These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
99 related articles for article (PubMed ID: 8561087)
1. Exponentially adjusted moving mean procedure for quality control. An optimized patient sample control procedure. Smith FA; Kroft SH Am J Clin Pathol; 1996 Jan; 105(1):44-51. PubMed ID: 8561087 [TBL] [Abstract][Full Text] [Related]
2. Optimal procedures for detecting analytic bias using patient samples. Smith FA; Kroft SH Am J Clin Pathol; 1997 Sep; 108(3):254-68. PubMed ID: 9291452 [TBL] [Abstract][Full Text] [Related]
3. Moving standard deviation and moving sum of outliers as quality tools for monitoring analytical precision. Liu J; Tan CH; Badrick T; Loh TP Clin Biochem; 2018 Feb; 52():112-116. PubMed ID: 29107011 [TBL] [Abstract][Full Text] [Related]
4. Performance characteristics of Bull's multirule algorithm for the quality control of multichannel hematology analyzers. Lunetzky ES; Cembrowski GS Am J Clin Pathol; 1987 Nov; 88(5):634-8. PubMed ID: 3673945 [TBL] [Abstract][Full Text] [Related]
5. Relationship of quality goals and measurement performance to the selection of quality control procedures for multi-channel haematology analysers. Westgard JO; Cembrowski GS Eur J Haematol Suppl; 1990; 53():14-8. PubMed ID: 2279549 [TBL] [Abstract][Full Text] [Related]
6. Quality control of multichannel hematology analyzers: evaluation of Bull's algorithm. Cembrowski GS; Westgard JO Am J Clin Pathol; 1985 Mar; 83(3):337-45. PubMed ID: 3976570 [TBL] [Abstract][Full Text] [Related]
7. Use of medians and "average of normals" of patients' data for assessment of long-term analytical stability. Lott JA; Smith DA; Mitchell LC; Moeschberger ML Clin Chem; 1996 Jun; 42(6 Pt 1):888-92. PubMed ID: 8665680 [TBL] [Abstract][Full Text] [Related]
8. Design and assessment of average of normals (AON) patient data algorithms to maximize run lengths for automatic process control. Westgard JO; Smith FA; Mountain PJ; Boss S Clin Chem; 1996 Oct; 42(10):1683-8. PubMed ID: 8855154 [TBL] [Abstract][Full Text] [Related]
10. Design and evaluation of statistical control procedures: applications of a computer "quality control simulator" program. Westgard JO; Groth T Clin Chem; 1981 Sep; 27(9):1536-45. PubMed ID: 7261331 [TBL] [Abstract][Full Text] [Related]
11. Preserved blood versus patient data for quality control--Bull's algorithm revisited. Levy WC; Hay KL; Bull BS Am J Clin Pathol; 1986 Jun; 85(6):719-21. PubMed ID: 3706209 [TBL] [Abstract][Full Text] [Related]
12. Inefficacy of moving average algorithm as principal quality control procedure on Technicon System H6000. Tramacere P; Marocchi A; Gerthoux P; Beretta C; Brivio R; Mocarelli P Am J Clin Pathol; 1991 Feb; 95(2):218-21. PubMed ID: 1992611 [TBL] [Abstract][Full Text] [Related]
13. Comparison and optimization of various moving patient-based real-time quality control procedures for serum sodium. Li Y; Yu Q; Zhang X; Chen X J Clin Lab Anal; 2021 Oct; 35(10):e23985. PubMed ID: 34520584 [TBL] [Abstract][Full Text] [Related]
14. Serial correlation of quality control data--on the use of proper control charts. Winkel P; Zhang NF Scand J Clin Lab Invest; 2004; 64(3):195-203. PubMed ID: 15222629 [TBL] [Abstract][Full Text] [Related]
15. Internal quality control system for non-stationary, non-ergodic analytical processes based upon exponentially weighted estimation of process means and process standard deviation. Jansen RT; Laeven M; Kardol W Clin Chem Lab Med; 2002 Jun; 40(6):616-24. PubMed ID: 12211659 [TBL] [Abstract][Full Text] [Related]
16. Laboratory quality control: using patient data to assess analytical performance. Kazmierczak SC Clin Chem Lab Med; 2003 May; 41(5):617-27. PubMed ID: 12812257 [TBL] [Abstract][Full Text] [Related]
17. Verification of out-of-control situations detected by "average of normal" approach. Liu J; Tan CH; Loh TP; Badrick T Clin Biochem; 2016 Nov; 49(16-17):1248-1253. PubMed ID: 27452179 [TBL] [Abstract][Full Text] [Related]
18. Estimation of the optimal statistical quality control sampling time intervals using a residual risk measure. Hatjimihail AT PLoS One; 2009 Jun; 4(6):e5770. PubMed ID: 19513124 [TBL] [Abstract][Full Text] [Related]