131 related articles for article (PubMed ID: 8582763)
1. Hemoscan: a dialysis machine-integrated blood volume monitor.
Paolini F; Mancini E; Bosetto A; Santoro A
Int J Artif Organs; 1995 Sep; 18(9):487-94. PubMed ID: 8582763
[TBL] [Abstract][Full Text] [Related]
2. Blood volume modeling and refilling rate estimation in hemodialysis by continuous hemoglobin monitoring.
Arrigo G; Bucci R; Colasanti G; Rustici A; Sivo M; Rizza V; D'Amico G
Int J Artif Organs; 1995 Sep; 18(9):509-12. PubMed ID: 8582767
[TBL] [Abstract][Full Text] [Related]
3. A non-invasive continuous method of measuring blood volume during haemodialysis using optical techniques.
McMahon MP; Campbell SB; Shannon GF; Wilkinson JS; Fleming SJ
Med Eng Phys; 1996 Mar; 18(2):105-9. PubMed ID: 8673315
[TBL] [Abstract][Full Text] [Related]
4. Relative blood volume measurements during hemodialysis: comparisons between three noninvasive devices.
Dasselaar JJ; Huisman RM; DE Jong PE; Franssen CF
Hemodial Int; 2007 Oct; 11(4):448-55. PubMed ID: 17922743
[TBL] [Abstract][Full Text] [Related]
5. Online measurement of haemoglobin concentration.
Chesterton L; Lambie SH; Hulme LJ; Taal M; Fluck RJ; McIntyre CW
Nephrol Dial Transplant; 2005 Sep; 20(9):1951-5. PubMed ID: 15998655
[TBL] [Abstract][Full Text] [Related]
6. Simultaneous blood temperature control and blood volume control reduces intradialytic symptoms.
Veljančic L; Popović J; Radović M; Ahrenholz P; Ries W; Frenken L; Wojke R
Int J Artif Organs; 2011 Apr; 34(4):357-64. PubMed ID: 21534246
[TBL] [Abstract][Full Text] [Related]
7. Relative blood volume based biofeedback during haemodialysis.
Dasselaar JJ
J Ren Care; 2007; 33(2):59-65. PubMed ID: 17702507
[TBL] [Abstract][Full Text] [Related]
8. Clinical significance of intradialytic blood volume monitoring.
Santoro A; Mancini E
Int J Artif Organs; 1997 Jan; 20(1):1-6. PubMed ID: 9062823
[No Abstract] [Full Text] [Related]
9. Non-invasive monitoring of hemodynamic parameters during hemodialysis.
Pizzarelli F; Dattolo P; Piacenti M; Morales MA; Cerrai T; Maggiore Q
Int J Artif Organs; 1995 Sep; 18(9):499-503. PubMed ID: 8582765
[TBL] [Abstract][Full Text] [Related]
10. [Effect of automated blood volume control on the incidence of intra-dialysis hypotension].
Germin Petrović D
Acta Med Croatica; 2003; 57(1):17-22. PubMed ID: 12876857
[TBL] [Abstract][Full Text] [Related]
11. Predicting episodes of hypotension by continuous blood volume monitoring among critically ill patients in acute renal failure on intermittent hemodialysis.
Tanguay TA; Jensen L; Johnston C
Dynamics; 2007; 18(3):19-24. PubMed ID: 17879763
[TBL] [Abstract][Full Text] [Related]
12. CRIT-LINE: a noninvasive tool to monitor hemoglobin levels in pediatric hemodialysis patients.
Garro R; Sutherland S; Bayes L; Alexander S; Wong C
Pediatr Nephrol; 2015 Jun; 30(6):991-8. PubMed ID: 25854612
[TBL] [Abstract][Full Text] [Related]
13. Noninvasive Hemoglobin Monitoring: A Rapid, Reliable, and Cost-Effective Method Following Total Joint Replacement.
Martin JR; Camp CL; Stitz A; Young EY; Abdel MP; Taunton MJ; Trousdale RT
J Bone Joint Surg Am; 2016 Mar; 98(5):349-55. PubMed ID: 26935456
[TBL] [Abstract][Full Text] [Related]
14. Continuous measurement of blood volume during hemodialysis by an optical method.
de Vries JP; Olthof CG; Visser V; Kouw PM; van Es A; Donker JM; de Vries PM
ASAIO J; 1992; 38(3):M181-5. PubMed ID: 1457844
[TBL] [Abstract][Full Text] [Related]
15. Is there also a critical BV for minor intra-dialytic complaints?
Moret VK; Kooman J; Gerlag PG; van der Sande FM; van den Wall Bake AW
Nephrol Dial Transplant; 2004 Mar; 19(3):750; author reply 750-1. PubMed ID: 14767047
[No Abstract] [Full Text] [Related]
16. Effects of automatic blood volume control over intradialytic hemodynamic stability.
Mancini E; Santoro A; Spongano M; Paolini F; Zucchelli P
Int J Artif Organs; 1995 Sep; 18(9):495-8. PubMed ID: 8582764
[TBL] [Abstract][Full Text] [Related]
17. Interactive hemodialysis control system for improved cardiovascular stability.
Klein E; Wathen RL
Med Instrum; 1986; 20(2):80-4. PubMed ID: 3702784
[No Abstract] [Full Text] [Related]
18. Can advances in hemodialysis machine technology prevent intradialytic hypotension?
Davenport A
Semin Dial; 2009; 22(3):231-6. PubMed ID: 19572996
[TBL] [Abstract][Full Text] [Related]
19. Online Hemoglobin and Oxygen Saturation Sensing During Continuous Renal Replacement Therapy with Regional Citrate Anticoagulation.
Yessayan LT; Yee J; Frinak S; Szamosfalvi B
ASAIO J; 2015; 61(5):489-95. PubMed ID: 24561458
[TBL] [Abstract][Full Text] [Related]
20. Using dialysis machine technology to reduce intradialytic hypotension.
Davenport A
Hemodial Int; 2011 Oct; 15 Suppl 1():S37-42. PubMed ID: 22093599
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]