BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

976 related articles for article (PubMed ID: 8609355)

  • 1. Coronary stenting with a novel stainless steel balloon-expandable stent: determinants of neointimal formation and changes in arterial geometry after placement in an atherosclerotic model.
    Carter AJ; Laird JR; Kufs WM; Bailey L; Hoopes TG; Reeves T; Farb A; Virmani R
    J Am Coll Cardiol; 1996 Apr; 27(5):1270-7. PubMed ID: 8609355
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experimental Results with the Multi-Linkª Stent in a Porcine Model.
    Thomas WJ; Laird JR; Bailey L; Hoopes TG; Hillhouse R; Scott D; Jones R; Virmani R; Carter AJ
    J Invasive Cardiol; 1997 Sep; 9(7):453-460. PubMed ID: 10762942
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Restenosis following placement of an intracoronary heparin treated tantulum stent in the hyperlipidemic miniature swine model.
    Jenkins JS; Webel R; Laughlin MH; Rowland SM; Yoklavich MF; Amann JF; Branson K; Myers PR
    J Invasive Cardiol; 1995; 7(6):173-82. PubMed ID: 10155102
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Stent-based delivery of ABT-578 via a phosphorylcholine surface coating reduces neointimal formation in the porcine coronary model.
    Collingwood R; Gibson L; Sedlik S; Virmani R; Carter AJ
    Catheter Cardiovasc Interv; 2005 Jun; 65(2):227-32. PubMed ID: 15900559
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Paclitaxel balloon coating, a novel method for prevention and therapy of restenosis.
    Scheller B; Speck U; Abramjuk C; Bernhardt U; Böhm M; Nickenig G
    Circulation; 2004 Aug; 110(7):810-4. PubMed ID: 15302790
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Tyrphostin AGL-2043 eluting stent reduces neointima formation in porcine coronary arteries.
    Banai S; Gertz SD; Gavish L; Chorny M; Perez LS; Lazarovichi G; Ianculuvich M; Hoffmann M; Orlowski M; Golomb G; Levitzki A
    Cardiovasc Res; 2004 Oct; 64(1):165-71. PubMed ID: 15364624
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparative pathology: radiation-induced coronary artery disease in man and animals.
    Virmani R; Farb A; Carter AJ; Jones RM
    Semin Interv Cardiol; 1998; 3(3-4):163-72. PubMed ID: 10406688
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Restenosis is not associated with stent length in a pig model of coronary stent implantation.
    Koutouzis M; Papalois A; Kyrzopoulos S; Dafnomili P; Kyriakides ZS
    Cardiol J; 2008; 15(5):458-62. PubMed ID: 18810722
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The degree of neointimal formation after stent placement in atherosclerotic rabbit iliac arteries is dependent on the underlying plaque.
    Carter AJ; Farb A; Gould KE; Taylor AJ; Virmani R
    Cardiovasc Pathol; 1999; 8(2):73-80. PubMed ID: 10724504
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of the vascular responses to balloon-expandable stenting in the coronary and peripheral circulations: long-term results in an animal model using the TriMaxx stent.
    Dubé H; Clifford AG; Barry CM; Schwarten DE; Schwartz LB
    J Vasc Surg; 2007 Apr; 45(4):821-7. PubMed ID: 17398392
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Stent design favorably influences the vascular response in normal porcine coronary arteries.
    Carter AJ; Scott D; Rahdert D; Bailey L; De Vries J ; Ayerdi K; Turnlund T; Jones R; Virmani R; Fischell TA
    J Invasive Cardiol; 1999 Mar; 11(3):127-34. PubMed ID: 10745499
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Polymer stent coating for prevention of neointimal hyperplasia.
    Billinger M; Buddeberg F; Hubbell JA; Elbert DL; Schaffner T; Mettler D; Windecker S; Meier B; Hess OM
    J Invasive Cardiol; 2006 Sep; 18(9):423-6; discussion 427. PubMed ID: 16954581
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Randomized comparison of J&J Crown stent versus NIR stent after routine coronary angioplasty.
    Miketic S; Carlsson J; Tebbe U
    Am Heart J; 2001 Nov; 142(5):E8. PubMed ID: 11685183
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Expression of intercellular adhesion molecule-1 and vascular cell adhesion molecule-1 in the pig coronary artery injury model: comparison of plain old balloon angioplasty and stent implantation].
    Shimizu N; Suzuki H; Wakabayashi K; Iso Y; Shibata M; Yorozuya M; Katagiri T; Takeyama Y
    J Cardiol; 2004 Mar; 43(3):131-9. PubMed ID: 15067801
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Pressure wire guide provisional coronary stent implantation].
    Nakamura S; Anzai H; Takagi T; Tezuka N; Nakajima R; Inaba N; Tanigawa J; Nakagawa A; Kitano K; Takahashi H; Matoba Y; Katoh O
    J Cardiol; 2001 Apr; 37(4):191-9. PubMed ID: 11337928
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Augmentation of wall shear stress inhibits neointimal hyperplasia after stent implantation: inhibition through reduction of inflammation?
    Carlier SG; van Damme LC; Blommerde CP; Wentzel JJ; van Langehove G; Verheye S; Kockx MM; Knaapen MW; Cheng C; Gijsen F; Duncker DJ; Stergiopulos N; Slager CJ; Serruys PW; Krams R
    Circulation; 2003 Jun; 107(21):2741-6. PubMed ID: 12742998
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reduced acute thrombus formation results in decreased neointimal proliferation after coronary angioplasty.
    Unterberg C; Sandrock D; Nebendahl K; Buchwald AB
    J Am Coll Cardiol; 1995 Dec; 26(7):1747-54. PubMed ID: 7594113
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Angiographic follow-up after placement of a self-expanding coronary-artery stent.
    Serruys PW; Strauss BH; Beatt KJ; Bertrand ME; Puel J; Rickards AF; Meier B; Goy JJ; Vogt P; Kappenberger L
    N Engl J Med; 1991 Jan; 324(1):13-7. PubMed ID: 1984159
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intraoperative and percutaneous stenting of congenital pulmonary artery and vein stenosis.
    Mendelsohn AM; Bove EL; Lupinetti FM; Crowley DC; Lloyd TR; Fedderly RT; Beekman RH
    Circulation; 1993 Nov; 88(5 Pt 2):II210-7. PubMed ID: 8222156
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Angiographic and histological results following implantation of a novel stent-on-a-wire in the animal model.
    Diletti R; Garcia-Garcia HM; van Geuns RJ; Farooq V; Bailey L; Rousselle S; Kopia G; Easterbrook W; Pomeranz M; Serruys PW
    EuroIntervention; 2012 Jul; 8(3):390-9. PubMed ID: 22377624
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 49.