BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

513 related articles for article (PubMed ID: 8596834)

  • 21. Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy.
    Khan MF; Straub R; Moghaddam SR; Maataoui A; Gurung J; Wagner TO; Ackermann H; Thalhammer A; Vogl TJ; Jacobi V
    Eur Radiol; 2008 Jul; 18(7):1356-63. PubMed ID: 18351356
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Pneumothorax, pleural effusion, and chest tube placement after radiofrequency ablation of lung tumors: incidence and risk factors.
    Hiraki T; Tajiri N; Mimura H; Yasui K; Gobara H; Mukai T; Hase S; Fujiwara H; Iguchi T; Sano Y; Shimizu N; Kanazawa S
    Radiology; 2006 Oct; 241(1):275-83. PubMed ID: 16908680
    [TBL] [Abstract][Full Text] [Related]  

  • 23. CT-guided lung biopsies: pleural blood patching reduces the rate of chest tube placement for postbiopsy pneumothorax.
    Wagner JM; Hinshaw JL; Lubner MG; Robbins JB; Kim DH; Pickhardt PJ; Lee FT
    AJR Am J Roentgenol; 2011 Oct; 197(4):783-8. PubMed ID: 21940564
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Risk factors for pneumothorax and bleeding after CT-guided percutaneous coaxial cutting needle biopsy of lung lesions.
    Yeow KM; See LC; Lui KW; Lin MC; Tsao TC; Ng KF; Liu HP
    J Vasc Interv Radiol; 2001 Nov; 12(11):1305-12. PubMed ID: 11698630
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Efficacy of the tract embolization technique with gelatin sponge slurry to reduce pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy.
    Renier H; Gérard L; Lamborelle P; Cousin F
    Cardiovasc Intervent Radiol; 2020 Apr; 43(4):597-603. PubMed ID: 31792589
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Pneumothoraxes after CT-guided percutaneous transthoracic needle aspiration biopsy of the lung: A single-center experience with 3426 patients.
    Polat G; Özdemir Ö; Serçe Unat D; Karadeniz G; Ayrancı A; Unat ÖS; Büyükşirin M; Maviş A; Yazgan S
    Tuberk Toraks; 2023 Mar; 71(1):67-74. PubMed ID: 36912411
    [TBL] [Abstract][Full Text] [Related]  

  • 27. CT-guided transthoracic needle biopsy using a puncture site-down positioning technique.
    Kinoshita F; Kato T; Sugiura K; Nishimura M; Kinoshita T; Hashimoto M; Kaminoh T; Ogawa T
    AJR Am J Roentgenol; 2006 Oct; 187(4):926-32. PubMed ID: 16985136
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Percutaneous transthoracic needle biopsy of the lung: review of 612 lesions.
    Swischuk JL; Castaneda F; Patel JC; Li R; Fraser KW; Brady TM; Bertino RE
    J Vasc Interv Radiol; 1998; 9(2):347-52. PubMed ID: 9540921
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients.
    Nour-Eldin NE; Alsubhi M; Emam A; Lehnert T; Beeres M; Jacobi V; Gruber-Rouh T; Scholtz JE; Vogl TJ; Naguib NN
    Cardiovasc Intervent Radiol; 2016 Feb; 39(2):261-70. PubMed ID: 26148648
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Pneumothorax with prolonged chest tube requirement after CT-guided percutaneous lung biopsy: incidence and risk factors.
    Moreland A; Novogrodsky E; Brody L; Durack J; Erinjeri J; Getrajdman G; Solomon S; Yarmohammadi H; Maybody M
    Eur Radiol; 2016 Oct; 26(10):3483-91. PubMed ID: 26787605
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Retrospective analysis of technical success rate and procedure-related complications of 867 percutaneous CT-guided needle biopsies of lung lesions.
    Mills M; Choi J; El-Haddad G; Sweeney J; Biebel B; Robinson L; Antonia S; Kumar A; Kis B
    Clin Radiol; 2017 Dec; 72(12):1038-1046. PubMed ID: 28851490
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Pulmonary Intraparenchymal Blood Patching Decreases the Rate of Pneumothorax-Related Complications following Percutaneous CT-Guided Needle Biopsy.
    Graffy P; Loomis SB; Pickhardt PJ; Lubner MG; Kitchin DR; Lee FT; Hinshaw JL
    J Vasc Interv Radiol; 2017 Apr; 28(4):608-613.e1. PubMed ID: 28185770
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [The factor analysis of the incidence of complication in CT-guided lung automated cutting needle biopsy with extrapleural locating method].
    Liao MY; Zhou YF; Tian ZX; Luo R; Qu YJ; Xu LY
    Zhonghua Yi Xue Za Zhi; 2010 Jul; 90(25):1747-51. PubMed ID: 20979891
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules.
    Li H; Boiselle PM; Shepard JO; Trotman-Dickenson B; McLoud TC
    AJR Am J Roentgenol; 1996 Jul; 167(1):105-9. PubMed ID: 8659351
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Evaluation of risk factors in pneumothorax development after computerized tomography-guided transthoracic biopsy and management of complications.
    Kolu M; Yildirim IO
    Niger J Clin Pract; 2020 Feb; 23(2):246-251. PubMed ID: 32031101
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Core Lung Biopsy for Biomarker Analysis: Is There Increased Risk Compared With Conventional Biopsy?
    Sheth S; Jilani D; Bos A; Ahmed O; Patel M; Zangan S
    J Thorac Imaging; 2015 Sep; 30(5):314-8. PubMed ID: 25961378
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Incidence and risk factors of delayed pneumothorax after transthoracic needle biopsy of the lung.
    Choi CM; Um SW; Yoo CG; Kim YW; Han SK; Shim YS; Lee CT
    Chest; 2004 Nov; 126(5):1516-21. PubMed ID: 15539721
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effect of intraparenchymal blood patch on rates of pneumothorax and pneumothorax requiring chest tube placement after percutaneous lung biopsy.
    Malone LJ; Stanfill RM; Wang H; Fahey KM; Bertino RE
    AJR Am J Roentgenol; 2013 Jun; 200(6):1238-43. PubMed ID: 23701059
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A novel technique for CT-guided transthoracic biopsy of lung lesions: improved biopsy accuracy and safety.
    Yaffe D; Koslow M; Haskiya H; Shitrit D
    Eur Radiol; 2015 Nov; 25(11):3354-60. PubMed ID: 25903714
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy.
    Min L; Xu X; Song Y; Issahar BD; Wu J; Zhang L; Huang Q; Chen M
    Eur J Radiol; 2013 Jan; 82(1):187-90. PubMed ID: 23068560
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 26.