These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
23. Development of intimal hyperplasia in six different vascular prostheses. Ao PY; Hawthorne WJ; Vicaretti M; Fletcher JP Eur J Vasc Endovasc Surg; 2000 Sep; 20(3):241-9. PubMed ID: 10986022 [TBL] [Abstract][Full Text] [Related]
24. Fibrinogen matrix deposited on the surface of biomaterials acts as a natural anti-adhesive coating. Safiullin R; Christenson W; Owaynat H; Yermolenko IS; Kadirov MK; Ros R; Ugarova TP Biomaterials; 2015 Oct; 67():151-9. PubMed ID: 26210181 [TBL] [Abstract][Full Text] [Related]
25. A compliant Corethane/Dacron composite vascular prosthesis. Comparison with 4-mm ePTFE grafts in a canine model. Wilson GJ; MacGregor DC; Klement P; Weber BA; Binnington AG; Pinchuk L ASAIO J; 1993; 39(3):M526-31. PubMed ID: 8268591 [TBL] [Abstract][Full Text] [Related]
26. Early attachment of platelets, leukocytes, and fibrinogen in endothelial cell seeded Dacron grafts. Jensen N; Lindblad B; Ljungberg J; Leide S; Bergqvist D Ann Vasc Surg; 1996 Nov; 10(6):530-6. PubMed ID: 8989969 [TBL] [Abstract][Full Text] [Related]
27. Small-caliber heparin-coated ePTFE grafts reduce platelet deposition and neointimal hyperplasia in a baboon model. Lin PH; Chen C; Bush RL; Yao Q; Lumsden AB; Hanson SR J Vasc Surg; 2004 Jun; 39(6):1322-8. PubMed ID: 15192575 [TBL] [Abstract][Full Text] [Related]
29. Detection and measurement of a cellular immune-reactivity towards polyester and polytetrafluoroethylene grafts. Leukocyte adherence inhibition test. Cavallini G; Lanfredi M; Lodi M; Govoni M; Pampolini M Acta Chir Scand; 1987 Mar; 153(3):179-84. PubMed ID: 2955626 [TBL] [Abstract][Full Text] [Related]
30. Comparison of fluoropolymer passivated Dacron and polytetrafluoroethylene grafts in a sheep model. Sardelic F; Fletcher JP; Ao PY; Bilous M Cardiovasc Surg; 1994 Apr; 2(2):237-41. PubMed ID: 8049954 [TBL] [Abstract][Full Text] [Related]
31. Effect of albumin coating on the in vitro blood compatibility of Dacron arterial prostheses. Kottke-Marchant K; Anderson JM; Umemura Y; Marchant RE Biomaterials; 1989 Apr; 10(3):147-55. PubMed ID: 2524222 [TBL] [Abstract][Full Text] [Related]
33. The development of endotension is associated with increased transmission of pressure and serous components in porous expanded polytetrafluoroethylene stent-grafts: characterization using a canine model. Trocciola SM; Dayal R; Chaer RA; Lin SC; DeRubertis B; Ryer EJ; Hynececk RL; Pierce MJ; Prince M; Badimon J; Marin ML; Fuster V; Kent KC; Faries PL J Vasc Surg; 2006 Jan; 43(1):109-16. PubMed ID: 16414397 [TBL] [Abstract][Full Text] [Related]
34. The influence of platelet-graft interaction on platelet survival in patients with aortobifemoral Dacron grafts. Kotzé HF; Heyns AD; Nel CJ; Roodt JP; Herbst CP; Badenhorst PN; Lötter MG S Afr Med J; 1992 Jan; 81(1):27-31. PubMed ID: 1530891 [TBL] [Abstract][Full Text] [Related]
35. The systemic activation of platelets by Dacron grafts. Shoenfeld NA; Connolly R; Ramberg K; Valeri CR; Eldrup-Jorgensen J; Callow AD Surg Gynecol Obstet; 1988 May; 166(5):454-7. PubMed ID: 2966442 [TBL] [Abstract][Full Text] [Related]
36. Dacron versus polytetrafluoroethylene for Y-aortic bifurcation grafts: a six-year prospective, randomized trial. Polterauer P; Prager M; Hölzenbein T; Karner J; Kretschmer G; Schemper M Surgery; 1992 Jun; 111(6):626-33. PubMed ID: 1534424 [TBL] [Abstract][Full Text] [Related]
37. Experimental and clinical experience with a gelatin impregnated Dacron prosthesis. Drury JK; Ashton TR; Cunningham JD; Maini R; Pollock JG Ann Vasc Surg; 1987 Dec; 1(5):542-7. PubMed ID: 2462443 [TBL] [Abstract][Full Text] [Related]
38. Dual biofunctional polymer modifications to address endothelialization and smooth muscle cell integration of ePTFE vascular grafts. Bastijanic JM; Kligman FL; Marchant RE; Kottke-Marchant K J Biomed Mater Res A; 2016 Jan; 104(1):71-81. PubMed ID: 26177606 [TBL] [Abstract][Full Text] [Related]
39. Platelet and coagulation factor variations induced in vitro by polyethylene terephthalate (Dacron) coated with pyrolytic carbon. Cenni E; Arciola CR; Ciapetti G; Granchi D; Savarino L; Stea S; Cavedagna D; Curti T; Falsone G; Pizzoferrato A Biomaterials; 1995 Sep; 16(13):973-6. PubMed ID: 8580259 [TBL] [Abstract][Full Text] [Related]