These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 8573909)

  • 21. Mechanical heart valve cavitation in patients with bileaflet valves.
    Johansen P; Andersen TS; Hasenkam JM; Nygaard H; Paulsen PK
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():5655-8. PubMed ID: 25571278
    [TBL] [Abstract][Full Text] [Related]  

  • 22. An in vitro assessment by means of laser Doppler velocimetry of the medtronic advantage bileaflet mechanical heart valve hinge flow.
    Saxena R; Lemmon J; Ellis J; Yoganathan A
    J Thorac Cardiovasc Surg; 2003 Jul; 126(1):90-8. PubMed ID: 12878943
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Fluid dynamics of the CarboMedics kinetic bileaflet prosthetic heart valve.
    Baldwin JT; Campbell A; Luck C; Ogilvie W; Sauter J
    Eur J Cardiothorac Surg; 1997 Feb; 11(2):287-92. PubMed ID: 9080157
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Numerical simulation of mechanical mitral heart valve closure.
    Aluri S; Chandran KB
    Ann Biomed Eng; 2001 Aug; 29(8):665-76. PubMed ID: 11556723
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Transient pressure signals in mechanical heart valve cavitation.
    Wu ZJ; Slonin JH; Hwang NH
    ASAIO J; 1996; 42(5):M555-61. PubMed ID: 8944941
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Preliminary study on the new self-closing mechanical mitral valve.
    Naemura K; Umezu M; Dohi T
    Artif Organs; 1999 Sep; 23(9):869-75. PubMed ID: 10491036
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Noise levels of closing sounds in vivo are equal for different bileaflet mechanical heart valves.
    Johansen P; Hansen SB; Hasenkam JM; Nygaard H
    J Heart Valve Dis; 2003 Nov; 12(6):764-71. PubMed ID: 14658819
    [TBL] [Abstract][Full Text] [Related]  

  • 28. In vitro observations of mechanical heart valve cavitation.
    Shu MC; Leuer LH; Armitage TL; Schneider TE; Christiansen DR
    J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S85-92; discussion S92-3. PubMed ID: 8061874
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Estimation of mechanical heart valve cavitation in a pneumatic ventricular assist device.
    Lee H; Akagawa E; Homma A; Tsukiya T; Tatsumi E; Taenaka Y
    J Artif Organs; 2007; 10(3):181-5. PubMed ID: 17846718
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Noninvasive estimation of the instantaneous first derivative of left ventricular pressure using continuous-wave Doppler echocardiography.
    Chen C; Rodriguez L; Guerrero JL; Marshall S; Levine RA; Weyman AE; Thomas JD
    Circulation; 1991 Jun; 83(6):2101-10. PubMed ID: 2040059
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Hydrodynamic function of tilting disc prostheses and bileaflet valves in double valve replacement.
    StrĂ¼ber M; Campbell A; Richard G; Laas J
    Eur J Cardiothorac Surg; 1996; 10(6):422-7. PubMed ID: 8817137
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The orientation of the bi-leaflet CarboMedics valve in the mitral position determines left ventricular spatial flow patterns.
    Van Rijk-Zwikker GL; Delemarre BJ; Huysmans HA
    Eur J Cardiothorac Surg; 1996; 10(7):513-20. PubMed ID: 8855422
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesis.
    Bluestein D; Einav S; Hwang NH
    J Biomech; 1994 Nov; 27(11):1369-78. PubMed ID: 7798287
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effect of heart rate on the hemodynamics of bileaflet mechanical heart valves' prostheses (St. Jude Medical) in the aortic position and in the opening phase: A computational study.
    Jahandardoost M; Fradet G; Mohammadi H
    Proc Inst Mech Eng H; 2016 Mar; 230(3):175-90. PubMed ID: 26786673
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Transient pressure at closing of a monoleaflet mechanical heart valve prosthesis: mounting compliance effect.
    Wu ZJ; Gao BZ; Hwang NH
    J Heart Valve Dis; 1995 Sep; 4(5):553-67. PubMed ID: 8581200
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Dynamic particle image velocimetry flow analysis of the flow field immediately downstream of bileaflet mechanical mitral prostheses.
    Akutsu T; Saito J
    J Artif Organs; 2006; 9(3):165-78. PubMed ID: 16998702
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Vortex shedding in bileaflet heart valve prostheses.
    Gross JM; Shermer CD; Hwang NH
    ASAIO Trans; 1988; 34(3):845-50. PubMed ID: 3196609
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Direct imaging of bileaflet mechanical valve behavior in the tricuspid position.
    Ikeda K; Okazaki Y; Furukawa K; Ohtsubo S; Yunoki J; Natsuaki M; Itoh T
    Eur J Cardiothorac Surg; 2006 Jun; 29(6):1014-9. PubMed ID: 16675254
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Bileaflet mechanical heart valves at low cardiac output.
    Wu ZJ; Gao BZ; Slonin JH; Hwang NH
    ASAIO J; 1996; 42(5):M747-9. PubMed ID: 8944981
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Lumped parameter model for computing the minimum pressure during mechanical heart valve closure.
    Maines BH; Brennen CE
    J Biomech Eng; 2005 Aug; 127(4):648-55. PubMed ID: 16121535
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.