These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

61 related articles for article (PubMed ID: 8644229)

  • 1. A cooling jacket to reduce tubular damage during kidney transplantation: evaluation of a prototype in the pig model.
    Desgrandchamps F; Eugene M; Tuchschmid Y; Muller F; Le Moyec L; Teillac P; Bedrossian J; Idatte JM; Le Duc A
    Transplant Proc; 1996 Feb; 28(1):293-6. PubMed ID: 8644229
    [No Abstract]   [Full Text] [Related]  

  • 2. [Cooling shell in renal transplantation. Thermometric evaluation of a prototype].
    Desgrandchamps F; Eugene M; Tuchschmid Y; Muller F; Teillac P; Idatte JM; Le Duc A
    Prog Urol; 1996 Feb; 6(1):25-9. PubMed ID: 8624524
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Experimental study of a cooling jacket in renal transplantation.
    Planet M; Desgrandchamps F; Hauet T; Gourmel B; Goujon B; Carretier M; Teillac P; Grise P; Le Duc A
    Transplant Proc; 2000 Mar; 32(2):493-5. PubMed ID: 10715493
    [No Abstract]   [Full Text] [Related]  

  • 4. A cooling jacket to reduce renal damage during transplantation.
    Stephenson RN
    Br J Urol; 1993 Apr; 71(4):384-7. PubMed ID: 8499978
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Efficiency of trimetazidine in renal dysfunction secondary to cold ischemia-reperfusion injury: a proposed addition to University of Wisconsin solution.
    Hauet T; Tallineau C; Goujon JM; Carretier M; Eugene M; Tillement JP
    Cryobiology; 1998 Nov; 37(3):231-44. PubMed ID: 9787068
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reducing renal injury during transplantation.
    Forsythe JL; Dunnigan PM; Proud G; Lennard TW; Taylor RM
    Br J Surg; 1989 Oct; 76(10):999-1001. PubMed ID: 2597963
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of injury preservation in pig kidney cold storage by proton nuclear magnetic resonance spectroscopy of urine.
    Hauet T; Mothes D; Goujon JM; Caritez JC; Carretier M; Eugene M
    J Urol; 1997 Mar; 157(3):1155-60. PubMed ID: 9072561
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Detection of preservation-induced tubular damage by fine needle aspiration and tetrazolium-based quantitative cell viability assay.
    Yussim A; Sandbank J; Nakache R; Shaharabani E; Shmueli D; Lustig S; Bar-Nathan N; Geyer E; Sobolev V; Or H
    Transplant Proc; 1994 Aug; 26(4):2379-81. PubMed ID: 8066780
    [No Abstract]   [Full Text] [Related]  

  • 9. The modification of renal transplantation with the usage of own polyethylene receptacle.
    Pupka A; Chudoba P; Patrzałek D; Janczak D; Szyber P
    Polim Med; 2003; 33(3):33-7. PubMed ID: 14696523
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Function and quality of kidneys after cold storage, machine perfusion, or retrograde oxygen persufflation: results from a porcine autotransplantation model.
    Treckmann J; Nagelschmidt M; Minor T; Saner F; Saad S; Paul A
    Cryobiology; 2009 Aug; 59(1):19-23. PubMed ID: 19345683
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Experimental renal preservation by normothermic resuscitation perfusion with autologous blood.
    Bagul A; Hosgood SA; Kaushik M; Kay MD; Waller HL; Nicholson ML
    Br J Surg; 2008 Jan; 95(1):111-8. PubMed ID: 17696214
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A modified University of Wisconsin preservation solution with high-NA+ low-K+ content reduces reperfusion injury of the pig kidney graft.
    Hauet T; Han Z; Doucet C; Ramella-Virieux S; Hadj Aïssa A; Carretier M; Papadopoulos V
    Transplantation; 2003 Jul; 76(1):18-27. PubMed ID: 12865781
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of retrieval conditions on renal medulla injury: evaluation by proton NMR spectroscopy in an isolated perfused pig kidney model.
    Hauet T; Gibelin H; Richer JP; Godart C; Eugene M; Carretier M
    J Surg Res; 2000 Sep; 93(1):1-8. PubMed ID: 10945936
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Clinical evaluation of donor renal artery reconstruction in kidney transplantation.
    Miura M; Seki T; Harada H; Chikaraishi T; Nonomura K; Koyanagi T
    Transplant Proc; 1996 Jun; 28(3):1611-3. PubMed ID: 8658807
    [No Abstract]   [Full Text] [Related]  

  • 15. Assessment of functional activity of cold-stored kidney transplant by proton magnetic resonance spectroscopy.
    Hauet T; Mothes D; Goujon JM; Badia P; Carretier M; Caritez JC; Robert R; Tallineau C; Eugene M
    Transplant Proc; 1996 Oct; 28(5):2896-8. PubMed ID: 8908115
    [No Abstract]   [Full Text] [Related]  

  • 16. Evaluation of the ischemic protection efficacy of a laparoscopic renal cooling device using renal transplantation viability assessment criteria in a porcine model.
    Navarro AP; Sohrabi S; Colechin E; Griffiths C; Talbot D; Soomro NA
    J Urol; 2008 Mar; 179(3):1184-9. PubMed ID: 18206167
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Noninvasive monitoring of citrate, acetate, lactate, and renal medullary osmolyte excretion in urine as biomarkers of exposure to ischemic reperfusion injury.
    Hauet T; Baumert H; Gibelin H; Hameury F; Goujon JM; Carretier M; Eugene M
    Cryobiology; 2000 Dec; 41(4):280-91. PubMed ID: 11222025
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hypothermic renal preservation with a sucrose/ polyethylene glycol solution in a rabbit renal transplant model.
    Fuller BJ; Shurey C; Lane N; Petrenko A; Green C
    Cryo Letters; 2006; 27(2):127-32. PubMed ID: 16794744
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Storage by continuous hypothermic perfusion for kidney harvested from hemodynamically unstable donors.
    Kwiatkowski A; Danielewicz R; Polak W; Michalak G; Paczek L; Wałaszewski J; Rowiński W
    Transplant Proc; 1996 Feb; 28(1):306-7. PubMed ID: 8644234
    [No Abstract]   [Full Text] [Related]  

  • 20. Improved kidney graft function after preservation using a novel hypothermic machine perfusion device.
    Maathuis MH; Manekeller S; van der Plaats A; Leuvenink HG; 't Hart NA; Lier AB; Rakhorst G; Ploeg RJ; Minor T
    Ann Surg; 2007 Dec; 246(6):982-8; discussion 989-91. PubMed ID: 18043100
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.