These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 8575475)

  • 1. Changes in cerebral blood flow induced by balloon test occlusion of the internal carotid artery under hypotension.
    Tanaka F; Nishizawa S; Yonekura Y; Sadato N; Ishizu K; Okazawa H; Tamaki N; Nakahara I; Taki W; Konishi J
    Eur J Nucl Med; 1995 Nov; 22(11):1268-73. PubMed ID: 8575475
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A provocative internal carotid artery balloon occlusion test with 99mTc-HM-PAO CBF mapping--report of three cases.
    Komiyama M; Khosla VK; Tamura K; Nagata Y; Baba M
    Neurol Med Chir (Tokyo); 1992 Sep; 32(10):747-52. PubMed ID: 1280776
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Failure of the hypotensive provocative test during temporary balloon test occlusion of the internal carotid artery to predict delayed hemodynamic ischemia after therapeutic carotid occlusion.
    Dare AO; Chaloupka JC; Putman CM; Fayad PB; Awad IA
    Surg Neurol; 1998 Aug; 50(2):147-55; discussion 155-6. PubMed ID: 9701120
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Multimodal carotid occlusion test for determining risk of infarct before therapeutic internal carotid artery occlusion].
    Keller E; Ries F; Grünwald F; Honisch C; Rosanowski F; Pavics L; Herberhold C; Solymosi L
    Laryngorhinootologie; 1995 May; 74(5):307-11. PubMed ID: 7605571
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Efficacy of the stump pressure ratio as a guide to the safety of permanent occlusion of the internal carotid artery.
    Morishima H; Kurata A; Miyasaka Y; Fujii K; Kan S
    Neurol Res; 1998 Dec; 20(8):732-6. PubMed ID: 9864739
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cerebral blood flow and metabolism measurement using positron emission tomography before and during internal carotid artery test occlusions: feasibility of rapid quantitative measurement of CBF and OEF/CMRO(2).
    Kawai N; Kawanishi M; Shindou A; Kudomi N; Yamamoto Y; Nishiyama Y; Tamiya T
    Interv Neuroradiol; 2012 Sep; 18(3):264-74. PubMed ID: 22958764
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Carotid artery balloon test occlusion: combined clinical evaluation and xenon-enhanced computed tomographic cerebral blood flow evaluation without patient transfer or balloon reinflation: technical note.
    Barr JD; Lemley TJ; McCann RM
    Neurosurgery; 1998 Sep; 43(3):634-7; discussion 637-8. PubMed ID: 9733323
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cerebral blood flow response pattern during balloon test occlusion of the internal carotid artery.
    Witt JP; Yonas H; Jungreis C
    AJNR Am J Neuroradiol; 1994 May; 15(5):847-56. PubMed ID: 8059651
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Parent artery occlusion with bypass surgery for the treatment of internal carotid artery aneurysms: clinical and hemodynamic results.
    Shimizu H; Matsumoto Y; Tominaga T
    Clin Neurol Neurosurg; 2010 Jan; 112(1):32-9. PubMed ID: 19875229
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Crossed cerebellar diaschisis associated with balloon test occlusion of the carotid artery.
    Nathan MA; Bushnell DL; Kahn D; Simonson TM; Kirchner PT
    Nucl Med Commun; 1994 Jun; 15(6):448-54. PubMed ID: 8078641
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Balloon test occlusion of the internal carotid artery with stable xenon/CT cerebral blood flow imaging.
    Erba SM; Horton JA; Latchaw RE; Yonas H; Sekhar L; Schramm V; Pentheny S
    AJNR Am J Neuroradiol; 1988; 9(3):533-8. PubMed ID: 3132827
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Preliminary results of Tc-99m ECD SPECT to evaluate cerebral collateral circulation during balloon test occlusion.
    Yamamoto Y; Nishiyama Y; Toyama Y; Satoh K; Irie K; Ohkawa M
    Clin Nucl Med; 2002 Sep; 27(9):633-7. PubMed ID: 12192280
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Balloon test occlusion of the internal carotid artery with hypotensive challenge.
    Standard SC; Ahuja A; Guterman LR; Chavis TD; Gibbons KJ; Barth AP; Hopkins LN
    AJNR Am J Neuroradiol; 1995 Aug; 16(7):1453-8. PubMed ID: 7484632
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Treatment strategies for complex internal carotid artery (ICA) aneurysms: direct ICA sacrifice or combined with extracranial-to-intracranial bypass.
    Zhu W; Tian YL; Zhou LF; Song DL; Xu B; Mao Y
    World Neurosurg; 2011; 75(3-4):476-84. PubMed ID: 21600500
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Characterization of the cerebral blood flow response to balloon deflation after temporary internal carotid artery test occlusion.
    Gupta DK; Young WL; Hashimoto T; Halim AX; Marshall RS; Lazar RM; Joshi S; Pile-Spellman J; Ostapkovich N
    J Neurosurg Anesthesiol; 2002 Apr; 14(2):123-9. PubMed ID: 11907392
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical utility of quantitative cerebral blood flow measurements during internal carotid artery test occlusions.
    Marshall RS; Lazar RM; Young WL; Solomon RA; Joshi S; Duong DH; Rundek T; Pile-Spellman J
    Neurosurgery; 2002 May; 50(5):996-1004; discussion 1004-5. PubMed ID: 11950402
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reversal of severe SPECT asymmetry after venous extra-intracranial high flow bypass in a patient submitted to therapeutic internal carotid occlusion: case report.
    Marcondes J; Aversa A; Peçanha M; Domingues F; Nascimento F; André C; Freitas G; Azevedo F; Exposito M
    Arq Neuropsiquiatr; 2001 Sep; 59(3-B):797-801. PubMed ID: 11593286
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ischemic Tolerance Evaluated by Computed Tomography Perfusion during Balloon Test Occlusion.
    Kuribara T; Mikami T; Iihoshi S; Miyata K; Kim S; Kawata Y; Komatsu K; Kimura Y; Enatsu R; Akiyama Y; Hirano T; Mikuni N
    J Stroke Cerebrovasc Dis; 2020 Jun; 29(6):104807. PubMed ID: 32295733
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [15O]H2O positron emission tomography determination of cerebral blood flow during balloon test occlusion of the internal carotid artery.
    Brunberg JA; Frey KA; Horton JA; Deveikis JP; Ross DA; Koeppe RA
    AJNR Am J Neuroradiol; 1994 Apr; 15(4):725-32. PubMed ID: 8010276
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Brain perfusion imaging during preoperative temporary balloon occlusion of the internal carotid artery.
    Lorberboym M; Pandit N; Machac J; Holan V; Sacher M; Segal D; Sen C
    J Nucl Med; 1996 Mar; 37(3):415-9. PubMed ID: 8772634
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.