These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 8638226)

  • 1. The fiberoptic intraparenchymal cerebral pressure monitor in 244 patients.
    Shapiro S; Bowman R; Callahan J; Wolfla C
    Surg Neurol; 1996 Mar; 45(3):278-82. PubMed ID: 8638226
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical experience with a fiberoptic intracranial pressure monitor.
    Yablon JS; Lantner HJ; McCormack TM; Nair S; Barker E; Black P
    J Clin Monit; 1993 Jul; 9(3):171-5. PubMed ID: 8345369
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Camino intracranial pressure device in clinical practice. Assessment in a 1000 cases.
    Gelabert-González M; Ginesta-Galan V; Sernamito-García R; Allut AG; Bandin-Diéguez J; Rumbo RM
    Acta Neurochir (Wien); 2006 Apr; 148(4):435-41. PubMed ID: 16374566
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intracranial pressure monitoring: fiberoptic monitor compared with the ventricular catheter.
    Schickner DJ; Young RF
    Surg Neurol; 1992 Apr; 37(4):251-4. PubMed ID: 1595034
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The use of a fiberoptic intracranial pressure monitor in clinical practice.
    Levin AB
    Neurosurgery; 1977; 1(3):266-71. PubMed ID: 615971
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Aggressive use of ICP monitoring is safe and alters patient care.
    Eddy VA; Vitsky JL; Rutherford EJ; Morris JA
    Am Surg; 1995 Jan; 61(1):24-9. PubMed ID: 7832377
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Monitoring of brain tissue pressure with a fiberoptic device.
    Gambardella G; d'Avella D; Tomasello F
    Neurosurgery; 1992 Nov; 31(5):918-21; discussion 921-2. PubMed ID: 1436417
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fiberoptic intraparenchymal brain pressure monitoring with the Camino V420 monitor: reflections on our experience in 163 severely head-injured patients.
    Poca MA; Sahuquillo J; Arribas M; Báguena M; Amorós S; Rubio E
    J Neurotrauma; 2002 Apr; 19(4):439-48. PubMed ID: 11990350
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Camino intracranial pressure device in clinical practice: reliability, handling characteristics and complications.
    Münch E; Weigel R; Schmiedek P; Schürer L
    Acta Neurochir (Wien); 1998; 140(11):1113-9; discussion 1119-20. PubMed ID: 9870055
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of a fiberoptic intracranial pressure monitor.
    Crutchfield JS; Narayan RK; Robertson CS; Michael LH
    J Neurosurg; 1990 Mar; 72(3):482-7. PubMed ID: 2303881
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intracerebral abscess associated with the Camino intracranial pressure monitor: case report and review of the literature.
    Morton R; Lucas TH; Ko A; Browd SR; Ellenbogen RG; Chesnut RM
    Neurosurgery; 2012 Jul; 71(1):E193-8. PubMed ID: 21869723
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Complications of brain tissue pressure monitoring with a fiberoptic device.
    Bekar A; Gören S; Korfali E; Aksoy K; Boyaci S
    Neurosurg Rev; 1998; 21(4):254-9. PubMed ID: 10068186
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prolonged intracranial pressure (ICP) monitoring in non-traumatic pediatric neurosurgical diseases.
    Tamburrini G; Di Rocco C; Velardi F; Santini P
    Med Sci Monit; 2004 Apr; 10(4):MT53-63. PubMed ID: 15039654
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Monitoring of intracranial pressure with intraparenchymal fiberoptic transducer. Technical aspects and clinical reliability].
    Artru F; Terrier A; Gibert I; Messaoudi K; Charlot M; Naous H; Jourdan C
    Ann Fr Anesth Reanim; 1992; 11(4):424-9. PubMed ID: 1416275
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Protocol based invasive intracranial pressure monitoring in acute liver failure: feasibility, safety and impact on management.
    Rajajee V; Fontana RJ; Courey AJ; Patil PG
    Crit Care; 2017 Jul; 21(1):178. PubMed ID: 28693567
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical evaluation of the InnerSpace fibreoptic intracranial pressure monitoring device.
    Holzschuh M; Woertgen C; Metz C; Brawanski A
    Brain Inj; 1998 Mar; 12(3):191-8. PubMed ID: 9547949
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Complications of intracranial pressure monitoring in children with head trauma.
    Anderson RC; Kan P; Klimo P; Brockmeyer DL; Walker ML; Kestle JR
    J Neurosurg; 2004 Aug; 101(1 Suppl):53-8. PubMed ID: 16206972
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intracranial Pressure Monitoring in Acute Liver Failure: Institutional Case Series.
    Maloney PR; Mallory GW; Atkinson JL; Wijdicks EF; Rabinstein AA; Van Gompel JJ
    Neurocrit Care; 2016 Aug; 25(1):86-93. PubMed ID: 26966022
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Complications following intracranial pressure monitoring in children: a 6-year single-center experience.
    Ma R; Rowland D; Judge A; Calisto A; Jayamohan J; Johnson D; Richards P; Magdum S; Wall S
    J Neurosurg Pediatr; 2018 Mar; 21(3):278-283. PubMed ID: 29303458
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Risk factors of intracranial pressure monitoring in children with fiberoptic devices: a critical review.
    Jensen RL; Hahn YS; Ciro E
    Surg Neurol; 1997 Jan; 47(1):16-22. PubMed ID: 8986159
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.