These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
142 related articles for article (PubMed ID: 8565545)
21. Measuring cardiac output in critically Ill patients: disagreement between thermodilution-, calculated-, expired gas-, and oxygen consumption-based methods. Sherman MS; Kosinski R; Paz HL; Campbell D Cardiology; 1997; 88(1):19-25. PubMed ID: 8960620 [TBL] [Abstract][Full Text] [Related]
22. Effect of measurement errors on cardiac output calculated with O2 and modified CO2 Fick methods. Mahutte CK; Jaffe MB J Clin Monit; 1995 Mar; 11(2):99-108. PubMed ID: 7760094 [TBL] [Abstract][Full Text] [Related]
23. Oxygen consumption, energy expenditure, and substrate utilization after cardiac surgery in children. Gebara BM; Gelmini M; Sarnaik A Crit Care Med; 1992 Nov; 20(11):1550-4. PubMed ID: 1424698 [TBL] [Abstract][Full Text] [Related]
24. Comparison of a modified Fick method with thermodilution for determining cardiac output in critically ill patients on mechanical ventilation. Lynch J; Kaemmerer H Intensive Care Med; 1990; 16(4):248-51. PubMed ID: 2358558 [TBL] [Abstract][Full Text] [Related]
25. Continual trending of Fick variables in the critically ill patient. Quinn TJ; Weissman C; Kemper M Chest; 1991 Mar; 99(3):703-7. PubMed ID: 1899824 [TBL] [Abstract][Full Text] [Related]
26. Continuous Fick cardiac output measurement during exercise by monitoring of mixed venous oxygen saturation and oxygen uptake. Nakanishi N; Yoshioka T; Okano Y; Nishimura T Chest; 1993 Aug; 104(2):419-26. PubMed ID: 8339630 [TBL] [Abstract][Full Text] [Related]
27. Continuous measurement of oxygen consumption using the reversed fick method. Fukui M; Imoto M; Shime N; Hatanaka T; Tojo H J Anesth; 1997 Mar; 11(1):27-31. PubMed ID: 28921266 [TBL] [Abstract][Full Text] [Related]
28. Evaluation of oxygen uptake and delivery in critically ill patients: a statistical reappraisal. Hanique G; Dugernier T; Laterre PF; Roeseler J; Dougnac A; Reynaert MS Intensive Care Med; 1994; 20(1):19-26. PubMed ID: 8163753 [TBL] [Abstract][Full Text] [Related]
29. Comparison of cardiac output determined by bioimpedance, thermodilution, and the Fick method. Engoren M; Barbee D Am J Crit Care; 2005 Jan; 14(1):40-5. PubMed ID: 15608107 [TBL] [Abstract][Full Text] [Related]
30. Comparison of cardiac output measurements by arterial trans-cardiopulmonary and pulmonary arterial thermodilution with direct Fick in septic shock. Marx G; Schuerholz T; Sümpelmann R; Simon T; Leuwer M Eur J Anaesthesiol; 2005 Feb; 22(2):129-34. PubMed ID: 15816592 [TBL] [Abstract][Full Text] [Related]
31. [Comparison of 2 modified Fick methods and thermodilution for determining the cardiac output in patients with mechanical ventilation]. Corbanese U; Possamai C Minerva Anestesiol; 1995 May; 61(5):191-9. PubMed ID: 7478050 [TBL] [Abstract][Full Text] [Related]
32. [Continuous Fick cardiac output measurement during inhalation anesthesia]. Sato K Hokkaido Igaku Zasshi; 1992 Mar; 67(2):161-73. PubMed ID: 1597299 [TBL] [Abstract][Full Text] [Related]
33. Comparison of oxygen consumption calculated by Fick's principle (using a central venous catheter) and measured by indirect calorimetry. Inadomi C; Terao Y; Yamashita K; Fukusaki M; Takada M; Sumikawa K J Anesth; 2008; 22(2):163-6. PubMed ID: 18500614 [TBL] [Abstract][Full Text] [Related]
34. A practical method of measuring oxygen consumption in children with complex mixing circulations by the use of thermodilution cardiac output studies. Schantz DI; Chen RP J Thorac Cardiovasc Surg; 2013 Nov; 146(5):1179-84. PubMed ID: 23380516 [TBL] [Abstract][Full Text] [Related]
35. Calculated and measured oxygen consumption in mechanically ventilated surgical patients in the early post-operative period. Brandi LS; Bertolini R; Santini L Eur J Anaesthesiol; 1999 Jan; 16(1):53-61. PubMed ID: 10084102 [TBL] [Abstract][Full Text] [Related]
36. Ventilation/perfusion indices do not correlate with the difference between oxygen consumption measured by the Fick principle and metabolic monitoring systems in critically ill patients. Myburgh JA; Webb RK; Worthley LI Crit Care Med; 1992 Apr; 20(4):479-82. PubMed ID: 1559360 [TBL] [Abstract][Full Text] [Related]
37. [Inverse fick's principle in comparison to measurements of oxygen consumption in respiratory gases. Does intrapulmonary oxygen uptake account for differences shown by different system methods?]. Weyland A; Weyland W; Sydow M; Weyland C; Kettler D Anaesthesist; 1994 Oct; 43(10):658-66. PubMed ID: 7818047 [TBL] [Abstract][Full Text] [Related]
38. Energy expenditure and gas exchange measurements in postoperative patients: thermodilution versus indirect calorimetry. Brandi LS; Grana M; Mazzanti T; Giunta F; Natali A; Ferrannini E Crit Care Med; 1992 Sep; 20(9):1273-83. PubMed ID: 1521442 [TBL] [Abstract][Full Text] [Related]
39. Measurement of Oxygen Consumption Variations in Critically Ill Burns Patients: Are the Fick Method and Indirect Calorimetry Interchangeable? Soussi S; Vallée F; Roquet F; Bevilacqua V; Benyamina M; Ferry A; Cupaciu A; Chaussard M; De Tymowski C; Boccara D; Mimoun M; Chaouat M; Anstey J; Mebazaa A; Legrand M; Shock; 2017 Nov; 48(5):532-538. PubMed ID: 28452908 [TBL] [Abstract][Full Text] [Related]
40. Measured Oxygen Consumption During Pediatric Cardiac Catheterization is More Accurate than Assumed Oxygen Consumption. Ralston BH; Waberski AT; Kanter JP; Schick JW; Downing TE Pediatr Cardiol; 2024 Oct; 45(7):1466-1474. PubMed ID: 37243747 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]