aug; 77(2):104-12. PubMed ID: 15920676 [TBL] [Abstract][Full Text] [Related]
55. Wavelet-based characterization of vertebral trabecular bone structure from magnetic resonance images at 3 T compared with micro-computed tomographic measurements. Krug R; Carballido-Gamio J; Burghardt AJ; Haase S; Sedat JW; Moss WC; Majumdar S Magn Reson Imaging; 2007 Apr; 25(3):392-8. PubMed ID: 17371730 [TBL] [Abstract][Full Text] [Related]
56. A methodology for mechanical measurements of technical constants of trabecular bone. Yahia LH; Drouin G; Duval P Eng Med; 1988 Oct; 17(4):169-73. PubMed ID: 3224736 [No Abstract] [Full Text] [Related]
57. Spine function: a concert of many different players. Milz S J Anat; 2012 Dec; 221(6):479. PubMed ID: 23088595 [No Abstract] [Full Text] [Related]
58. Kinematic analysis and classification of vertebral motion. HOAG JM; KOSOK M; MOSER JR J Am Osteopath Assoc; 1960 Aug; 59():982-6 concl. PubMed ID: 14402118 [No Abstract] [Full Text] [Related]
59. Kinematic analysis and classification of vertebral motion. HOAG JM; KOSOK M; MOSER JR J Am Osteopath Assoc; 1960 Jul; 59():899-908 contd. PubMed ID: 14402117 [No Abstract] [Full Text] [Related]
60. A mathematical model for the study of the mechanics of the human vertebral column. Schultz AB; Galante JO J Biomech; 1970 Jul; 3(4):405-16. PubMed ID: 5521554 [No Abstract] [Full Text] [Related] [Previous] [Next] [New Search]