These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
142 related articles for article (PubMed ID: 8565545)
1. Spirometric versus Fick-derived oxygen consumption: which method is better? Thrush DN Crit Care Med; 1996 Jan; 24(1):91-5. PubMed ID: 8565545 [TBL] [Abstract][Full Text] [Related]
2. Continuous thermodilution cardiac output: agreement with Fick and bolus thermodilution methods. Thrush D; Downs JB; Smith RA J Cardiothorac Vasc Anesth; 1995 Aug; 9(4):399-404. PubMed ID: 7579109 [TBL] [Abstract][Full Text] [Related]
3. Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery. Chang AC; Kulik TJ; Hickey PR; Wessel DL Crit Care Med; 1993 Sep; 21(9):1369-75. PubMed ID: 8370302 [TBL] [Abstract][Full Text] [Related]
4. Oxygen consumption calculated from the Fick equation has limited utility. Stock MC; Ryan ME Crit Care Med; 1996 Jan; 24(1):86-90. PubMed ID: 8565544 [TBL] [Abstract][Full Text] [Related]
5. Oxygen Fick and modified carbon dioxide Fick cardiac outputs. Mahutte CK; Jaffe MB; Chen PA; Sasse SA; Wong DH; Sassoon CS Crit Care Med; 1994 Jan; 22(1):86-95. PubMed ID: 8124981 [TBL] [Abstract][Full Text] [Related]
6. Comparison of oxygen consumption measurements: indirect calorimetry versus the reversed Fick method. Smithies MN; Royston B; Makita K; Konieczko K; Nunn JF Crit Care Med; 1991 Nov; 19(11):1401-6. PubMed ID: 1935161 [TBL] [Abstract][Full Text] [Related]
7. Cardiac output from carbon dioxide production and arterial and venous oximetry. Mahutte CK; Jaffe MB; Sassoon CS; Wong DH Crit Care Med; 1991 Oct; 19(10):1270-7. PubMed ID: 1914484 [TBL] [Abstract][Full Text] [Related]
8. Lack of agreement between thermodilution and fick cardiac output in critically ill patients. Dhingra VK; Fenwick JC; Walley KR; Chittock DR; Ronco JJ Chest; 2002 Sep; 122(3):990-7. PubMed ID: 12226045 [TBL] [Abstract][Full Text] [Related]
9. Validation of cardiac output using real-time measurement of oxygen consumption during cardiac catheterization in children under 3 years of age. Seckeler MD; Hirsch R; Beekman RH; Goldstein BH Congenit Heart Dis; 2014; 9(4):307-15. PubMed ID: 24102795 [TBL] [Abstract][Full Text] [Related]
10. Comparison between cardiac output measured by thermodilution technique and calculated by O2 and modified CO2 Fick methods using a new metabolic monitor. Brandi LS; Bertolini R; Pieri M; Giunta F; Calafà M Intensive Care Med; 1997 Aug; 23(8):908-15. PubMed ID: 9310812 [TBL] [Abstract][Full Text] [Related]
11. Comparison between measured and fick-derived values of hemodynamic and oxymetric variables in patients with acute myocardial infarction. Pomés Iparraguirre H; Giniger R; Garber VA; Quiroga E; Jorge MA Am J Med; 1988 Sep; 85(3):349-52. PubMed ID: 3414730 [TBL] [Abstract][Full Text] [Related]
12. A comparison between the Fick method and indirect calorimetry for determining oxygen consumption in patients with fulminant hepatic failure. Walsh TS; Hopton P; Lee A Crit Care Med; 1998 Jul; 26(7):1200-7. PubMed ID: 9671369 [TBL] [Abstract][Full Text] [Related]
13. Calculated versus measured oxygen consumption during and after cardiac surgery. Is it possible to estimate lung oxygen consumption? Keinänen O; Takala J Acta Anaesthesiol Scand; 1997 Aug; 41(7):803-9. PubMed ID: 9265920 [TBL] [Abstract][Full Text] [Related]
14. Comparison of Accuracy of Estimation of Cardiac Output by Thermodilution Versus the Fick Method Using Measured Oxygen Uptake. Narang N; Thibodeau JT; Parker WF; Grodin JL; Garg S; Tedford RJ; Levine BD; McGuire DK; Drazner MH Am J Cardiol; 2022 Aug; 176():58-65. PubMed ID: 35613956 [TBL] [Abstract][Full Text] [Related]
15. Continuous measurement of cardiac output by the Fick principle in infants and children: comparison with the thermodilution method. Wippermann CF; Huth RG; Schmidt FX; Thul J; Betancor M; Schranz D Intensive Care Med; 1996 May; 22(5):467-71. PubMed ID: 8796404 [TBL] [Abstract][Full Text] [Related]
16. Oxygen consumption after cardiopulmonary bypass--implications of different measuring methods. Oudemans-van Straaten HM; Scheffer GJ; Eysman L; Wildevuur CR Intensive Care Med; 1993; 19(2):105-10. PubMed ID: 8486864 [TBL] [Abstract][Full Text] [Related]
17. Validation of cardiac output measurements with noninvasive Doppler echocardiography by thermodilution and Fick methods in newborn piglets. Welch E; Duara S; Suguihara C; Bandstra E; Bancalari E Biol Neonate; 1994; 66(2-3):137-45. PubMed ID: 7993947 [TBL] [Abstract][Full Text] [Related]
18. [Oxygen consumption by indirect calorimetry and Fick equation in swine: role of cardiac output]. Ozier Y; Grosse H; Baudin F; Urbani L; Gomola A; Conseiller C; Cardoso J Ann Fr Anesth Reanim; 1997; 16(2):131-7. PubMed ID: 9686074 [TBL] [Abstract][Full Text] [Related]
19. Continuous measurement of cardiac output by the Fick principle: clinical validation in intensive care. Keinänen O; Takala J; Kari A Crit Care Med; 1992 Mar; 20(3):360-5. PubMed ID: 1541096 [TBL] [Abstract][Full Text] [Related]
20. Cardiac output determination in children: equivalence of the transpulmonary thermodilution method to the direct Fick principle. Pauli C; Fakler U; Genz T; Hennig M; Lorenz HP; Hess J Intensive Care Med; 2002 Jul; 28(7):947-52. PubMed ID: 12122535 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]