These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
95 related articles for article (PubMed ID: 8615486)
1. Volume-controlled ventilation is made possible in infants by using compliant breathing circuits with large compression volume. Badgwell M; Swan J; Foster AC Anesth Analg; 1996 Apr; 82(4):719-23. PubMed ID: 8615486 [TBL] [Abstract][Full Text] [Related]
2. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation? Bachiller PR; McDonough JM; Feldman JM Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850 [TBL] [Abstract][Full Text] [Related]
3. Breathing circuit compliance and accuracy of displayed tidal volume during pressure-controlled ventilation of infants: A quality improvement project. Glenski TA; Diehl C; Clopton RG; Friesen RH Paediatr Anaesth; 2017 Sep; 27(9):935-941. PubMed ID: 28504341 [TBL] [Abstract][Full Text] [Related]
4. A comparison of three modes of ventilation with the use of an adult circle system in an infant lung model. Tobin MJ; Stevenson GW; Horn BJ; Chen EH; Hall SC; Coté CJ Anesth Analg; 1998 Oct; 87(4):766-71. PubMed ID: 9768767 [TBL] [Abstract][Full Text] [Related]
5. The effect of circuit compliance on delivered ventilation with use of an adult circle system for time cycled volume controlled ventilation using an infant lung model. Stevenson GW; Tobin MJ; Horn BJ; Sautel M; Chen EH; Hall SC; Coté CJ Paediatr Anaesth; 1998; 8(2):139-44. PubMed ID: 9549741 [TBL] [Abstract][Full Text] [Related]
6. Volume guaranteed? Accuracy of a volume-targeted ventilation mode in infants. Farrell O; Perkins EJ; Black D; Miedema M; Paul JD; Pereira-Fantini PM; Tingay DG Arch Dis Child Fetal Neonatal Ed; 2018 Mar; 103(2):F120-F125. PubMed ID: 28659362 [TBL] [Abstract][Full Text] [Related]
7. Neonatal volume guarantee ventilation: effects of spontaneous breathing, triggered and untriggered inflations. McCallion N; Lau R; Morley CJ; Dargaville PA Arch Dis Child Fetal Neonatal Ed; 2008 Jan; 93(1):F36-9. PubMed ID: 17686798 [TBL] [Abstract][Full Text] [Related]
8. An in vitro evaluation of the influence of neonatal endotracheal tube diameter and length on the work of breathing. Miyake F; Suga R; Akiyama T; Namba F Paediatr Anaesth; 2018 May; 28(5):458-462. PubMed ID: 29633434 [TBL] [Abstract][Full Text] [Related]
9. [Mechanical ventilation in an anesthetic circle system using the lowest tidal volume--studies of 3 anesthesia ventilators in a lung model and an animal experiment]. Fösel T; Schirmer U; Wick C; Pfenninger E; Siegler W; Altemeyer KH Anaesthesist; 1991 Nov; 40(11):624-8. PubMed ID: 1755533 [TBL] [Abstract][Full Text] [Related]
10. Tidal volumes for ventilated infants should be determined with a pneumotachometer placed at the endotracheal tube. Cannon ML; Cornell J; Tripp-Hamel DS; Gentile MA; Hubble CL; Meliones JN; Cheifetz IM Am J Respir Crit Care Med; 2000 Dec; 162(6):2109-12. PubMed ID: 11112123 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of a new operating room ventilator with volume-controlled ventilation: the Ohmeda 7900. Rothschiller JL; Uejima T; Dsida RM; Coté CJ Anesth Analg; 1999 Jan; 88(1):39-42. PubMed ID: 9895063 [TBL] [Abstract][Full Text] [Related]
12. Reduction of Endotracheal Tube Connector Dead Space Improves Ventilation: A Bench Test on a Model Lung Simulating an Extremely Low Birth Weight Neonate. Ivanov VA Respir Care; 2016 Feb; 61(2):155-61. PubMed ID: 26577200 [TBL] [Abstract][Full Text] [Related]
13. An adult system versus a Bain system: comparative ability to deliver minute ventilation to an infant lung model with pressure-limited ventilation. Stevenson GW; Tobin M; Horn B; Chen EH; Hall SC; Coté CJ Anesth Analg; 1999 Mar; 88(3):527-30. PubMed ID: 10071999 [TBL] [Abstract][Full Text] [Related]
14. The long Bain breathing system: an investigation into the implications of remote ventilation. Sweeting CJ; Thomas PW; Sanders DJ Anaesthesia; 2002 Dec; 57(12):1183-6. PubMed ID: 12437709 [TBL] [Abstract][Full Text] [Related]
15. Predicting the effect of fresh gas flow on tidal volume in volume-controlled mechanically ventilated dogs. Topulos SP; Topulos GP; Abelson AL; Lindsey JC; Wetmore LA Vet Anaesth Analg; 2023 Jan; 50(1):57-62. PubMed ID: 36437187 [TBL] [Abstract][Full Text] [Related]
16. Linear model and algorithm to automatically estimate the pressure limit of pressure controlled ventilation for delivering a target tidal volume. Agrò FE; Cappa P; Sciuto SA; Silvestri S J Clin Monit Comput; 2006 Feb; 20(1):1-10. PubMed ID: 16523228 [TBL] [Abstract][Full Text] [Related]
17. Randomized crossover study of neurally adjusted ventilatory assist in preterm infants. Lee J; Kim HS; Sohn JA; Lee JA; Choi CW; Kim EK; Kim BI; Choi JH J Pediatr; 2012 Nov; 161(5):808-13. PubMed ID: 22658785 [TBL] [Abstract][Full Text] [Related]
18. Feasibility of tidal volume-guided ventilation in newborn infants: a randomized, crossover trial using the volume guarantee modality. Cheema IU; Ahluwalia JS Pediatrics; 2001 Jun; 107(6):1323-8. PubMed ID: 11389251 [TBL] [Abstract][Full Text] [Related]
19. Predictable normocapnia [correction of normocapnoea] in controlled ventilation of infants with Jackson Rees or Bain system. Park JW; Chung SH; Choe YK; Kim YJ; Shin CM; Park JY Anaesthesia; 1998 Dec; 53(12):1180-4. PubMed ID: 10193221 [TBL] [Abstract][Full Text] [Related]
20. Patient-triggered ventilation: a comparison of tidal volume and chestwall and abdominal motion as trigger signals. Nikischin W; Gerhardt T; Everett R; Gonzalez A; Hummler H; Bancalari E Pediatr Pulmonol; 1996 Jul; 22(1):28-34. PubMed ID: 8856801 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]