BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 8644925)

  • 1. Failure of 29Si NMR to detect increased blood silicon levels in silicone gel breast implant recipients.
    Macdonald P; Plavac N; Peters W; Lugowski S; Smith D
    Anal Chem; 1995 Oct; 67(20):3799-801. PubMed ID: 8644925
    [TBL] [Abstract][Full Text] [Related]  

  • 2. 29Si NMR and blood silicon levels in silicone gel breast implant recipients.
    Taylor RB; Kennan JJ
    Magn Reson Med; 1996 Sep; 36(3):498-501. PubMed ID: 8875426
    [No Abstract]   [Full Text] [Related]  

  • 3. Do patients with silicone-gel breast implants have elevated levels of blood silicon compared with control patients?
    Peters W; Smith D; Lugowski S; McHugh A; Baines C
    Ann Plast Surg; 1995 Apr; 34(4):343-7. PubMed ID: 7793777
    [TBL] [Abstract][Full Text] [Related]  

  • 4. High resolution solid-state 29Si NMR spectroscopy of silicone gels used to fill breast prostheses.
    Dorne L; Alikacem N; Guidoin R; Auger M
    Magn Reson Med; 1995 Oct; 34(4):548-54. PubMed ID: 8524023
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Silicon assays in women with and without silicone gel breast implants--a review.
    Peters W; Smith D; Lugowski S
    Ann Plast Surg; 1999 Sep; 43(3):324-30. PubMed ID: 10490190
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Elevated serum silicon levels in women with silicone gel breast implants.
    Teuber SS; Saunders RL; Halpern GM; Brucker RF; Conte V; Goldman BD; Winger EE; Wood WG; Gershwin ME
    Biol Trace Elem Res; 1995 May; 48(2):121-30. PubMed ID: 7662498
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Silicon and silicone levels in patients with silicone implants.
    Peters W; Smith D; Lugowski S; McHugh A; MacDonald P; Baines C
    Curr Top Microbiol Immunol; 1996; 210():39-48. PubMed ID: 8565583
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Silicon-29 nuclear magnetic resonance spectroscopy detection limits.
    Knight CT; Kinrade SD
    Anal Chem; 1999 Jan; 71(1):265-7. PubMed ID: 9921133
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analysis of periprosthetic capsular tissue from women with silicone breast implants by magic-angle spinning NMR.
    Garrido L; Young VL
    Magn Reson Med; 1999 Sep; 42(3):436-41. PubMed ID: 10467287
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Liquid- and solid-state high-resolution NMR methods for the investigation of aging processes of silicone breast implants.
    Birkefeld AB; Bertermann R; Eckert H; Pfleiderer B
    Biomaterials; 2003 Jan; 24(1):35-46. PubMed ID: 12417176
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Serum silicon levels are elevated in women with silicone gel implants.
    Teuber SS; Saunders RL; Halpern GM; Brucker RF; Conte V; Goldman BD; Winger EE; Wood WG; Gershwin ME
    Curr Top Microbiol Immunol; 1996; 210():59-65. PubMed ID: 8565589
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Migration and accumulation of silicone in the liver of women with silicone gel-filled breast implants.
    Pfleiderer B; Garrido L
    Magn Reson Med; 1995 Jan; 33(1):8-17. PubMed ID: 7891539
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vivo degradation of silicones.
    Garrido L; Pfleiderer B; Papisov M; Ackerman JL
    Magn Reson Med; 1993 Jun; 29(6):839-43. PubMed ID: 8350731
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A study of the aging of silicone breast implants using 29Si, 1H relaxation and DSC measurements.
    Birkefeld AB; Eckert H; Pfleiderer B
    Biomaterials; 2004 Aug; 25(18):4405-13. PubMed ID: 15046931
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Migration and biodegradation of free silicone from silicone gel-filled implants after long-term implantation.
    Pfleiderer B; Ackerman JL; Garrido L
    Magn Reson Med; 1993 Nov; 30(5):534-43. PubMed ID: 8259053
    [TBL] [Abstract][Full Text] [Related]  

  • 16. 29Si and 27Al magic-angle spinning nuclear magnetic resonance of sialon X-phase.
    Smith ME
    Solid State Nucl Magn Reson; 1994 Apr; 3(2):111-4. PubMed ID: 7834312
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analysis of silicon levels in capsules of gel and saline breast implants and of penile prostheses.
    Peters W; Smith D; Lugowski S; McHugh A; Keresteci A; Baines C
    Ann Plast Surg; 1995 Jun; 34(6):578-84. PubMed ID: 7661533
    [TBL] [Abstract][Full Text] [Related]  

  • 18. 29Si and 27Al MAS NMR spectra of mullites from different kaolinites.
    He H; Guo J; Zhu J; Yuan P; Hu C
    Spectrochim Acta A Mol Biomol Spectrosc; 2004 Apr; 60(5):1061-4. PubMed ID: 15084323
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 29Si imaging of silicone breast implants and intraocular silicone oil.
    Haselhorst R; Scheffler K; Faletti L; Kaspar A; PrĂ¼nte C; Seelig J
    Magn Reson Med; 1998 Jul; 40(1):170-4. PubMed ID: 9660568
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Silicone-specific blood lymphocyte response in women with silicone breast implants.
    Ojo-Amaize EA; Conte V; Lin HC; Brucker RF; Agopian MS; Peter JB
    Clin Diagn Lab Immunol; 1994 Nov; 1(6):689-95. PubMed ID: 8556522
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.