These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 862168)

  • 1. The pulsed Doppler coronary artery catheter preliminary report of a new technique for measuring rapid changes in coronary artery flow velocity in man.
    Cole JS; Hartley CJ
    Circulation; 1977 Jul; 56(1):18-25. PubMed ID: 862168
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Coronary flow velocity dynamics in normal and diseased arteries.
    Ofili EO; Labovitz AJ; Kern MJ
    Am J Cardiol; 1993 May; 71(14):3D-9D. PubMed ID: 8488773
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transluminal, subselective measurement of coronary artery blood flow velocity and vasodilator reserve in man.
    Wilson RF; Laughlin DE; Ackell PH; Chilian WM; Holida MD; Hartley CJ; Armstrong ML; Marcus ML; White CW
    Circulation; 1985 Jul; 72(1):82-92. PubMed ID: 3159506
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Usefulness of flow reserve in the left internal mammary artery to determine graft patency to the left anterior descending coronary artery.
    Voudris V; Athanassopoulos G; Vassilikos V; Avramides D; Manginas A; Michalis A; Cokkinos DV
    Am J Cardiol; 1999 Apr; 83(8):1157-63. PubMed ID: 10215276
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Coronary blood flow velocities in humans evaluated during cardiac surgery using a 20 MHz 80 + 1 channel ultrasound pulsed Doppler velocimeter].
    Kajiya F; Tsujioka K; Tadaoka S
    J Cardiogr; 1986 Jun; 16(2):279-90. PubMed ID: 2953822
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Subselective measurement of coronary blood flow velocity using a steerable Doppler catheter.
    Sibley DH; Millar HD; Hartley CJ; Whitlow PL
    J Am Coll Cardiol; 1986 Dec; 8(6):1332-40. PubMed ID: 3537059
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of phasic blood flow velocity characteristics of arterial and venous coronary artery bypass conduits.
    Bach RG; Kern MJ; Donohue TJ; Aguirre FV; Caracciolo EA
    Circulation; 1993 Nov; 88(5 Pt 2):II133-40. PubMed ID: 8222148
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Flow capacity of internal mammary artery grafts: early restriction and later improvement assessed by Doppler guide wire. Comparison with saphenous vein grafts.
    Akasaka T; Yoshikawa J; Yoshida K; Maeda K; Hozumi T; Nasu M; Shomura T
    J Am Coll Cardiol; 1995 Mar; 25(3):640-7. PubMed ID: 7860908
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Measuring blood flow velocity in the coronary sinus with Doppler catheters].
    Tebbenjohanns J; Nitsch J; Lüderitz B
    Z Kardiol; 1992 Mar; 81(3):170-5. PubMed ID: 1585715
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prediction of the physiologic significance of coronary arterial lesions by quantitative lesion geometry in patients with limited coronary artery disease.
    Wilson RF; Marcus ML; White CW
    Circulation; 1987 Apr; 75(4):723-32. PubMed ID: 3829334
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessment of severity of coronary stenoses using a Doppler catheter. Validation of a method based on the continuity equation.
    Johnson EL; Yock PG; Hargrave VK; Srebro JP; Manubens SM; Seitz W; Ports TA
    Circulation; 1989 Sep; 80(3):625-35. PubMed ID: 2527644
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Noninvasive assessment of left internal mammary artery graft patency using transthoracic echocardiography.
    Crowley JJ; Shapiro LM
    Circulation; 1995 Nov; 92(9 Suppl):II25-30. PubMed ID: 7586418
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessment of internal mammary artery and saphenous vein graft patency and flow reserve using transthoracic Doppler echocardiography.
    Chirillo F; Bruni A; Balestra G; Cavallini C; Olivari Z; Thomas JD; Stritoni P
    Heart; 2001 Oct; 86(4):424-31. PubMed ID: 11559684
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Vascular adaptation of the internal thoracic artery graft early and late after bypass surgery.
    Walpoth BH; Schmid M; Schwab A; Bosshard A; Eckstein F; Carrel T; Hess OM
    J Thorac Cardiovasc Surg; 2008 Oct; 136(4):876-83. PubMed ID: 18954625
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Instantaneous pressure-velocity relationship of the coronary flow, alternative to coronary reserve measurement: a feasibility study and reproducibility of the method].
    Meneveau N; Di Mario C; Gil R; de Jaegere P; de Feyter PJ; Roelandt J; Serruys PW
    Arch Mal Coeur Vaiss; 1993 Jul; 86(7):975-85. PubMed ID: 8291945
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validity of catheter-tip Doppler technique in assessment of coronary flow velocity and application of spectrum analysis method.
    Yamagishi M; Hotta D; Tamai J; Nakatani S; Miyatake K
    Am J Cardiol; 1991 Apr; 67(8):758-62. PubMed ID: 2006628
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of maximal coronary flow reserve: a technique for assessing the physiologic significance of coronary arterial lesions in humans.
    Wilson RF; White CW
    Herz; 1987 Jun; 12(3):163-76. PubMed ID: 3623398
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Does coronary artery bypass surgery restore normal maximal coronary flow reserve? The effect of diffuse atherosclerosis and focal obstructive lesions.
    Wilson RF; White CW
    Circulation; 1987 Sep; 76(3):563-71. PubMed ID: 2957110
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use of sideholes for diagnostic coronary arteriography by Judkins technique in patients with ostial coronary stenosis.
    Bourdillon PD
    Cathet Cardiovasc Diagn; 1992 Dec; 27(4):259-66. PubMed ID: 1458519
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [The relation of coronary artery disease with Doppler flow velocity and resistance index in cases without significant carotid artery stenosis].
    Ulgen MS; Bilici A; Acar M; Onder H; Sucu M; Toprak N
    Anadolu Kardiyol Derg; 2001 Mar; 1(1):5-9, AXII. PubMed ID: 12122971
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.