148 related articles for article (PubMed ID: 8600099)
1. Comparison of dose homogeneity effects due to electron equilibrium loss in lung for 6 MV and 18 MV photons.
White PJ; Zwicker RD; Huang DT
Int J Radiat Oncol Biol Phys; 1996 Mar; 34(5):1141-6. PubMed ID: 8600099
[TBL] [Abstract][Full Text] [Related]
2. Dosimetric advantage of using 6 MV over 15 MV photons in conformal therapy of lung cancer: Monte Carlo studies in patient geometries.
Wang L; Yorke E; Desobry G; Chui CS
J Appl Clin Med Phys; 2002; 3(1):51-9. PubMed ID: 11818004
[TBL] [Abstract][Full Text] [Related]
3. Effect of low-density lateral interfaces on soft-tissue doses.
Hunt MA; Desobry GE; Fowble B; Coia LR
Int J Radiat Oncol Biol Phys; 1997 Jan; 37(2):475-82. PubMed ID: 9069324
[TBL] [Abstract][Full Text] [Related]
4. Impact of beam energy and field margin on penumbra at lung tumor-lung parenchyma interfaces.
Miller RC; Bonner JA; Kline RW
Int J Radiat Oncol Biol Phys; 1998 Jun; 41(3):707-13. PubMed ID: 9635723
[TBL] [Abstract][Full Text] [Related]
5. Monte-Carlo-computed dose, kerma and fluence distributions in heterogeneous slab geometries irradiated by small megavoltage photon fields.
Kumar S; Nahum AE; Chetty IJ
Phys Med Biol; 2020 Sep; 65(17):175012. PubMed ID: 32485691
[TBL] [Abstract][Full Text] [Related]
6. Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.
Chibani O; Ma CM
Med Phys; 2003 Aug; 30(8):1990-2000. PubMed ID: 12945965
[TBL] [Abstract][Full Text] [Related]
7. Dosimetric comparison of extended dose range film with ionization measurements in water and lung equivalent heterogeneous media exposed to megavoltage photons.
Charland PM; Chetty IJ; Yokoyama S; Fraass BA
J Appl Clin Med Phys; 2003; 4(1):25-39. PubMed ID: 12540816
[TBL] [Abstract][Full Text] [Related]
8. Analysis of the penumbra enlargement in lung versus the quality index of photon beams: a methodology to check the dose calculation algorithm.
Tsiakalos MF; Theodorou K; Kappas C; Zefkili S; Rosenwold JC
Med Phys; 2004 Apr; 31(4):943-9. PubMed ID: 15125013
[TBL] [Abstract][Full Text] [Related]
9. Testing of the analytical anisotropic algorithm for photon dose calculation.
Van Esch A; Tillikainen L; Pyykkonen J; Tenhunen M; Helminen H; Siljamäki S; Alakuijala J; Paiusco M; Lori M; Huyskens DP
Med Phys; 2006 Nov; 33(11):4130-48. PubMed ID: 17153392
[TBL] [Abstract][Full Text] [Related]
10. Beam perturbation characteristics of a 2D transmission silicon diode array, Magic Plate.
Alrowaili ZA; Lerch ML; Petasecca M; Carolan MG; Metcalfe PE; Rosenfeld AB
J Appl Clin Med Phys; 2016 Mar; 17(2):85-98. PubMed ID: 27074475
[TBL] [Abstract][Full Text] [Related]
11. Pitfalls in the use of high energy X rays to treat tumors in the lung.
Ekstrand KE; Barnes WH
Int J Radiat Oncol Biol Phys; 1990 Jan; 18(1):249-52. PubMed ID: 2105286
[TBL] [Abstract][Full Text] [Related]
12. Matching extended-SSD electron beams to multileaf collimated photon beams in the treatment of head and neck cancer.
Steel J; Stewart A; Satory P
Med Phys; 2009 Sep; 36(9):4244-9. PubMed ID: 19810498
[TBL] [Abstract][Full Text] [Related]
13. [Dosage inhomogeneities in the matching of opposing photon fields and electron fields in head-neck tumors ].
Thesen N; Hoevels M; Treuer H
Strahlenther Onkol; 1995 Apr; 171(4):231-7. PubMed ID: 7740411
[TBL] [Abstract][Full Text] [Related]
14. Dosimetric comparison of flattened and unflattened beams for stereotactic ablative radiotherapy of stage I non-small cell lung cancer.
Hrbacek J; Lang S; Graydon SN; Klöck S; Riesterer O
Med Phys; 2014 Mar; 41(3):031709. PubMed ID: 24593713
[TBL] [Abstract][Full Text] [Related]
15. Monte Carlo dosimetric evaluation of high energy vs low energy photon beams in low density tissues.
Tsiakalos MF; Stathakis S; Plataniotis GA; Kappas C; Theodorou K
Radiother Oncol; 2006 Apr; 79(1):131-8. PubMed ID: 16618511
[TBL] [Abstract][Full Text] [Related]
16. Out-of-field doses and neutron dose equivalents for electron beams from modern Varian and Elekta linear accelerators.
Cardenas CE; Nitsch PL; Kudchadker RJ; Howell RM; Kry SF
J Appl Clin Med Phys; 2016 Jul; 17(4):442-455. PubMed ID: 27455499
[TBL] [Abstract][Full Text] [Related]
17. Sharpening the penumbra of high energy electron beams with low weight narrow photon beams.
Korevaar EW; van Vliet RJ; Woudstra E; Heijmen BJ; Huizenga H
Radiother Oncol; 1998 Aug; 48(2):213-20. PubMed ID: 9783895
[TBL] [Abstract][Full Text] [Related]
18. The response of a radiophotoluminescent glass dosimeter in megavoltage photon and electron beams.
Araki F; Ohno T
Med Phys; 2014 Dec; 41(12):122102. PubMed ID: 25471975
[TBL] [Abstract][Full Text] [Related]
19. Beam intensity modulation to reduce the field sizes for conformal irradiation of lung tumors: a dosimetric study.
Brugmans MJ; van der Horst A; Lebesque JV; Mijnheer BJ
Int J Radiat Oncol Biol Phys; 1999 Mar; 43(4):893-904. PubMed ID: 10098446
[TBL] [Abstract][Full Text] [Related]
20. EGSNRC Monte Carlo study of the effect of photon energy and field margin in phantoms simulating small lung lesions.
Osei EK; Darko J; Mosseri A; Jezioranski J
Med Phys; 2003 Oct; 30(10):2706-14. PubMed ID: 14596309
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]