These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 8565238)

  • 1. Marked interference of hyperglycemia in measurements of mean (red) cell volume by Technicon H analyzers.
    van Duijnhoven HL; Treskes M
    Clin Chem; 1996 Jan; 42(1):76-80. PubMed ID: 8565238
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Spurious elevation of the electronically determined mean corpuscular volume and hematocrit caused by hyperglycemia.
    Holt JT; DeWandler MJ; Arvan DA
    Am J Clin Pathol; 1982 May; 77(5):561-7. PubMed ID: 7081150
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of automated erythrocyte methodology in new world camelids using the ADVIA 2120 hematology analyzer.
    Viesselmann LC; Flatland B; Stokol T; Sisson S; Schaefer DMW
    Vet Clin Pathol; 2019 Jun; 48(2):239-249. PubMed ID: 31179576
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Increased electronic mean corpuscular volume induced by marked hyperglycemia.
    Morse EE; Kalache G; Germino W; Stockwell R
    Ann Clin Lab Sci; 1981; 11(2):184-7. PubMed ID: 7259094
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Inaccuracy in automated measurement of hematocrit and corpuscular indices in the presence of severe hyperglycemia.
    Strauchen JA; Alston W; Anderson J; Gustafson Z; Fajardo LF
    Blood; 1981 Jun; 57(6):1065-7. PubMed ID: 6784789
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quality control of multichannel hematology analyzers. Bivariate on-line comparison of MCV and MCH values for the detection of random errors.
    Kairisto V; Kouri T; Rajamäki A; Virtanen A; Uusipaikka E; Näntö V
    Am J Clin Pathol; 1992 May; 97(5):645-51. PubMed ID: 1575208
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Clinical reference values for laboratory hematology tests calculated using the iterative truncation method with correction: Part 1. Reference values for erythrocyte count, hemoglobin quantity, hematocrit and other erythrocyte parameters including MCV, MCH, MCHC and RDW].
    Shiga S; Koyanagi I; Kannagi R
    Rinsho Byori; 1990 Jan; 38(1):93-103. PubMed ID: 2308230
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Hypo- and hypernatremia results in inaccurate erythrocyte mean corpuscular volume measurement in vitro, when using Sysmex XE 2100.
    Philipsen JP; Madsen KV
    Scand J Clin Lab Invest; 2015 Nov; 75(7):588-94. PubMed ID: 26305422
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Determination by flow cytometry of reference values of erythrocyte parameters in aged subjects].
    Blain H; Lerouge S; Blain A; Lacomski D; Virion JM; Humbert JC; Jeandel C
    Presse Med; 2001 Apr; 30(16):779-84. PubMed ID: 11388147
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Standardization Committee for Haematology. External Quality Assurance Program for General Hematology. Evaluation of the 1994 results].
    Gutiérrez G; Jou JM; Carlos Reverter J; Martínez-Brotons F; Domingo A; Antonio Iriarte J; Remacha A; Rey J; Vives Corrons JL
    Sangre (Barc); 1996 Apr; 41(2):115-23. PubMed ID: 9045351
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Abnormalities of hematologic parameters in heavy drinkers and alcoholics.
    Seppä K; Sillanaukee P; Koivula T
    Alcohol Clin Exp Res; 1992 Feb; 16(1):117-21. PubMed ID: 1558291
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The erythrocyte indices of neonates, defined using data from over 12,000 patients in a multihospital health care system.
    Christensen RD; Jopling J; Henry E; Wiedmeier SE
    J Perinatol; 2008 Jan; 28(1):24-8. PubMed ID: 17972890
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of complete blood count results from a new, on-site hemocytometer compared with a laboratory-based hemocytometer.
    Despotis GJ; Alsoufiev A; Hogue CW; Zoys TN; Goodnough LT; Santoro SA; Kater KM; Barnes P; Lappas DG
    Crit Care Med; 1996 Jul; 24(7):1163-7. PubMed ID: 8674329
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Control cells for both electrical impedance and light scattering automated hematological analyzers: preparation from normal and thalassemic blood samples.
    Arnutti P; Bunyaratavej A; Patanapanyasat K; Chuansumrit A
    J Med Assoc Thai; 1997 Sep; 80 Suppl 1():S92-8. PubMed ID: 9347653
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accurate determination of mean cell volume by isotope dilution in erythrocyte populations with variable deformability.
    Marvel JS; Sutera SP; Krogstad DJ; Zarkowsky HS; Williamson JR
    Blood Cells; 1991; 17(3):497-512; discussion 513-5. PubMed ID: 1760558
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Practical experience with a quality control procedure using retained patient specimens on Technicon H1 and COULTER S 880.
    Rustad P; Lund PK
    Eur J Haematol Suppl; 1990; 53():19-21. PubMed ID: 2279550
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of age and gender on reference intervals of red blood cell distribution width (RDW) and mean red cell volume (MCV).
    Hoffmann JJ; Nabbe KC; van den Broek NM
    Clin Chem Lab Med; 2015 Nov; 53(12):2015-9. PubMed ID: 26536583
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hyperglycemic macrocytosis in electronically determined mean corpuscular volume. Use of three different automatic cell counters.
    Planas AT; Van Voolen GA; Kelly LA
    Ann Clin Lab Sci; 1985; 15(4):286-91. PubMed ID: 4037700
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of erythrocyte disorders with mean corpuscular volume (MCV) and red cell distribution width (RDW).
    Monzon CM; Beaver BD; Dillon TD
    Clin Pediatr (Phila); 1987 Dec; 26(12):632-8. PubMed ID: 3677532
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spurious red blood cell parameters due to serum cold agglutinins: observations on Ortho ELT-8 cell counter.
    Solanki DL; Blackburn BC
    Am J Clin Pathol; 1985 Feb; 83(2):218-22. PubMed ID: 3969960
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.