145 related articles for article (PubMed ID: 8651809)
1. Cannulation of neonates for venovenous extracorporeal life support.
Peek GJ; Firmin RK; Moore HM; Sosnowski AW
Ann Thorac Surg; 1996 Jun; 61(6):1851-2. PubMed ID: 8651809
[TBL] [Abstract][Full Text] [Related]
2. Venovenous compares favorably with venoarterial access for extracorporeal membrane oxygenation in neonatal respiratory failure.
Delius R; Anderson H; Schumacher R; Shapiro M; Otsu T; Toft K; Hirsch J; Bartlett R
J Thorac Cardiovasc Surg; 1993 Aug; 106(2):329-38. PubMed ID: 8341073
[TBL] [Abstract][Full Text] [Related]
3. Percutaneous cannulation for pediatric venovenous extracorporeal life support.
Foley DS; Swaniker F; Pranikoff T; Bartlett RH; Hirschl RB
J Pediatr Surg; 2000 Jun; 35(6):943-7. PubMed ID: 10873041
[TBL] [Abstract][Full Text] [Related]
4. Percutaneous access for venovenous extracorporeal life support in neonates.
Reickert CA; Schreiner RJ; Bartlett RH; Hirschl RB
J Pediatr Surg; 1998 Feb; 33(2):365-9. PubMed ID: 9498419
[TBL] [Abstract][Full Text] [Related]
5. Venovenous extracorporeal life support via percutaneous cannulation in 94 patients.
Pranikoff T; Hirschl RB; Remenapp R; Swaniker F; Bartlett RH
Chest; 1999 Mar; 115(3):818-22. PubMed ID: 10084497
[TBL] [Abstract][Full Text] [Related]
6. Use of two-dimensional and contrast echocardiography for venous cannula placement in venovenous extracorporeal life support.
Stewart DL; Sobczyk WL; Bond SJ; Cook LN
ASAIO J; 1996; 42(3):142-5. PubMed ID: 8725678
[TBL] [Abstract][Full Text] [Related]
7. Use of a 12 French double-lumen catheter in a newborn supported with extracorporeal membrane oxygenation.
Perreault T; Mullahoo K; Morneault L; Johnston A; Adolph V
ASAIO J; 1994; 40(1):100-2. PubMed ID: 8186483
[TBL] [Abstract][Full Text] [Related]
8. Initial experience with single cannulation for venovenous extracorporeal oxygenation in adults.
Bermudez CA; Rocha RV; Sappington PL; Toyoda Y; Murray HN; Boujoukos AJ
Ann Thorac Surg; 2010 Sep; 90(3):991-5. PubMed ID: 20732530
[TBL] [Abstract][Full Text] [Related]
9. Morbidity and mortality associated with large-bore percutaneous venovenous bypass cannulation for 312 orthotopic liver transplantations.
Budd JM; Isaac JL; Bennett J; Freeman JW
Liver Transpl; 2001 Apr; 7(4):359-62. PubMed ID: 11303297
[TBL] [Abstract][Full Text] [Related]
10. Complications associated with percutaneous placement of venous return cannula for venovenous bypass in adult orthotopic liver transplantation.
Sakai T; Planinsic RM; Hilmi IA; Marsh JW
Liver Transpl; 2007 Jul; 13(7):961-5. PubMed ID: 17600351
[TBL] [Abstract][Full Text] [Related]
11. Primary use of the venovenous approach for extracorporeal membrane oxygenation in pediatric acute respiratory failure.
Pettignano R; Fortenberry JD; Heard ML; Labuz MD; Kesser KC; Tanner AJ; Wagoner SF; Heggen J
Pediatr Crit Care Med; 2003 Jul; 4(3):291-8. PubMed ID: 12831409
[TBL] [Abstract][Full Text] [Related]
12. Insertion of bicaval dual-lumen cannula via the left internal jugular vein for extracorporeal membrane oxygenation.
Abrams D; Brodie D; Javidfar J; Brenner K; Wang D; Zwischenberger J; Sonett J; Bacchetta M
ASAIO J; 2012; 58(6):636-7. PubMed ID: 23103697
[TBL] [Abstract][Full Text] [Related]
13. Non-cuffed dual lumen catheters in the external jugular veins versus other central veins for hemodialysis patients.
Moini M; Rasouli MR; Kenari MM; Mahmoodi HR
Saudi J Kidney Dis Transpl; 2009 Jan; 20(1):44-8. PubMed ID: 19112218
[TBL] [Abstract][Full Text] [Related]
14. Cannulation of the internal jugular vein: comparison of the classic Seldinger technique and an ultrasound guided method.
Conz PA; Dissegna D; Rodighiero MP; La Greca G
J Nephrol; 1997; 10(6):311-3. PubMed ID: 9442443
[TBL] [Abstract][Full Text] [Related]
15. Augmented venous access in the problematic ECMO patient: a case report.
Ford EG; Atkinson JB
J Pediatr Surg; 1992 Apr; 27(4):527-8. PubMed ID: 1522474
[TBL] [Abstract][Full Text] [Related]
16. [A reliable method for internal jugular vein catheterization for neonates and infants using a small-caliber Doppler probe].
Kayashima K; Fukutome T
Masui; 1996 Nov; 45(11):1424-9. PubMed ID: 8953883
[TBL] [Abstract][Full Text] [Related]
17. A pilot/introducer needle for central vein cannulation.
Suzuki T; Kanazawa M; Kinefuchi Y; Fukuyama H; Takiguchi M; Yamamoto M; Abe K; Okuda Y
Tokai J Exp Clin Med; 1995 Dec; 20(4-6):223-6. PubMed ID: 8956464
[TBL] [Abstract][Full Text] [Related]
18. Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients.
Karakitsos D; Labropoulos N; De Groot E; Patrianakos AP; Kouraklis G; Poularas J; Samonis G; Tsoutsos DA; Konstadoulakis MM; Karabinis A
Crit Care; 2006; 10(6):R162. PubMed ID: 17112371
[TBL] [Abstract][Full Text] [Related]
19. Ultrasound-guided internal jugular vein cannulation.
Movahed MR
N Engl J Med; 2010 Aug; 363(8):796; author reply 796-7. PubMed ID: 20842792
[No Abstract] [Full Text] [Related]
20. [Decreasing iatrogenic complications during internal jugular vein catheterization by using a shorter guide needle].
Pérez Moreno J; Rodríguez Navarro M; Padilla Rodríguez J; Cantos Gómez E; Cura Iglesias S; Cutillas Aulló M; Sanz Campillo J
Rev Esp Anestesiol Reanim; 2001 Mar; 48(3):156. PubMed ID: 11333802