These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

435 related articles for article (PubMed ID: 8578358)

  • 41. Temperature measurement: comparison of non-invasive methods used in adult critical care.
    Farnell S; Maxwell L; Tan S; Rhodes A; Philips B
    J Clin Nurs; 2005 May; 14(5):632-9. PubMed ID: 15840078
    [TBL] [Abstract][Full Text] [Related]  

  • 42. A comparative study of rectal tympanic and axillary thermometry in febrile children under 5 years of age in Nigeria.
    Abdulkadir MB; Johnson 'B
    Paediatr Int Child Health; 2013 Aug; 33(3):165-9. PubMed ID: 23930729
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Lack of agreement between tympanic and oral temperature measurements in adult hospitalized patients.
    Manian FA; Griesenauer S
    Am J Infect Control; 1998 Aug; 26(4):428-30. PubMed ID: 9721397
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Measuring the accuracy of the infrared tympanic thermometer: correlation does not signify agreement.
    Yaron M; Lowenstein SR; Koziol-McLain J
    J Emerg Med; 1995; 13(5):617-21. PubMed ID: 8530778
    [TBL] [Abstract][Full Text] [Related]  

  • 45. NexTemp thermometer can be used interchangeably with tympanic or mercury thermometers for emergency department use.
    Rajee M; Sultana RV
    Emerg Med Australas; 2006 Jun; 18(3):245-51. PubMed ID: 16712534
    [TBL] [Abstract][Full Text] [Related]  

  • 46. The performance of two tympanic thermometers in a pediatric emergency department.
    Terndrup TE; Milewski A
    Clin Pediatr (Phila); 1991 Apr; 30(4 Suppl):18-23; discussion 34-5. PubMed ID: 2029813
    [TBL] [Abstract][Full Text] [Related]  

  • 47. [Comparison of different methods of temperature measurment in children].
    Pavlović M; Radlović N; Leković Z; Berenji K
    Med Pregl; 2008; 61(11-12):615-9. PubMed ID: 19368282
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Are all thermometers equal? A study of three infrared thermometers to detect fever in an African outpatient clinic.
    Ravi N; Vithyananthan M; Saidu A
    PeerJ; 2022; 10():e13283. PubMed ID: 35726256
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Effect of otitis media on infrared tympanic thermometry.
    Kelly B; Alexander D
    Clin Pediatr (Phila); 1991 Apr; 30(4 Suppl):46-8; discussion 49. PubMed ID: 2029819
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Comparison of oral and tympanic temperatures in adult surgical patients.
    Gilbert M; Barton AJ; Counsell CM
    Appl Nurs Res; 2002 Feb; 15(1):42-7. PubMed ID: 11840409
    [TBL] [Abstract][Full Text] [Related]  

  • 51. A comparative study on accuracy of liquid crystal forehead, digital electronic axillary, infrared tympanic with glass-mercury rectal thermometer in infants and young children.
    Kongpanichkul A; Bunjongpak S
    J Med Assoc Thai; 2000 Sep; 83(9):1068-76. PubMed ID: 11075975
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Tympanic membrane temperatures compared to rectal and oral temperatures.
    Talo H; Macknin ML; Medendorp SV
    Clin Pediatr (Phila); 1991 Apr; 30(4 Suppl):30-3; discussion 34-5. PubMed ID: 2029816
    [TBL] [Abstract][Full Text] [Related]  

  • 53. [Electronic rectal temperature measurement. A clinical trial].
    Ottesen S; Nielsen FT; Lund H
    Ugeskr Laeger; 1993 May; 155(21):1642-4. PubMed ID: 8317002
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Comparison of tympanic and rectal temperature in febrile patients.
    Sehgal A; Dubey NK; Jyothi MC; Jain S
    Indian J Pediatr; 2002 Apr; 69(4):305-8. PubMed ID: 12019550
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Ear measurement of temperature is only useful for screening for fever in an adult emergency department.
    Mogensen CB; Vilhelmsen MB; Jepsen J; Boye LK; Persson MH; Skyum F
    BMC Emerg Med; 2018 Dec; 18(1):51. PubMed ID: 30509206
    [TBL] [Abstract][Full Text] [Related]  

  • 56. [What alternatives to rectal temperature recording with a mercury thermometer?].
    Pazart L; Devilliers E; Bouté C; Aho S; Rupin C; Gouyon JB
    Rev Epidemiol Sante Publique; 1997 Dec; 45(6):516-26. PubMed ID: 9496582
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Accuracy and feasibility of daily infrared tympanic membrane temperature measurements in the identification of fever in children.
    van Staaij BK; Rovers MM; Schilder AG; Hoes AW
    Int J Pediatr Otorhinolaryngol; 2003 Oct; 67(10):1091-7. PubMed ID: 14550963
    [TBL] [Abstract][Full Text] [Related]  

  • 58. A comparison of infrared ear thermometry with electronic predictive thermometry in a geriatric setting.
    Prentice D; Moreland J
    Geriatr Nurs; 1999; 20(6):314-7. PubMed ID: 10601896
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Accuracy of tympanic temperature measurement using an infrared tympanic membrane thermometer.
    Gasim GI; Musa IR; Abdien MT; Adam I
    BMC Res Notes; 2013 May; 6():194. PubMed ID: 23663659
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Comparison of the temporal artery and rectal thermometry in children in the emergency department.
    Schuh S; Komar L; Stephens D; Chu L; Read S; Allen U
    Pediatr Emerg Care; 2004 Nov; 20(11):736-41. PubMed ID: 15502654
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 22.