BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 8623069)

  • 1. Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography.
    Farber GL; Place HM; Mazur RA; Jones DE; Damiano TR
    Spine (Phila Pa 1976); 1995 Jul; 20(13):1494-9. PubMed ID: 8623069
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of pedicle screw position in thoracic and lumbar spine fixation using plain radiographs and computed tomography. A prospective study of 35 patients.
    Sapkas GS; Papadakis SA; Stathakopoulos DP; Papagelopoulos PJ; Badekas AC; Kaiser JH
    Spine (Phila Pa 1976); 1999 Sep; 24(18):1926-9. PubMed ID: 10515018
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stepwise methodology for plain radiographic assessment of pedicle screw placement: a comparison with computed tomography.
    Choma TJ; Denis F; Lonstein JE; Perra JH; Schwender JD; Garvey TA; Mullin WJ
    J Spinal Disord Tech; 2006 Dec; 19(8):547-53. PubMed ID: 17146296
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation.
    Learch TJ; Massie JB; Pathria MN; Ahlgren BA; Garfin SR
    Spine (Phila Pa 1976); 2004 Apr; 29(7):767-73. PubMed ID: 15087800
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of pedicle screw placement in the deformed spine using intraoperative plain radiographs: a comparison with computerized tomography.
    Kim YJ; Lenke LG; Cheh G; Riew KD
    Spine (Phila Pa 1976); 2005 Sep; 30(18):2084-8. PubMed ID: 16166900
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Imaging assessment of lumbar pedicle screw placement: sensitivity and specificity of plain radiographs and computer axial tomography.
    Brooks D; Eskander M; Balsis S; Ordway N; Connolly P
    Spine (Phila Pa 1976); 2007 Jun; 32(13):1450-3. PubMed ID: 17545915
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of plain radiographs to identify wrong positioned free hand pedicle screw in the deformed spine.
    Piazzolla A; Montemurro V; Bizzoca D; Parato C; Carlucci S; Moretti B
    J Neurosurg Sci; 2019 Aug; 63(4):372-378. PubMed ID: 27167472
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine.
    Wiesner L; Kothe R; Schulitz KP; Rüther W
    Spine (Phila Pa 1976); 2000 Mar; 25(5):615-21. PubMed ID: 10749639
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pedicle screw placement with a free hand technique in thoracolumbar spine: is it safe?
    Karapinar L; Erel N; Ozturk H; Altay T; Kaya A
    J Spinal Disord Tech; 2008 Feb; 21(1):63-7. PubMed ID: 18418139
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Can Postoperative Radiographs Accurately Identify Screw Misplacements?
    Sarwahi V; Ayan S; Amaral T; Wendolowski S; Gecelter R; Lo Y; Thornhill B
    Spine Deform; 2017 Mar; 5(2):109-116. PubMed ID: 28259262
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical accuracy of computer-assisted two-dimensional fluoroscopy for the percutaneous placement of lumbosacral pedicle screws.
    Ravi B; Zahrai A; Rampersaud R
    Spine (Phila Pa 1976); 2011 Jan; 36(1):84-91. PubMed ID: 20595927
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical relevance of accuracy of pedicle screw placement. A computed tomographic-supported analysis.
    Schulze CJ; Munzinger E; Weber U
    Spine (Phila Pa 1976); 1998 Oct; 23(20):2215-20; discussion 2220-1. PubMed ID: 9802164
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Incidence and clinical significance of vascular encroachment resulting from freehand placement of pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws.
    Parker SL; Amin AG; Santiago-Dieppa D; Liauw JA; Bydon A; Sciubba DM; Wolinsky JP; Gokaslan ZL; Witham TF
    Spine (Phila Pa 1976); 2014 Apr; 39(8):683-7. PubMed ID: 24480963
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of pedicle screw placement with the assistance of lateral plain radiography.
    Odgers CJ; Vaccaro AR; Pollack ME; Cotler JM
    J Spinal Disord; 1996 Aug; 9(4):334-8. PubMed ID: 8877962
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of using computed tomography to identify pedicle screw placement in cadaveric human lumbar spine.
    Yoo JU; Ghanayem A; Petersilge C; Lewin J
    Spine (Phila Pa 1976); 1997 Nov; 22(22):2668-71. PubMed ID: 9399454
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Assessment of pedicle perforation by the cervical pedicle screw placement using plain radiographs: a comparison with computed tomography.
    Lee SH; Kim KT; Suk KS; Lee JH; Son ES; Kwack YH; Oh HS
    Spine (Phila Pa 1976); 2012 Feb; 37(4):280-5. PubMed ID: 21629168
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [The safety of pedicle screw fixation in the thoracic spine].
    Yalniz E; Ciftdemir M; Eşkin D; Dülger H
    Acta Orthop Traumatol Turc; 2009; 43(6):522-7. PubMed ID: 20134221
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models.
    Austin MS; Vaccaro AR; Brislin B; Nachwalter R; Hilibrand AS; Albert TJ
    Spine (Phila Pa 1976); 2002 Nov; 27(22):2503-8. PubMed ID: 12435982
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: technique and short-term complications.
    Carbone JJ; Tortolani PJ; Quartararo LG
    Spine (Phila Pa 1976); 2003 Jan; 28(1):91-7. PubMed ID: 12544964
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Percutaneous placement of pedicle screws in the lumbar spine using a bone mounted miniature robotic system: first experiences and accuracy of screw placement.
    Pechlivanis I; Kiriyanthan G; Engelhardt M; Scholz M; Lücke S; Harders A; Schmieder K
    Spine (Phila Pa 1976); 2009 Feb; 34(4):392-8. PubMed ID: 19214099
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.