BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 8573909)

  • 1. Ventricular pressure slope and bileaflet mechanical heart valve closure.
    Wu ZJ; Hwang NH
    ASAIO J; 1995; 41(3):M763-7. PubMed ID: 8573909
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Asynchronous closure and leaflet impact velocity of bileaflet mechanical heart valves.
    Wu ZJ; Hwang NH
    J Heart Valve Dis; 1995 Jul; 4 Suppl 1():S38-49. PubMed ID: 8581210
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The closing velocity of mechanical heart valve leaflets.
    Guo GX; Chiang TH; Quijano RC; Hwang NH
    Med Eng Phys; 1994 Nov; 16(6):458-64. PubMed ID: 7858776
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Occluder closing behavior: a key factor in mechanical heart valve cavitation.
    Wu ZJ; Wang Y; Hwang NH
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S25-33; discussion S33-4. PubMed ID: 8061868
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The closing velocity of Baxter Duromedic heart valve prostheses.
    Guo GX; Xu CC; Hwang NH
    ASAIO Trans; 1990; 36(3):M529-32. PubMed ID: 2252742
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of left ventricular dP/dt on the in vitro dynamics of the Björk-Shiley Convexo-Concave mitral valve.
    Rau G; Reul H; Eichler M; Schreck S; Wieting DW
    J Heart Valve Dis; 1995 Jul; 4 Suppl 1():S17-20. PubMed ID: 8581205
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dynamic impact stress analysis of a bileaflet mechanical heart valve.
    Yuan Q; Xu L; Ngoi BK; Yeo TJ; Hwang NH
    J Heart Valve Dis; 2003 Jan; 12(1):102-9. PubMed ID: 12578344
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Laser assessment of leaflet closing motion in prosthetic heart valves.
    Guo GX; Xu CC; Hwang NH
    J Biomed Eng; 1990 Nov; 12(6):477-81. PubMed ID: 2266743
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of structural compliance on cavitation threshold measurement of mechanical heart valves.
    Guo GX; Adlparvar P; Howanec M; Roy J; Kafesjian R; Kingsbury C
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S77-83; discussion S83-4. PubMed ID: 8061872
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Closing behavior of a new bileaflet mechanical heart valve.
    Bluestein D; Menon S; Wu ZJ; Haubold A; Armitage TL; Hwang NH
    ASAIO J; 1993; 39(3):M398-402. PubMed ID: 8268566
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hydrodynamic characteristics of bileaflet mechanical heart valves in an artificial heart: cavitation and closing velocity.
    Lee H; Homma A; Taenaka Y
    Artif Organs; 2007 Jul; 31(7):532-7. PubMed ID: 17584477
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vitro hydrodynamic characteristics among three bileaflet valves in the mitral position.
    Feng Z; Umezu M; Fujimoto T; Tsukahara T; Nurishi M; Kawaguchi D
    Artif Organs; 2000 May; 24(5):346-54. PubMed ID: 10848675
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mechanical valve closing dynamics: relationship between velocity of closing, pressure transients, and cavitation initiation.
    Chandran KB; Aluri S
    Ann Biomed Eng; 1997; 25(6):926-38. PubMed ID: 9395039
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The closing behavior of Medtronic Hall mechanical heart valves.
    Wu ZJ; Shu MC; Scott DR; Hwang NH
    ASAIO J; 1994; 40(3):M702-6. PubMed ID: 8555605
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Particle image velocimetry investigation of intravalvular flow fields of a bileaflet mechanical heart valve in a pulsatile flow.
    Subramanian A; Mu H; Kadambi JR; Wernet MP; Brendzel AM; Harasaki H
    J Heart Valve Dis; 2000 Sep; 9(5):721-31. PubMed ID: 11041190
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microflow fields in the hinge region of the CarboMedics bileaflet mechanical heart valve design.
    Leo HL; He Z; Ellis JT; Yoganathan AP
    J Thorac Cardiovasc Surg; 2002 Sep; 124(3):561-74. PubMed ID: 12202873
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Velocity of closure of Björk-Shiley Convexo-Concave mitral valves: effect of mitral annulus orientation and rate of left ventricular pressure rise.
    Blick EF; Wieting DW; Inderbitzen R; Schreck S; Stein PD
    J Heart Valve Dis; 1995 Jul; 4 Suppl 1():S26-30; discussion S30-1. PubMed ID: 8581208
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Noninvasive assessment of left ventricular function from the mitral valve echogram. Relation of final anterior mitral leaflet closing velocity to peak dp/dt and aortic velocity.
    Jugdutt BI; Lee SJ; McFarlane D
    Circulation; 1978 Nov; 58(5):861-71. PubMed ID: 699251
    [TBL] [Abstract][Full Text] [Related]  

  • 19. In vitro comparison of bileaflet aortic heart valve prostheses. St. Jude Medical, CarboMedics, modified Edwards-Duromedics, and Sorin-Bicarbon valves.
    Reul H; van Son JA; Steinseifer U; Schmitz B; Schmidt A; Schmitz C; Rau G
    J Thorac Cardiovasc Surg; 1993 Sep; 106(3):412-20. PubMed ID: 8361181
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Are the Current Doppler Echocardiography Criteria Able to Discriminate Mitral Bileaflet Mechanical Heart Valve Malfunction? An In Vitro Study.
    Evin M; Guivier-Curien C; Pibarot P; Kadem L; Rieu R
    Artif Organs; 2016 May; 40(5):E52-60. PubMed ID: 26813110
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.