These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
22. Low-energy transvenous cardioversion defibrillation of atrial tachyarrhythmias in the canine: an assessment of electrode configurations and monophasic pulse sequencing. Benditt DG; Dunbar D; Fetter J; Sakaguchi S; Lurie KG; Adler SW Am Heart J; 1994 Apr; 127(4 Pt 2):994-1003. PubMed ID: 8160604 [TBL] [Abstract][Full Text] [Related]
23. Utility of low energy test shocks for estimation of cardiac and electrode impedance with implantable defibrillators. Leitch JW; Yee R; Klein GJ; Jones DL Pacing Clin Electrophysiol; 1990 Apr; 13(4):410-6. PubMed ID: 1692124 [TBL] [Abstract][Full Text] [Related]
24. Reduction of the internal atrial defibrillation threshold with balanced orthogonal sequential shocks. Zheng X; Benser ME; Walcott GP; Smith WM; Ideker RE J Cardiovasc Electrophysiol; 2002 Sep; 13(9):904-9. PubMed ID: 12380930 [TBL] [Abstract][Full Text] [Related]
25. [Temporary adjustable defibrillator electrodes: an alternative method for the treatment of postoperative arrhythmias after heart surgery]. Mehmanesh H; Mieck U; Bauernschmitt R; Hagl S; Lange R Anasthesiol Intensivmed Notfallmed Schmerzther; 1999 Dec; 34(12):758-62. PubMed ID: 10665311 [TBL] [Abstract][Full Text] [Related]
26. Leakage of energy to the body surface during defibrillation shock by an implantable cardioverter-defibrillator (ICD) system--experimental evaluation during defibrillation shocks through the right ventricular lead and the subcutaneous active-can in canines. Niwano S; Kitano Y; Moriguchi M; Yoshizawa N; Kashiwa T; Suyama M; Toyoshima T; Izumi T Jpn Circ J; 2001 Mar; 65(3):219-25. PubMed ID: 11266198 [TBL] [Abstract][Full Text] [Related]
27. Efficacy and safety of monophasic and biphasic waveform shocks using a braided endocardial defibrillation lead system. Saksena S; Scott SE; Accorti PR; Boveja BK; Abels D; Callaghan FJ Am Heart J; 1990 Dec; 120(6 Pt 1):1342-7. PubMed ID: 2248181 [TBL] [Abstract][Full Text] [Related]
28. Comparison of the defibrillation threshold and the upper limit of ventricular vulnerability. Chen PS; Shibata N; Dixon EG; Martin RO; Ideker RE Circulation; 1986 May; 73(5):1022-8. PubMed ID: 3698224 [TBL] [Abstract][Full Text] [Related]
29. Initial clinical experience with endocardial defibrillation using an implantable cardioverter/defibrillator with a triple-electrode system. Saksena S; Tullo NG; Krol RB; Mauro AM Arch Intern Med; 1989 Oct; 149(10):2333-9. PubMed ID: 2802898 [TBL] [Abstract][Full Text] [Related]
30. Intracavitary electrode catheter cardioversion of atrial tachyarrhythmias in the dog. Dunbar DN; Tobler HG; Fetter J; Gornick CC; Benson DW; Benditt DG J Am Coll Cardiol; 1986 May; 7(5):1015-27. PubMed ID: 3958358 [TBL] [Abstract][Full Text] [Related]
31. The effects of atrial electrical remodeling on atrial defibrillation thresholds. Everett TH; Li H; Mangrum JM; Mastrangelo C; Haines DE Pacing Clin Electrophysiol; 2001 Aug; 24(8 Pt 1):1208-15. PubMed ID: 11523605 [TBL] [Abstract][Full Text] [Related]