BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 8635949)

  • 21. Scattered radiation from linear accelerator and cobalt-60 collimator jaws.
    Ting JY; Yankelevich R; Goswami G; Fiedler JA; Houdek PV
    Int J Radiat Oncol Biol Phys; 1994 Nov; 30(4):985-92. PubMed ID: 7961003
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Monte Carlo study of photon fields from a flattening filter-free clinical accelerator.
    Vassiliev ON; Titt U; Kry SF; Pönisch F; Gillin MT; Mohan R
    Med Phys; 2006 Apr; 33(4):820-7. PubMed ID: 16696457
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Measurements of dose from secondary radiation outside a treatment field.
    Kase KR; Svensson GK; Wolbarst AB; Marks MA
    Int J Radiat Oncol Biol Phys; 1983 Aug; 9(8):1177-83. PubMed ID: 6409854
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Characterisation of in-room leakage and scattered radiation for the Varian Halcyon linear accelerator.
    Caravani K; Murry R; Healy B
    Phys Eng Sci Med; 2022 Mar; 45(1):73-81. PubMed ID: 34797532
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Head scatter off-axis for megavoltage x rays.
    Zhu TC; Bjärngard BE
    Med Phys; 2003 Apr; 30(4):533-43. PubMed ID: 12722805
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Peripheral dose from megavolt beams.
    Fraass BA; van de Geijn J
    Med Phys; 1983; 10(6):809-18. PubMed ID: 6419031
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Commissioning and dosimetric characteristics of TrueBeam system: composite data of three TrueBeam machines.
    Chang Z; Wu Q; Adamson J; Ren L; Bowsher J; Yan H; Thomas A; Yin FF
    Med Phys; 2012 Nov; 39(11):6981-7018. PubMed ID: 23127092
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Surface dose for five telecobalt machines, 6MV photon beam from four linear accelerators and a Hi-Art Tomotherapy.
    Kinhikar RA
    Technol Cancer Res Treat; 2008 Oct; 7(5):381-4. PubMed ID: 18783288
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A Monte Carlo study on internal wedges using BEAM.
    van der Zee W; Welleweerd J
    Med Phys; 2002 May; 29(5):876-85. PubMed ID: 12033584
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Measurements of in-air output ratios for a linear accelerator with and without the flattening filter.
    Zhu XR; Kang Y; Gillin MT
    Med Phys; 2006 Oct; 33(10):3723-33. PubMed ID: 17089838
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Collimator scatter in modeling radiation beam profiles.
    Rosen II; Loyd MD; Lane RG
    Med Phys; 1990; 17(3):422-8. PubMed ID: 2385199
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code.
    Sheikh-Bagheri D; Rogers DW
    Med Phys; 2002 Mar; 29(3):391-402. PubMed ID: 11930914
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Internal scatter, the unavoidable major component of the peripheral dose in photon-beam radiotherapy.
    Chofor N; Harder D; Willborn KC; Poppe B
    Phys Med Biol; 2012 Mar; 57(6):1733-43. PubMed ID: 22398213
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Leakage of the Siemens 160 MLC multileaf collimator on a dual energy linear accelerator.
    Klüter S; Sroka-Perez G; Schubert K; Debus J
    Phys Med Biol; 2011 Jan; 56(2):N29-37. PubMed ID: 21178240
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Modeling the output ratio in air for megavoltage photon beams.
    Zhu TC; Bjärngard BE; Xiao Y; Yang CJ
    Med Phys; 2001 Jun; 28(6):925-37. PubMed ID: 11439489
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Technical Report: Evaluation of peripheral dose for flattening filter free photon beams.
    Covington EL; Ritter TA; Moran JM; Owrangi AM; Prisciandaro JI
    Med Phys; 2016 Aug; 43(8):4789. PubMed ID: 27487896
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Estimation of the dose at the maze entrance for x-rays from radiotherapy linear accelerators.
    Al-Affan IA
    Med Phys; 2000 Jan; 27(1):231-8. PubMed ID: 10659762
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Clinically relevant investigation of flattening filter-free skin dose.
    Guy CL; Karki K; Sharma M; Kim S
    J Appl Clin Med Phys; 2016 Nov; 17(6):140-148. PubMed ID: 27929489
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Independent collimator dosimetry for a dual photon energy linear accelerator.
    Slessinger ED; Gerber RL; Harms WB; Klein EE; Purdy JA
    Int J Radiat Oncol Biol Phys; 1993 Oct; 27(3):681-7. PubMed ID: 8226165
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Design of a fast multileaf collimator for radiobiological optimized IMRT with scanned beams of photons, electrons, and light ions.
    Svensson R; Larsson S; Gudowska I; Holmberg R; Brahme A
    Med Phys; 2007 Mar; 34(3):877-88. PubMed ID: 17441233
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.