These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 8582723)

  • 1. Reduction of motion artifacts using a two-frequency impedance plethysmograph and adaptive filtering.
    Rosell J; Cohen KP; Webster JG
    IEEE Trans Biomed Eng; 1995 Oct; 42(10):1044-8. PubMed ID: 8582723
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Signal-to-motion artifact ratio versus frequency for impedance pneumography.
    Rosell J; Webster JG
    IEEE Trans Biomed Eng; 1995 Mar; 42(3):321-3. PubMed ID: 7698789
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of impedance and inductance ventilation sensors on adults during breathing, motion, and simulated airway obstruction.
    Cohen KP; Ladd WM; Beams DM; Sheers WS; Radwin RG; Tompkins WJ; Webster JG
    IEEE Trans Biomed Eng; 1997 Jul; 44(7):555-66. PubMed ID: 9210815
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimum electrode configuration for detection of leg movement using bio-impedance.
    Song CG; Kim SC; Nam KC; Kim DW
    Physiol Meas; 2005 Apr; 26(2):S59-68. PubMed ID: 15798247
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Study of the optimum level of electrode placement for the evaluation of absolute lung resistivity with the Mk3.5 EIT system.
    Nebuya S; Noshiro M; Yonemoto A; Tateno S; Brown BH; Smallwood RH; Milnes P
    Physiol Meas; 2006 May; 27(5):S129-37. PubMed ID: 16636404
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cardiorespiratory monitoring equipment interferes with whole body impedance measurements.
    Lingwood BE; Dunster KR; Ward LC
    Physiol Meas; 2005 Apr; 26(2):S235-40. PubMed ID: 15798236
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Imaging of conductivity changes and electrode movement in EIT.
    Soleimani M; Gómez-Laberge C; Adler A
    Physiol Meas; 2006 May; 27(5):S103-13. PubMed ID: 16636402
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impedance spectroscopy of changes in skin-electrode impedance induced by motion.
    Cömert A; Hyttinen J
    Biomed Eng Online; 2014 Nov; 13():149. PubMed ID: 25404355
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Electrocardiographic motion artifact versus electrode impedance.
    Wiese SR; Anheier P; Connemara RD; Mollner AT; Neils TF; Kahn JA; Webster JG
    IEEE Trans Biomed Eng; 2005 Jan; 52(1):136-9. PubMed ID: 15651575
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of human uterine cervical electrical impedance measurements derived using two tetrapolar probes of different sizes.
    Gandhi SV; Walker DC; Brown BH; Anumba DO
    Biomed Eng Online; 2006 Nov; 5():62. PubMed ID: 17125510
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measuring lower leg swelling: optimum frequency for impedance method.
    Seo A; Rys M; Konz S
    Med Biol Eng Comput; 2001 Mar; 39(2):185-9. PubMed ID: 11361245
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Significance of the electric current characteristics used in rheography. Study on the relationship between frequency, voltage and intensity of the current with reference to impedance values of the body mass].
    Fogari R; Bernardi L; Tumiati G
    Arch Sci Med (Torino); 1976; 133(3):217-22. PubMed ID: 1016556
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Adaptive and wavelet filtering methods for improving accuracy of respiratory measurement.
    Keenan DB; Wilhelm FH
    Biomed Sci Instrum; 2005; 41():37-42. PubMed ID: 15850079
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The electrode system in impedance-based ventilation measurement.
    Luo S; Afonso VX; Webster JG; Tompkins WJ
    IEEE Trans Biomed Eng; 1992 Nov; 39(11):1130-41. PubMed ID: 1487276
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparison of two- and four-electrode techniques to characterize blood impedance for the frequency range of 100 Hz to 100 MHz.
    Chang ZY; Pop GM; Meijer GM
    IEEE Trans Biomed Eng; 2008 Mar; 55(3):1247-9. PubMed ID: 18334424
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Design of an impedance plethysmograph for reactive hyperemia evaluation in the forearm].
    Parra JE; Mora F; Villegas G; Romero-Vecchione E; Vásquez J
    Acta Cient Venez; 2003; 54(1):2-11. PubMed ID: 14515761
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An advanced signal processing technique for impedance cardiography.
    Wang X; Sun HH; Van de Water JM
    IEEE Trans Biomed Eng; 1995 Feb; 42(2):224-30. PubMed ID: 7868150
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of power-line interference for adaptive motion artifact removal in biopotential measurements.
    Xu L; Rooijakkers MJ; Rabotti C; Peuscher J; Mischi M
    Physiol Meas; 2016 Jan; 37(1):25-40. PubMed ID: 26641265
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multi-frequency electrical impedance tomography (EIT) of the adult human head: initial findings in brain tumours, arteriovenous malformations and chronic stroke, development of an analysis method and calibration.
    Romsauerova A; McEwan A; Horesh L; Yerworth R; Bayford RH; Holder DS
    Physiol Meas; 2006 May; 27(5):S147-61. PubMed ID: 16636407
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Epsilon-tube filtering: reduction of high-amplitude motion artifacts from impedance plethysmography signal.
    Ansari S; Ward K; Najarian K
    IEEE J Biomed Health Inform; 2015 Mar; 19(2):406-17. PubMed ID: 24723634
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.