These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

249 related articles for article (PubMed ID: 8644637)

  • 1. Comparison of the diagnostic potential of four echocardiographic stress tests shortly after acute myocardial infarction: submaximal exercise, transesophageal atrial pacing, dipyridamole, and dobutamine-atropine.
    Schröder K; Völler H; Dingerkus H; Münzberg H; Dissmann R; Linderer T; Schultheiss HP
    Am J Cardiol; 1996 May; 77(11):909-14. PubMed ID: 8644637
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Detection of coronary artery disease by digital stress echocardiography: comparison of exercise, transesophageal atrial pacing and dipyridamole echocardiography.
    Marangelli V; Iliceto S; Piccinni G; De Martino G; Sorgente L; Rizzon P
    J Am Coll Cardiol; 1994 Jul; 24(1):117-24. PubMed ID: 8006254
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The atropine factor in pharmacologic stress echocardiography. Echo Persantine (EPIC) and Echo Dobutamine International Cooperative (EDIC) Study Groups.
    Pingitore A; Picano E; Colosso MQ; Reisenhofer B; Gigli G; Lucarini AR; Petix N; Previtali M; Bigi R; Chiarandà G; Minardi G; de Alcantara M; Lowenstein J; Sclavo MG; Palmieri C; Galati A; Seveso G; Heyman J; Mathias W; Casazza F; Sicari R; Raciti M; Landi P; Marzilli M
    J Am Coll Cardiol; 1996 Apr; 27(5):1164-70. PubMed ID: 8609337
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Nonexercise stress transthoracic echocardiography: transesophageal atrial pacing versus dobutamine stress.
    Lee CY; Pellikka PA; McCully RB; Mahoney DW; Seward JB
    J Am Coll Cardiol; 1999 Feb; 33(2):506-11. PubMed ID: 9973032
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dipyridamole and dobutamine-atropine stress echocardiography in the diagnosis of coronary artery disease. Comparison with exercise stress test, analysis of agreement, and impact of antianginal treatment.
    San Román JA; Vilacosta I; Castillo JA; Rollán MJ; Peral V; Sánchez-Harguindey L; Fernández-Avilés F
    Chest; 1996 Nov; 110(5):1248-54. PubMed ID: 8915229
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [The echo-stress test with dipyridamole-atropine on the 3rd-5th day of an uncomplicated acute myocardial infarct for risk stratification and early discharge].
    Astarita C; Liguori E; Stella P; Rumolo S; Gambardella S; Severino S; Caso P; Maresca FS
    Ital Heart J Suppl; 2000 Apr; 1(4):512-9. PubMed ID: 10832137
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of exercise, dobutamine-atropine and dipyridamole-atropine stress echocardiography in detecting coronary artery disease.
    Nedeljkovic I; Ostojic M; Beleslin B; Djordjevic-Dikic A; Stepanovic J; Nedeljkovic M; Stojkovic S; Stankovic G; Saponjski J; Petrasinovic Z; Giga V; Mitrovic P
    Cardiovasc Ultrasound; 2006 May; 4():22. PubMed ID: 16672046
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Head-to-head comparison of dipyridamole, dobutamine and pacing stress echocardiography for the detection of myocardial ischemia in an animal model of coronary artery stenosis.
    Schmidt A; de Almeida-Filho OC; Ayres-Neto EM; Carneiro JJ; Marin-Neto JA; Maciel BC
    Braz J Med Biol Res; 2001 Jul; 34(7):903-11. PubMed ID: 11449309
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dobutamine-atropine stress echocardiography and dipyridamole sestamibi scintigraphy for the detection of coronary artery disease: limitations and concordance.
    Smart SC; Bhatia A; Hellman R; Stoiber T; Krasnow A; Collier BD; Sagar KB
    J Am Coll Cardiol; 2000 Oct; 36(4):1265-73. PubMed ID: 11028482
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Age-related determinants of outcome after acute myocardial infarction: a dobutamine-atropine stress echocardiographic study.
    Smart S; Sagar K; Tresch D
    J Am Geriatr Soc; 2002 Jul; 50(7):1176-85. PubMed ID: 12133010
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Safety of dobutamine-atropine stress echocardiography: A prospective experience of 4,033 consecutive studies.
    Mathias W; Arruda A; Santos FC; Arruda AL; Mattos E; Osório A; Campos O; Gil M; Andrade JL; Carvalho AC
    J Am Soc Echocardiogr; 1999 Oct; 12(10):785-91. PubMed ID: 10511646
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of bicycle, heavy isometric, dipyridamole-atropine and dobutamine stress echocardiography for diagnosis of myocardial ischemia.
    Loimaala A; Groundstroem K; Pasanen M; Oja P; Vuori I
    Am J Cardiol; 1999 Dec; 84(12):1396-400. PubMed ID: 10606111
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dipyridamole-dobutamine stress echocardiography for the detection of myocardial ischemia in patients with hypertension.
    Milosavljevic J; Ostojic M; Marinkovic J
    Herz; 2005 May; 30(3):215-22. PubMed ID: 15902372
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Safety and accuracy of dobutamine-atropine stress echocardiography for the detection of residual stenosis of the infarct-related artery and multivessel disease during the first week after acute myocardial infarction.
    Smart SC; Knickelbine T; Stoiber TR; Carlos M; Wynsen JC; Sagar KB
    Circulation; 1997 Mar; 95(6):1394-401. PubMed ID: 9118505
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Feasibility and safety of dobutamine/atropine echocardiography following acute myocardial infarct].
    Paventi S; Biferali F; Ciavatti M; Falcone M; Palamara A
    Minerva Cardioangiol; 1997 Oct; 45(10):483-8. PubMed ID: 9489317
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Integrated evaluation of relation between coronary lesion features and stress echocardiography results: the importance of coronary lesion morphology.
    Beleslin BD; Ostojic M; Djordjevic-Dikic A; Babic R; Nedeljkovic M; Stankovic G; Stojkovic S; Marinkovic J; Nedeljkovic I; Stepanovic J; Saponjski J; Petrasinovic Z; Nedeljkovic S; Kanjuh V
    J Am Coll Cardiol; 1999 Mar; 33(3):717-26. PubMed ID: 10080473
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dipyridamole-atropine stress echocardiography versus exercise SPECT scintigraphy for detection of coronary artery disease in hypertensives with positive exercise test.
    Astarita C; Pálinkás A; Nicolai E; Maresca FS; Varga A; Picano E
    J Hypertens; 2001 Mar; 19(3):495-502. PubMed ID: 11288820
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transesophageal atrial pacing or pharmacologic stress testing in detection of coronary artery disease in patients who are unable to undergo exercise stress testing.
    Kotler MN; Jacobs LE
    J Am Coll Cardiol; 1990 Nov; 16(5):1154-7. PubMed ID: 2229762
    [No Abstract]   [Full Text] [Related]  

  • 19. Transesophageal dobutamine-atropine stress echocardiography: diagnostic accuracy for coronary stenosis detection and localization.
    Shahi M; Radhakrishnan S; Sinha N; Shrivastava S
    Int J Cardiol; 1996 Oct; 56(2):185-92. PubMed ID: 8894791
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pharmacological stress echocardiography in the diagnosis of coronary artery disease and myocardial ischaemia: a comparison between dobutamine and dipyridamole.
    Salustri A; Fioretti PM; McNeill AJ; Pozzoli MM; Roelandt JR
    Eur Heart J; 1992 Oct; 13(10):1356-62. PubMed ID: 1396808
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.