250 related articles for article (PubMed ID: 8584299)
1. Restoration of functional gait in paraplegic patients with the RGO-II hybrid orthosis. A multicentre controlled study. I. Clinical evaluation.
Thoumie P; Perrouin-Verbe B; Le Claire G; Bedoiseau M; Busnel M; Cormerais A; Courtillon A; Mathe JF; Moutet F; Nadeau G
Paraplegia; 1995 Nov; 33(11):647-53. PubMed ID: 8584299
[TBL] [Abstract][Full Text] [Related]
2. Restoration of functional gait in paraplegic patients with the RGO-II hybrid orthosis. A multicenter controlled study. II: Physiological evaluation.
Thoumie P; Le Claire G; Beillot J; Dassonville J; Chevalier T; Perrouin-Verbe B; Bedoiseau M; Busnel M; Cormerais A; Courtillon A
Paraplegia; 1995 Nov; 33(11):654-9. PubMed ID: 8584300
[TBL] [Abstract][Full Text] [Related]
3. Gait evaluation of a novel hip constraint orthosis with implication for walking in paraplegia.
Audu ML; To CS; Kobetic R; Triolo RJ
IEEE Trans Neural Syst Rehabil Eng; 2010 Dec; 18(6):610-8. PubMed ID: 20378478
[TBL] [Abstract][Full Text] [Related]
4. Ambulation study of a woman with paraplegia using a reciprocating gait orthosis with functional electrical stimulation in Taiwan: a case report.
Chen WL; Chang WH; Chen CC; Hsieh JC; Shih YY; Chen YL
Disabil Rehabil Assist Technol; 2009 Nov; 4(6):429-38. PubMed ID: 19817657
[TBL] [Abstract][Full Text] [Related]
5. Restoration of gait with orthoses in thoracic paraplegia: a multicentric investigation.
Lotta S; Fiocchi A; Giovannini R; Silvestrin R; Tesio L; Raschi A; Macchia L; Chiapatti V; Zambelli M; Tosi C
Paraplegia; 1994 Sep; 32(9):608-15. PubMed ID: 7997340
[TBL] [Abstract][Full Text] [Related]
6. Restoration of gait by functional electrical stimulation for spinal cord injured patients.
Gallien P; Brissot R; Eyssette M; Tell L; Barat M; Wiart L; Petit H
Paraplegia; 1995 Nov; 33(11):660-4. PubMed ID: 8584301
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of the performance of paraplegic subjects during walking with a new design of reciprocal gait orthosis.
Karimi MT; Fatoye F
Disabil Rehabil Assist Technol; 2016; 11(1):72-9. PubMed ID: 25069902
[TBL] [Abstract][Full Text] [Related]
8. Design and simulation of a new powered gait orthosis for paraplegic patients.
Arazpour M; Chitsazan A; Hutchins SW; Ghomshe FT; Mousavi ME; Takamjani EE; Aminian G; Rahgozar M; Bani MA
Prosthet Orthot Int; 2012 Mar; 36(1):125-30. PubMed ID: 22235109
[TBL] [Abstract][Full Text] [Related]
9. The Physiological Cost Index of walking with an isocentric reciprocating gait orthosis among patients with T(12) - L(1) spinal cord injury.
Leung AK; Wong AF; Wong EC; Hutchins SW
Prosthet Orthot Int; 2009 Mar; 33(1):61-8. PubMed ID: 19235067
[TBL] [Abstract][Full Text] [Related]
10. Effect of powered gait orthosis on walking in individuals with paraplegia.
Arazpour M; Ahmadi Bani M; Kashani RV; Tabatabai Ghomshe F; Mousavi ME; Hutchins SW
Prosthet Orthot Int; 2013 Aug; 37(4):261-7. PubMed ID: 23172910
[TBL] [Abstract][Full Text] [Related]
11. Energy consumption in paraplegic ambulation using the reciprocating gait orthosis and electric stimulation of the thigh muscles.
Hirokawa S; Grimm M; Le T; Solomonow M; Baratta RV; Shoji H; D'Ambrosia RD
Arch Phys Med Rehabil; 1990 Aug; 71(9):687-94. PubMed ID: 2375676
[TBL] [Abstract][Full Text] [Related]
12. Influence of orthotic gait training with powered hip orthosis on walking in paraplegic patients.
Arazpour M; Bani MA; Hutchins SW; Curran S; Javanshir MA; Mousavi ME
Disabil Rehabil Assist Technol; 2014 May; 9(3):226-30. PubMed ID: 24749556
[TBL] [Abstract][Full Text] [Related]
13. Design of the Wearable Power-Assist Locomotor (WPAL) for paraplegic gait reconstruction.
Tanabe S; Saitoh E; Hirano S; Katoh M; Takemitsu T; Uno A; Shimizu Y; Muraoka Y; Suzuki T
Disabil Rehabil Assist Technol; 2013 Jan; 8(1):84-91. PubMed ID: 22612673
[TBL] [Abstract][Full Text] [Related]
14. [Beneficial effects of reciprocating gait orthosis on bladder and bowel functions in paraplegia patients].
Sun JL; Zhong SZ; Ouyang YT; Tang D; Xian QL
Nan Fang Yi Ke Da Xue Xue Bao; 2008 Jun; 28(6):1019-21. PubMed ID: 18583253
[TBL] [Abstract][Full Text] [Related]
15. Sensor-based hip control with hybrid neuroprosthesis for walking in paraplegia.
To CS; Kobetic R; Bulea TC; Audu ML; Schnellenberger JR; Pinault G; Triolo RJ
J Rehabil Res Dev; 2014; 51(2):229-44. PubMed ID: 24933721
[TBL] [Abstract][Full Text] [Related]
16. Ambulation using the reciprocating gait orthosis and functional electrical stimulation.
Isakov E; Douglas R; Berns P
Paraplegia; 1992 Apr; 30(4):239-45. PubMed ID: 1625891
[TBL] [Abstract][Full Text] [Related]
17. Physiologic costs of reciprocal gait in FES assisted walking.
Winchester P; Carollo JJ; Habasevich R
Paraplegia; 1994 Oct; 32(10):680-6. PubMed ID: 7831075
[TBL] [Abstract][Full Text] [Related]
18. Vannini-Rizzoli stabilizing orthosis (boot): preliminary report on a new ambulatory aid for spinal cord injury.
Kent HO
Arch Phys Med Rehabil; 1992 Mar; 73(3):302-7. PubMed ID: 1543438
[TBL] [Abstract][Full Text] [Related]
19. The Araz medial linkage orthosis: a new orthosis for walking in patients with spinal cord injury: a single patient study.
Arazpour M; Bani MA; Hutchins SW; Sayyadfar M
Prosthet Orthot Int; 2014 Apr; 38(2):155-9. PubMed ID: 23798043
[TBL] [Abstract][Full Text] [Related]
20. Muscle force and gait performance: relationships after spinal cord injury.
Wirz M; van Hedel HJ; Rupp R; Curt A; Dietz V
Arch Phys Med Rehabil; 2006 Sep; 87(9):1218-22. PubMed ID: 16935058
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]