BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 8625642)

  • 1. Accuracy of pulse oximetry in hypothermic neonates and infants undergoing cardiac surgery.
    Iyer P; McDougall P; Loughnan P; Mee RB; Al-Tawil K; Carlin J
    Crit Care Med; 1996 Mar; 24(3):507-11. PubMed ID: 8625642
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of peripheral perfusion on accuracy of pulse oximetry in children.
    Villanueva R; Bell C; Kain ZN; Colingo KA
    J Clin Anesth; 1999 Jun; 11(4):317-22. PubMed ID: 10470634
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Oximetry in children recovering from deep hypothermia for cardiac surgery.
    Macnab AJ; Baker-Brown G; Anderson EE
    Crit Care Med; 1990 Oct; 18(10):1066-9. PubMed ID: 2209032
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Continuous intra-arterial oximetry, pulse oximetry, and co-oximetry during cardiac surgery.
    Haessler R; Brandl F; Zeller M; Briegel J; Peter K
    J Cardiothorac Vasc Anesth; 1992 Dec; 6(6):668-73. PubMed ID: 1472661
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison of the performance of 20 pulse oximeters under conditions of poor perfusion.
    Clayton DG; Webb RK; Ralston AC; Duthie D; Runciman WB
    Anaesthesia; 1991 Jan; 46(1):3-10. PubMed ID: 1996749
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery.
    Kyriacou PA; Powell SL; Jones DP; Langford RM
    Anaesthesia; 2003 May; 58(5):422-7. PubMed ID: 12693996
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of probe design on accuracy and reliability of pulse oximetry in pediatric patients.
    Bell C; Luther MA; Nicholson JJ; Fox CJ; Hirsh JL
    J Clin Anesth; 1999 Jun; 11(4):323-7. PubMed ID: 10470635
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Low Perfusion and Missed Diagnosis of Hypoxemia by Pulse Oximetry in Darkly Pigmented Skin: A Prospective Study.
    Gudelunas MK; Lipnick M; Hendrickson C; Vanderburg S; Okunlola B; Auchus I; Feiner JR; Bickler PE
    Anesth Analg; 2024 Mar; 138(3):552-561. PubMed ID: 38109495
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Performance of transcutaneous PCO2 and pulse oximetry monitors in newborns and infants after cardiac surgery.
    Carter BG; Wiwczaruk D; Hochmann M; Osborne A; Henning R
    Anaesth Intensive Care; 2001 Jun; 29(3):260-5. PubMed ID: 11439797
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Reliability and limitations of pulse oximetry in corrective cyanotic heart surgery].
    Meier-Stauss P; Schmid ER; Weiss BM; König V; Huch R
    Anaesthesist; 1989 Jun; 38(6):302-8. PubMed ID: 2764270
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of the Masimo SET® LNCS neo peripheral pulse oximeter in cyanotic congenital heart disease.
    Griksaitis MJ; Scrimgeour GE; Pappachan JV; Baldock AJ
    Cardiol Young; 2016 Aug; 26(6):1183-6. PubMed ID: 26471067
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of pulse oximeter at the nasal septum during general anesthesia: comparison with finger oximeter.
    Oh Y; Kim DK; Ryu DK; Choi JW
    J Anesth; 2024 Jun; 38(3):364-370. PubMed ID: 38502324
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Unreliability of pulse oximetry in hypothermic children after cardiovascular surgery with deep hypothermic circulation].
    Picardo S; Di Chiara L; Averardi M; Testa G; Giamberti A; Catena G
    Minerva Anestesiol; 1998 Oct; 64(10):427-30. PubMed ID: 9857624
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of a pulse oximeter during profound hypothermia. An assessment of the Biox 3700 during induction of hypothermia before cardiac surgery in paediatric patients.
    al Khudhairi D; Prabhu R; el Sharkawy M; Burtles R
    Int J Clin Monit Comput; 1990; 7(4):217-22. PubMed ID: 2099970
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of Pulse Oximeters Intended for Hypoxemic Pediatric Patients.
    Harris BU; Char DS; Feinstein JA; Verma A; Shiboski SC; Ramamoorthy C
    Pediatr Crit Care Med; 2016 Apr; 17(4):315-20. PubMed ID: 26914626
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of a portable pulse oximeter in monitoring hypoxemic infants with cyanotic heart disease.
    Harris BU; Stewart S; Verma A; Hoen H; Stein ML; Wright G; Ramamoorthy C
    Cardiol Young; 2019 Aug; 29(8):1025-1029. PubMed ID: 31304897
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pulse oximetry in the oesophagus.
    Kyriacou PA
    Physiol Meas; 2006 Jan; 27(1):R1-35. PubMed ID: 16365505
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pulse oximeter accuracy and precision affected by sensor location in cyanotic children.
    Sedaghat-Yazdi F; Torres A; Fortuna R; Geiss DM
    Pediatr Crit Care Med; 2008 Jul; 9(4):393-7. PubMed ID: 18496398
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use of pulse oximetry to monitor venous saturation during extracorporeal life support.
    Odell RM; Doran RM; Erickson RC; Zeilinger TC; Coyle MG
    Crit Care Med; 1994 Apr; 22(4):626-32. PubMed ID: 8143472
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pulse oximetry from the nasal septum.
    Ezri T; Lurie S; Konichezky S; Soroker D
    J Clin Anesth; 1991; 3(6):447-50. PubMed ID: 1760166
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.