BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 8602608)

  • 1. Laboratory evaluation of the Abbott Cell DYN 3500 5-part differential.
    Fournier M; Gireau A; Chretien MC; Ghevaert C; Boniface B; Goudemand J; Cosson A
    Am J Clin Pathol; 1996 Mar; 105(3):286-92. PubMed ID: 8602608
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Automated leucocyte differentials in 292 patients with leucopenia: an evaluation of the Abbott CELL-DYN 3500 (CD3500) haematology analyser.
    Burchert-Graeve M; Kock R
    Clin Lab Haematol; 1996 Dec; 18(4):253-9. PubMed ID: 9054698
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation and performance of the Coulter STKS.
    Verheul FE; Spitters JM; Bergmans CH
    Eur J Clin Chem Clin Biochem; 1993 Mar; 31(3):179-86. PubMed ID: 8490065
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation and use of the white blood cell differential provided by the Coulter STKS in a children's hospital.
    Fournier M; Adenis C; Fontaine H; Carnaille B; Goudemand J
    Clin Lab Haematol; 1994 Mar; 16(1):33-42. PubMed ID: 8039345
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Two-centre evaluation of the Abbott CD3500 blood counter.
    al-Ismail SA; Bond K; Carter AB; Grant D; Machin SJ; Patterson KG; Pearman KJ; Pollard YC; Popeck M
    Clin Lab Haematol; 1995 Mar; 17(1):11-21. PubMed ID: 7621623
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of the Coulter STKS five-part differential.
    Cornbleet PJ; Myrick D; Levy R
    Am J Clin Pathol; 1993 Jan; 99(1):72-81. PubMed ID: 8422021
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance evaluation of the Sysmex XN-1000 hematology analyzer in assessment of the white blood cell count differential in pediatric specimens.
    Becker PH; Fenneteau O; Da Costa L
    Int J Lab Hematol; 2016 Feb; 38(1):54-63. PubMed ID: 26407903
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of the Abbott Cell Dyn 3000 SL and the Coulter STKS hematology analyzers.
    Stroop DM; Triplett RC; Perrotta G; Roberts LP; Schramm RC; Comer K; Miller-Canfield P; Schumacher HR
    Ann Clin Lab Sci; 1994; 24(3):250-8. PubMed ID: 8048797
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automated five-part white blood cell differential counts. Efficiency of software-generated white blood cell suspect flags of the hematology analyzers Sysmex SE-9000, Sysmex NE-8000, and Coulter STKS.
    Thalhammer-Scherrer R; Knöbl P; Korninger L; Schwarzinger I
    Arch Pathol Lab Med; 1997 Jun; 121(6):573-7. PubMed ID: 9199621
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Studies on the efficient application by STKS and 8200].
    Mishima S; Unshima T; Yoshida Y; Endo J
    Rinsho Byori; 1992 Jun; 40(6):577-85. PubMed ID: 1513029
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance of the Coulter STKS and the Sysmex NE-1500 in a paediatric population.
    Moreau E; Philippé J; Kint J; Benoit Y; Leroux-Roels G
    Eur J Clin Chem Clin Biochem; 1994 Jul; 32(7):563-6. PubMed ID: 7981339
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Diagnostic performance of the variant lymphocyte flag of the Abbott Cell-Dyn 4000 haematology analyser.
    Hoffmann JJ; Hoedemakers RM
    Clin Lab Haematol; 2004 Feb; 26(1):9-13. PubMed ID: 14738431
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Complete analytical and diagnostic performances of the Abbott Cell Dyn 3500.
    Sanzari M; De Toni S; D'Osualdo A; Rossetti M; Floriani F; Plebani M
    Panminerva Med; 1998 Jun; 40(2):116-25. PubMed ID: 9689832
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diagnostic performance: a comparative study of the leukocyte differential count on four automated haematology analysers.
    Buttarello M; Lorenz C; Gadotti M; Toffalori E; Valentini A; Rizzotti P
    Eur J Clin Chem Clin Biochem; 1993 Apr; 31(4):251-8. PubMed ID: 8318574
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of the ABX Cobas Vega automated hematology analyzer and comparison with the Coulter STKS.
    Ferrero-Vacher C; Sudaka I; Jambou D; Vanhaeke D; Fischer F; Bayle J
    Hematol Cell Ther; 1997 Jun; 39(3):149-58. PubMed ID: 9262992
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An evaluation of leucocyte analysis on the Coulter STKS.
    Robertson EP; Lai HW; Wei DC
    Clin Lab Haematol; 1992; 14(1):53-68. PubMed ID: 1600694
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Precision and accuracy of monocyte counting. Comparison of two hematology analyzers, the manual differential and flow cytometry.
    Hübl W; Hauptlorenz S; Tlustos L; Jilch R; Fischer M; Bayer PM
    Am J Clin Pathol; 1995 Feb; 103(2):167-70. PubMed ID: 7531938
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Manual and automated methods for the determination of leukocyte counts at extreme low levels: comparative evaluation of the Nageotte chamber and the Abbott Cell Dyn 3500 analyser.
    Müller TH; Döscher A; Schunter F; Scott CS
    Transfus Sci; 1997 Dec; 18(4):505-15. PubMed ID: 10178673
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A field evaluation of the Coulter STKS.
    Warner BA; Reardon DM
    Am J Clin Pathol; 1991 Feb; 95(2):207-17. PubMed ID: 1899530
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the CELL-DYN 3000 differential.
    Cornbleet PJ; Myrick D; Judkins S; Levy R
    Am J Clin Pathol; 1992 Dec; 98(6):603-14. PubMed ID: 1462958
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.