100 related articles for article (PubMed ID: 8584823)
1. Stereotactic localization using magnetic resonance imaging.
Walton L; Hampshire A; Forster DM; Kemeny AA
Stereotact Funct Neurosurg; 1995; 64 Suppl 1():155-63. PubMed ID: 8584823
[TBL] [Abstract][Full Text] [Related]
2. A phantom study to assess the accuracy of stereotactic localization, using T1-weighted magnetic resonance imaging with the Leksell stereotactic system.
Walton L; Hampshire A; Forster DM; Kemeny AA
Neurosurgery; 1996 Jan; 38(1):170-6; discussion 176-8. PubMed ID: 8747966
[TBL] [Abstract][Full Text] [Related]
3. Assessment of MR stereotactic imaging and image co-registration accuracy for 3 different MR scanners by 3 different methods/phantoms: phantom and patient study.
Paštyková V; Novotný J; Veselský T; Urgošík D; Liščák R; Vymazal J
J Neurosurg; 2018 Dec; 129(Suppl1):125-132. PubMed ID: 30544292
[TBL] [Abstract][Full Text] [Related]
4. Stereotactic localization with magnetic resonance imaging: a phantom study to compare the accuracy obtained using two-dimensional and three-dimensional data acquisitions.
Walton L; Hampshire A; Forster DM; Kemeny AA
Neurosurgery; 1997 Jul; 41(1):131-7; discussion 137-9. PubMed ID: 9218305
[TBL] [Abstract][Full Text] [Related]
5. Accuracy of stereotactic coordinate transformation using a localisation frame and computed tomographic imaging. Part II. Analysis of matrix-based coordinate transformation.
Grunert P
Neurosurg Rev; 1999 Dec; 22(4):188-203; discussion 204. PubMed ID: 10682927
[TBL] [Abstract][Full Text] [Related]
6. A phantom study of the geometric accuracy of computed tomographic and magnetic resonance imaging stereotactic localization with the Leksell stereotactic system.
Yu C; Apuzzo ML; Zee CS; Petrovich Z
Neurosurgery; 2001 May; 48(5):1092-8; discussion 1098-9. PubMed ID: 11334276
[TBL] [Abstract][Full Text] [Related]
7. Stereotactic accuracy of a 3-tesla magnetic resonance unit.
Azmi H; Schulder M
Stereotact Funct Neurosurg; 2003; 80(1-4):140-5. PubMed ID: 14745224
[TBL] [Abstract][Full Text] [Related]
8. Accuracy of stereotactic localisation using magnetic resonance imaging: a comparison between two- and three-dimensional studies.
Walton L; Hampshire A; Forster DM; Kemeny AA
Stereotact Funct Neurosurg; 1996; 66 Suppl 1():49-56. PubMed ID: 9032844
[TBL] [Abstract][Full Text] [Related]
9. Magnetic resonance imaging stereotactic target localization for deep brain stimulation in dystonic children.
Vayssiere N; Hemm S; Zanca M; Picot MC; Bonafe A; Cif L; Frerebeau P; Coubes P
J Neurosurg; 2000 Nov; 93(5):784-90. PubMed ID: 11059658
[TBL] [Abstract][Full Text] [Related]
10. A simple method for evaluating stereotactic accuracy of Magnetic Resonance Imaging and Computed Tomography Imaging in Frame Based Radiosurgery.
Sajeev T; Musthafa M; Sampath S; Indiradevi B; Bhanumathy G; Supe SS
Gulf J Oncolog; 2013 Jul; 1(14):6-13. PubMed ID: 23996861
[TBL] [Abstract][Full Text] [Related]
11. Stereotactic target localization accuracy in interventional magnetic resonance imaging.
Samset E; Hirschberg H
Stereotact Funct Neurosurg; 2002; 79(3-4):191-201. PubMed ID: 12890977
[TBL] [Abstract][Full Text] [Related]
12. Development of a unique phantom to assess the geometric accuracy of magnetic resonance imaging for stereotactic localization.
Orth RC; Sinha P; Madsen EL; Frank G; Korosec FR; Mackie TR; Mehta MP
Neurosurgery; 1999 Dec; 45(6):1423-9; discussion 1429-31. PubMed ID: 10598710
[TBL] [Abstract][Full Text] [Related]
13. MRI distortion and stereotactic neurosurgery using the Cosman-Roberts-Wells and Leksell frames.
Burchiel KJ; Nguyen TT; Coombs BD; Szumoski J
Stereotact Funct Neurosurg; 1996; 66(1-3):123-36. PubMed ID: 8938944
[TBL] [Abstract][Full Text] [Related]
14. A prospective comparison between three-dimensional magnetic resonance imaging and ventriculography for target-coordinate determination in frame-based functional stereotactic neurosurgery.
Schuurman PR; de Bie RM; Majoie CB; Speelman JD; Bosch DA
J Neurosurg; 1999 Dec; 91(6):911-4. PubMed ID: 10584834
[TBL] [Abstract][Full Text] [Related]
15. A Phantom Study of the Spatial Precision and Accuracy of Stereotactic Localization Using Computed Tomography Imaging with the Leksell Stereotactic System.
Tafreshi AR; Peng T; Yu C; Kramer DR; Gogia AS; Lee MB; Barbaro MF; Sebastian R; Del Campo-Vera RM; Chen KH; Kellis SS; Lee B
World Neurosurg; 2020 Jul; 139():e297-e307. PubMed ID: 32298832
[TBL] [Abstract][Full Text] [Related]
16. Geometric accuracy in three-dimensional coordinates of Leksell stereotactic skull frame with wide-bore 1.5-T MRI compared with conventional 1.5-T MRI.
Nakazawa H; Komori M; Shibamoto Y; Takikawa Y; Mori Y; Tsugawa T
J Med Imaging Radiat Oncol; 2014 Oct; 58(5):595-600. PubMed ID: 25124316
[TBL] [Abstract][Full Text] [Related]
17. Accuracy of magnetic resonance imaging stereotactic coordinates with the cosman-roberts-wells frame.
Carter DA; Parsai EI; Ayyangar KM
Stereotact Funct Neurosurg; 1999; 72(1):35-46. PubMed ID: 10640919
[TBL] [Abstract][Full Text] [Related]
18. Image-guided stereotaxy in the interventional MRI.
Samset E; Hirschberg H
Minim Invasive Neurosurg; 2003 Feb; 46(1):5-10. PubMed ID: 12640576
[TBL] [Abstract][Full Text] [Related]
19. Analysis of Stereotactic Accuracy in Patients Undergoing Deep Brain Stimulation Using Nexframe and the Leksell Frame.
Bot M; van den Munckhof P; Bakay R; Sierens D; Stebbins G; Verhagen Metman L
Stereotact Funct Neurosurg; 2015; 93(5):316-25. PubMed ID: 26227179
[TBL] [Abstract][Full Text] [Related]
20. MRI-guided stereotaxic targeting in pigs based on a stereotaxic localizer box fitted with an isocentric frame and use of SurgiPlan computer-planning software.
Bjarkam CR; Cancian G; Glud AN; Ettrup KS; Jørgensen RL; Sørensen JC
J Neurosci Methods; 2009 Oct; 183(2):119-26. PubMed ID: 19559051
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]