These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

197 related articles for article (PubMed ID: 8581207)

  • 1. Dynamics of Björk-Shiley Convexo-Concave mitral valves in sheep.
    Schreck S; Inderbitzen R; Chin H; Wieting DW; Smilor M; Breznock E; Pendray D
    J Heart Valve Dis; 1995 Jul; 4 Suppl 1():S21-4; discussion S24-5. PubMed ID: 8581207
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of left ventricular dP/dt on the in vitro dynamics of the Björk-Shiley Convexo-Concave mitral valve.
    Rau G; Reul H; Eichler M; Schreck S; Wieting DW
    J Heart Valve Dis; 1995 Jul; 4 Suppl 1():S17-20. PubMed ID: 8581205
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Velocity of closure of Björk-Shiley Convexo-Concave mitral valves: effect of mitral annulus orientation and rate of left ventricular pressure rise.
    Blick EF; Wieting DW; Inderbitzen R; Schreck S; Stein PD
    J Heart Valve Dis; 1995 Jul; 4 Suppl 1():S26-30; discussion S30-1. PubMed ID: 8581208
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pressure distribution near the occluders and impact forces on the outlet struts of Björk-Shiley convexo-concave valves during closing.
    Chandran KB; Lee CS; Aluri S; Dellsperger KC; Schreck S; Wieting DW
    J Heart Valve Dis; 1996 Mar; 5(2):199-206. PubMed ID: 8665015
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical performance of Bjork-Shiley mechanical heart valves: a perspective on outlet strut fractures in the 60 degrees and 70 degrees convexo-concave disc models.
    Scully HE; Damle A; Goldman BS; Tong C; Azuma J; Mickleborough LL; Schwartz L; Baird RJ
    Can J Cardiol; 1988 Oct; 4(7):386-92. PubMed ID: 3228767
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Manufacturing characteristics associated with strut fracture in Björk-Shiley 60 degrees Convexo-Concave heart valves.
    Walker AM; Funch DP; Sulsky SI; Dreyer NA
    J Heart Valve Dis; 1995 Nov; 4(6):640-8. PubMed ID: 8611980
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Three-dimensional imaging of fractures in outlet struts of Björk-Shiley convexo-concave heart valves by microcomputed tomography in vitro.
    Brendzel AM; Rambod E; Jorgensen SM; Reyes DA; Chmelik MS; Ritman EL
    J Heart Valve Dis; 2002 Jan; 11(1):114-20. PubMed ID: 11843496
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Strut fracture mechanisms of the Björk-Shiley convexo-concave heart valve.
    Wieting DW; Eberhardt AC; Reul H; Breznock EM; Schreck SG; Chandler JG
    J Heart Valve Dis; 1999 Mar; 8(2):206-17. PubMed ID: 10224582
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Which manufacturing characteristics are predictors of outlet strut fracture in large sixty-degree Björk-Shiley convexo-concave mitral valves? The Björk-Shiley Study Group.
    Kallewaard M; Algra A; Defauw J; van der Graaf Y
    J Thorac Cardiovasc Surg; 1999 Apr; 117(4):766-75. PubMed ID: 10096973
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Strut fracture of Björk-Shiley convexo-concave valve in Japan--risk of small valve size--.
    Watarida S; Shiraishi S; Nishi T; Imura M; Yamamoto Y; Hirokawa R; Fujita M
    Ann Thorac Cardiovasc Surg; 2001 Aug; 7(4):246-9. PubMed ID: 11578268
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanical failure of the Björk-Shiley valve. Incidence, clinical presentation, and management.
    Lindblom D; Björk VO; Semb BK
    J Thorac Cardiovasc Surg; 1986 Nov; 92(5):894-907. PubMed ID: 3773546
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Acoustic characterization of mechanical valve condition and loading.
    Eberhardt AC; Chassaing CE; Ward MA; Lewandowski SJ
    J Heart Valve Dis; 1995 Nov; 4(6):649-58; discussion 658-9. PubMed ID: 8611981
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Low frequency analysis of opening sound for detection of single leg separation of Björk-Shiley Convexo-Concave heart valves.
    Durand LG; Grenier MC; Inderbitzen R; Wieting DW; Stein PD
    J Heart Valve Dis; 1995 Jul; 4 Suppl 1():S32-7. PubMed ID: 8581209
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Outlet strut fracture of a 23-mm Björk-Shiley 70 degrees convexo-concave aortic valve.
    Abad C
    Cardiovasc Surg; 1993 Aug; 1(4):445-6. PubMed ID: 8076078
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Björk-Shiley 70 degree convexo-concave prosthesis strut fracture problem (present state of information).
    Ostermeyer J; Horstkotte D; Bennett J; Huysmans H; Lindblom D; Olin C; Orinius E; Semb G
    Thorac Cardiovasc Surg; 1987 Apr; 35(2):71-7. PubMed ID: 2440138
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Outlet strut fracture of Björk-Shiley convexo-concave valves: can valve-manufacturing characteristics explain the risk?
    Omar RZ; Morton LS; Beirne M; Blot WJ; Lawford PV; Hose R; Taylor KM
    J Thorac Cardiovasc Surg; 2001 Jun; 121(6):1143-9. PubMed ID: 11385382
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vivo accuracy of two radiographic systems in the detection of Björk-Shiley convexo-concave heart valve outlet strut single leg separations.
    Hopper KD; Gilchrist IC; Landis JR; Abolfathi AH; Localio AR; Wilson RP; Pae WE; Kunselman AR; Wieting DW; Griffith JW; Pierce WS; Potok PS; TenHave TR; Chandler JG
    J Thorac Cardiovasc Surg; 1998 Mar; 115(3):582-90. PubMed ID: 9535446
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Single leg separation prevalence among explanted Björk-Shiley prosthetic heart valves.
    Blot WJ; Signorello LB; Cohen SS; Ibrahim MA
    J Heart Valve Dis; 2007 Nov; 16(6):657-61. PubMed ID: 18095516
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of disc retention of Björk-Shiley Delrin heart valves.
    Thyagarajan K; Conlin CH; Wieting DW
    J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S243-5. PubMed ID: 8905525
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Strut fracture of a convex-concave 60 degree Björk-Shiley mitral valve prosthesis 5 years after implantation--metallurgic analysis of the prosthesis strut].
    Lemke B; Rathmann J; Wiebe V; Witzel U
    Z Kardiol; 1991 Aug; 80(8):537-40. PubMed ID: 1950077
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.