These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

373 related articles for article (PubMed ID: 8578793)

  • 21. Clinical and technical determinants of long-term performance of coronary sinus leads.
    La Rocca V; Bertaglia E; Solimene F; Accogli M; Iuliano A; Marrazzo N; De Luca De Masi G; Scaccia A; Donnici G; Chiariello P; Turco P; De Simone A; Ciardiello C; Stabile G
    J Cardiovasc Med (Hagerstown); 2010 Jan; 11(1):40-4. PubMed ID: 19770774
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Comparative studies of thresholds after implantation of pacemaker leads of different size (author's transl)].
    Kleinert M; Irnich W; Beer P
    Z Kardiol; 1977 Apr; 66(4):191-7. PubMed ID: 857458
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Worldwide evaluation of a defibrillation lead with a small geometric electrode surface for high-impedance pacing.
    Vollmann D; Ahern T; Gerritse B; Canby RC; Zenker D; Binner L; Kimber SK; Unterberg C;
    Am Heart J; 2003 Dec; 146(6):1066-70. PubMed ID: 14661000
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Electrical performance and automatic capture characteristics of a 3.5-mm(2) passive fixation lead during 1-year follow-up.
    Lotze U; Fischer S; Höfs T; Liebetrau J; Fettin W; Scheiner J; Lang A;
    Pacing Clin Electrophysiol; 2009 Aug; 32(8):1050-5. PubMed ID: 19659625
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Latest generation of unipolar and bipolar steroid eluting leads: long-term comparison of electrical performance in atrium and ventricles.
    Cornacchia D; Fabbri M; Puglisi A; Moracchini P; Bernasconi M; Nastasi M; Menozzi C; Mascioli G; Marotta T; de Seta F
    Europace; 2000 Jul; 2(3):240-4. PubMed ID: 11227595
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Experience in the use of a new endocardial stimulation electrode].
    Frangini P; Vergara I; González R; Baeza M; Cambón AM
    Rev Med Chil; 2006 Jun; 134(6):749-53. PubMed ID: 17130950
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Do steroid-eluting pacemaker electrodes permit programming at lower pacemaker pulse amplitudes?].
    Schuchert A; Kuck KH; Meinertz T
    Dtsch Med Wochenschr; 1995 Apr; 120(17):593-6. PubMed ID: 7736956
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Stable stimulation impedance of steroid electrodes in various impulse amplitudes: indications for low polarization of the electrode-myocardium interface].
    Schuchert A; Kuck KH
    Z Kardiol; 1993 Jan; 82(1):41-5. PubMed ID: 8470419
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Rapid decline in acute stimulation thresholds with steroid-eluting active-fixation pacing leads.
    Kistler PM; Kalman JM; Fynn SP; Singarayar S; Roberts-Thomson KC; Lindsay CB; Khong U; Sparks PB; Strathmore N; Mond HG
    Pacing Clin Electrophysiol; 2005 Sep; 28(9):903-9. PubMed ID: 16176527
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Comparison of electrical characteristics between a steroid-eluting single-pass VDD lead and a standard steroid-eluting ventricular lead. Thera Pacemaker Study Group.
    Schuchert A; Van Langen H; Michels K; Meinertz T
    Pacing Clin Electrophysiol; 1997 Jul; 20(7):1787-9. PubMed ID: 9249832
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Variation in the evoked ventricular potentials after the implantation of an endocardiac catheter; the correlation with stimulation thresholds].
    Azzarelli A; Paolini E; Masini M; Lazzari M; Mariani PR; Cortigiani L; Nannini E; Bernardi D
    G Ital Cardiol; 1999 Jun; 29(6):669-74. PubMed ID: 10396671
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Current of injury predicts adequate active lead fixation in permanent pacemaker/defibrillation leads.
    Saxonhouse SJ; Conti JB; Curtis AB
    J Am Coll Cardiol; 2005 Feb; 45(3):412-7. PubMed ID: 15680721
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A fractally coated, 1.3 mm2 high impedance pacing electrode.
    Fröhlig G; Bolz A; Ströbel J; Rutz M; Lawall P; Schwerdt H; Schaldach M; Schieffer H
    Pacing Clin Electrophysiol; 1998 Jun; 21(6):1239-46. PubMed ID: 9633066
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Present day pacemakers for pulse generator exchange: is 3.5 V a sufficient nominal setting for the pulse amplitude? Thera Pacemaker Study Group.
    Schuchert A; Van Langen H; Michels K; Meinertz T
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1824-7. PubMed ID: 8945049
    [TBL] [Abstract][Full Text] [Related]  

  • 35. ["QT" pacemaker in aggregate exchange. Do old electrodes impair functional ability?].
    Sigmund M; Schwindke P; Recker S; Johnen A; Hanrath P
    Z Kardiol; 1991 Mar; 80(3):194-200. PubMed ID: 2058250
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Sensing failure associated with the Medtronic Sprint Fidelis defibrillator lead.
    Kenigsberg DN; Mirchandani S; Dover AN; Kowalski M; Wood MA; Shepard RK; Kalahasty G; Stein KM; Markowitz SM; Iwai S; Shah BK; Lerman BB; Mittal S; Ellenbogen KA
    J Cardiovasc Electrophysiol; 2008 Mar; 19(3):270-4. PubMed ID: 18179527
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Clinical results of far-field R-wave reduction with a short tip-ring electrode.
    De Groot JR; Schroeder-Tanka JM; Visser J; Willems AR; De Voogt WG
    Pacing Clin Electrophysiol; 2008 Dec; 31(12):1554-9. PubMed ID: 19067807
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Far-field R-wave reduction with a novel lead design: experimental and human results.
    de Voogt W; van Hemel N; Willems A; Visser J; Chitre Y; Bornzin G; Helland J
    Pacing Clin Electrophysiol; 2005 Aug; 28(8):782-8. PubMed ID: 16105005
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Reasons and complications of pacemaker replacement operation: clinical analysis of 69 case-times].
    Liu XL; Ren LH; Ye HM
    Zhonghua Yi Xue Za Zhi; 2008 Jul; 88(28):1989-91. PubMed ID: 19062742
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Prerequisites for pacemaker electrodes for individual programming of a low stimulation impulse (comparison of an Elgiloy and a steroid-dependent pacemaker electrode)].
    Schuchert A; Kuck KH; Bleifeld W
    Z Kardiol; 1990 Jun; 79(6):403-7. PubMed ID: 2378158
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]